Loading...
BLD20171730 (2)04 EDM CITY OF EDMONDS 121 5TH AVENUE NORTH - EDMONDS, WA 98020 PHONE: (425) 771-0220 - FAX: (425) 771-0221 Expiration Date: Parcel No: 27043000201700 SELECT HOMES INC. ADVANCED PLUMBING LLC ADVANCED PLUMBING LLC C/O RANDY & JUDY CLARK C/O THOMAS GILL C/O THOMAS GILL 16531 13TH AVE W SUITE A107 1822 BICKFORD AVE #D 1822 BICKFORD AVE #D LYNNWOOD, WA 98036- SNOHOMISH, WA 98290 SNOHOMISH, WA 98290 (206)963-3787 (425)348-5100 (425)348-5100 LICENSE #: ADVANP1838JO EXP:04/20/2019 FIRE SUPPRESSION SYSTEM FOR NEW SFR VALUATION: $0 PERMIT TYPE: Residential PERMIT GROUP: 30 - Fire Sprinkler-� GRADING: N CYDS: 0 TYPE OF CONSTRUCTION: RETAINING WALL ROCKERY: OCCUPANT GROUP: OCCUPANT LOAD: FENCE: ( 0 X 0 FT.) CODE: 2015 OTHER: ------- OTHER DESC: ZONE: NUMBER OF STORIES: 0 VESTED DATE: NUMBER OF DWELLING UNITS: 0 ILOT # : BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 BEDROOMS:0 BATHROOMS:0 BEDROOMS:0 BATHROOMS:0 FRONT1 0 REAR SETBACK ;. REQUIRED: PROPOSED: 11REQUIRED: PROPOSED: REQUIRED: PROPOSED: HEIGHT ALLOWED:O PROPOSED:O REQUIRED: PROPOSED: SETBACK NOTES: I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF, WASHINGTON RELATING TO WORKMEN'S COMPENSATION INSURANCE AND RCW 18:27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. Signature Print Name ATTENTION Released By %iie�.x�cuat / IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. UBC109/ IBCI 10/ IRCI 10. v FIRE APPLICANT ASSESSOR CITY STATUS: ISSUED BLD20171730 • Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Check the job card for all required City inspections including final project approval and final occupancy inspections. • Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable. • Approval ofany plat or plan containing provisions which do not comply with city code and for which avariance has not been specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision of city code or state law does not approve any items not to code specification. • SoundNoise originating from temporary construction sites as a result ofconstruction activity are exempt fi•onn the noise limits of FCC Chapter 5.30 only during the homy of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits ofChapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. • Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold hannless the City of Edmonds, Washington, its officials, employees, and agents fi•om any and all claims for damages of whatever nature, arising directly or indirectly from the issuance for this permit. Issuance ofthis permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT TIME LIMIT: SEE ECDC 19.00.005(A)(6) j BUILDING :ENGINEERING (425) 771-0220 EXT. 1326 j Go to: www.edmondswa.gov 2. Then: Services 3. Then: Permits/Development 4. Then: Online Permit Info 5: If you don't have one already, create a login (upper right hand corner) ,6: Schedule vour inspection Building Department Inspections are now scheduled online. If you have difficulties, please call the Building Department front desk for j assistance during office hours. (425) 771-0220 FIRE (425) 775-7720 PUBLIC WORKS (425) 771-0235 RECYCLING (425) 275-4801 When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection being requested, Contact Name and Phone Number, Date Preferred, and whether you prefer morning or afternoon. • F-Fire Sprinkler Bucket Test • F-Fire Sprinkler Pressure Test • F-F ire Sprinkler Acceptance • F-Fire Standpipe Inspection • F-Fire Final City of Edmonds DEVELOPMENT SERVICES RESIDENTIAL BUILDING PERMIT APPLICATION 121 5th Avenue N, Edmonds, WA 98020 Phone 425.771.0220 Q Fax 425.771.0221 PLEASE REFER TO THE RESIDENTIAL BUILDING CHECKLIST FOR SUBMITTAL REQUIREMENTS PROJECT ADDRESS (Street, Suite #, City State, Zip): $0 2100 ak � Parcel #: Subdivision/Lot #: Project Valuation: $ PLICANT- /� Phone: Zb - N8 Fax: 2°�- — 2 g� s Street, ity, State, Zip): lrd.,4yeQA(�Ml�b W,4s 2�® E-Mail Address: P OPERTY WNER: Phone: Fax: Address (Street, City, State, Zip): E-Mail Address: LENDING AGENCY: Phone: Fax: Address (Street, City, State, Zip): E-Mail Address: ONTRACTOR•* / / Phone: 00 Fax: Address (Street, City, State, Zip): E-Mail Address: *Contractor must have a valid City of Edmonds business license prior to doing work in the City. Contact the City Clerk's Office at 425.775.2525 WA State License #/Exp. ate: (p I a t Business License #/Exp. Date: 2 DETAIL THE SCOPE OF WORK: PROPOSED NEW SQUARE FOOTAGE FOR THIS PROJECT: Basement: s . ft. Select Basement Type: Finished LJ Unfinished Li 1st Floor: s . ft. Garage/Carport: -sq. ft. 2Id Floor: s . ft. Deck/Cvrd Porch/Patio: s . ft. Bedrooms # Full-3/4 Bath # Half -Bath # Other: sq. ft. Fire Sprinklers: Yes No 0 1 Retaining Wall: Yes No Li Grading: Cut cu. yds. Fill cu.yds. I Cut/Fill in Critical Area: Yes No LJ I declare under penalty of perjury laws that the information 1 have provided on this form/application is true, correct and complete, and that I am the property owner or duly authorized agent of the properly owner to submit a permit application to the City of Edmonds. ffi—aA Print Name: Owner ❑ Agent/Other (specify):�rn f n _ Signature: Date: aaij' v FORM A L: adding New Folder 20 0�DO & x-ferred to L-Building-New drive\Form A2014.docx Updated: 1/17/2014 O A,� DEVELOPMENT SERVICES _ RESIDENTIAL BUILDING PERMIT APPLICATION FORM A FSt. 1 aqo 121 5t° Avenue N, Edmonds, WA 98020 City of Edmonds Phone 425.771.0220 4 Fax 425.771.0221 Equipment Type Appliance/Equipment Information (new and relocated) 7ta7l# Furnace Gas #_Elec # Other: # BTUs: <100k_ >100k_ Location(s) Air Handler / VAV Gas #_Elec #_Other: # CFM: <10k_ >10k_ Location(s) (circle selected) AC / Compressor / Boiler / Heat Pump / Gas #_Elec #_Other: #_ BTUs: <100k, 100k-500k, 500k-1Mil Roof Top Unit HP: <3, 3-15, 15-30 Location(s) (circle selected) Hydronic Heating Gas #_Elec #_In -Floor _Wall Radiant_ Boiler BTUs: Location Exhaust Fans (single Bath #_Kitchen #_Laundry # # duct) _Other: Fireplace Gas #_Elec #_Other: #_ Location(s) Dryer Duct Appliance Type Appliance/Equipment Information (new and relocated) Total # AC Unit BTUs: Location(s): Furnace BTUs: Location(s): Water Heater BTUs: Location(s): Boiler BTUs: Location(s): Other: BTUs: Location(s): Fireplace/Insert BTUs: Location(s): Stove/Range/Oven Dryer Outdoor BBQ TOTAL OUTLETS PLUMBING FI►COUNT Fixture Type (new and relocated) Total # Fixture Type (new and relocated) Total # Water Closet (Toilet) Pressure Reduction Valve/Pressure Regulator Sink (Idtchen, laundry, lavatory, bar, eye wash, etc.) Water Service Line Tub/Shower Drinking Fountain Dishwasher Clothes Washer Hose Bib Backflow Prevention Device (e.g. RBPA, DCDA, AVB) Water Heater Tankless? Yes ❑ No ❑ Hydronic Heat in: Floor 0 WallEj Floor Drain/Floor Sink Other: Refrigerator water supply (for waterrice dispenser) Other: FORM A LABuilding New Folder 2010\DONE & x-ferred to L-Building-New drive\Fonn A2014.docx Updated: 1/17/2014 ALAQ017%- 1008o WMMMMr=Mrrrr•MrrrrrrWrrrrrrM WASHO940TON STATE CERTIFICATE OF COMPSTeNCY fiRR PROTlCTION SPRINKLER SYSTEMS Thomas Gill 7678-0409-A I"' , swn, M���1�rsrrrrrr..r.rrrrrrMrr rrr A00 DESIGN A-PEX Design Services, Inc.-EP 10731 47th Place West Mukilteo, WA 98275 425-493-9680 sales@a-pexdesignservices.com Job Name EDM5 LOT 1 PLAN 3110 - Two Head Calculation (H.17 & H.16) Drawing Location EDMONDS WA Remote Area Contract 170127-02 Data File 170127-02 EDM5 Lot 1 Plan 3110.wx2 - - -- ---- --- Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 DEC o5 20;7 DEVE CCTH ITY Of EDMONDS A-PEX Design Services, Inc.-EP Page 1 EDM5 LOT 1 PLAN 3110 - Two Head Calculation (H.17 & H.16) Date 1/27/2017 HYDRAULIC DESIGN INFORMATION SHEET Name - EDM5 LOT 1 PLAN 3110 Date - 1-27-2017 Location - EDMONDS WA Building - System No. - Contractor - ADVANCED PLUMBING Contract No. - 170127-02 Calculated By - KAREN.BABB Drawing No. - Construction: (X) Combustible ( ) Non -Combustible Ceiling Height OCCUPANCY - RESIDENTIAL S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )1 (X)2 ( )4 ( ) S ( ) Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7.04 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction _ E Domestic Flow Added - 0 Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make RELIABLE Model LL-RFC49 I Elevation at Highest Outlet - 116 Feet Size 3/8 K-Factor 4.9 G Note: Temperature Rating 155 N Calculation Gpm Required 26.0026 Psi Required 57.55 At Ref Pt STR Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 80 Elev. R Residual (Psi) - 75 Other Well Flow (Gpm) - 300 Proof Flow Gpm S Elevation - 100 P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 2 : alculation (H.17 & H.16) Date 1/27/2017 Demand: D1 - Elevation 6.930 D2 - System Flow : 26.003 D2 - System Pressure 57.551 Hose ( Demand ) D3 - System Demand : 26.003 Safety Margin 22.394 0 250 300 350 400 450 FLOW N^1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 calculation (H.17 & H.16) Page 3 Date 1 /27/2017 % 1 1 % 1 % 2 2% 3 3'/ 4 5 6 8 10 12 14 16 18 20 24 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 1 1 1 1 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 17 14 9 12 17 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 2 4 2 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 iches eet IS Gallons per Minute 'ounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - NFPA 2007 A-PEX Design Services, Inc.-EP Page 4 EDM5 LOT 1 PLAN 3110 - Two Head Calculation (H.17 & H.16) Date 1/27/2017 SUPPLYANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure STIR 80.0 75 300.0 79.946 26.0 57.551 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes H.16 116.0 4.9 7.04 13.0 H.24 116.0 8.82 T.43 116.0 11.21 T.44 116.0 11.54 T.40 108.0 17.4 S.1 104.0 20.29 PRV 100.0 38.04 CPL 100.0 41.16 MTR 100.0 52.24 STIR 100.0 57.55 T.37 116.0 7.04 H.17 116.0 4.9 7.04 13.0 T.38 116.0 10.12 H.21 116.0 10.26 H.25 116.0 10.94 T.45 116.0 11.3 T.42 108.0 15.57 H.13 108.0 15.65 H.14 108.0 15.72 H.18 108.0 15.99 H.23 108.0 16.13 T.41 108.0 16.14 T.39 108.0 17.11 T.36 116.0 10.19 HA 1 116.0 10.34 H.9 116.0 10.58 H.8 116.0 10.76 H.10 116.0 10.96 H.3 116.0 11.16 T.32 116.0 11.26 T.33 108.0 15.81 H.6 108.0 15.95 H.20 108.0 16.55 H.22 116.0 11.21 H.19 116.0 11.22 T.35 116.0 11.23 H.12 116.0 11.23 H.2 116.0 11.25 H.26 116.0 11.34 H.28 116.0 11.45 H.31 116.0 11.54 T.46 116.0 11.64 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - NFPA 2007 A-PEX Design Services, Inc.-EP Page 5 EDM5 LOT 1 PLAN 3110 - Two Head Calculation (H.17 & H.16) Date 1/27/2017 NODE ANALYSIS (cont.) Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes H.29 116.0 11.6 H.30 116.0 11.63 H.27 108.0 15.59 H.15 108.0 15.62 T.34 108.0 15.64 H.7 108.0 15.65 HA 108.0 15.68 H.5 108.0 15.71 H.1 108.0 15.77 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 'F,inal Calculations - Hazen -Williams A-PEX Design Services, Inc.-EP Page 6 EDM5 LOT 1 PLAN 3110 -Two Head Calculation (H.17 & H.16) Date 1/27/2017 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C', or Ftng's Pe Pv '' *"** Notes **"" Point Qt Pf/Ft Eqv. Ln. Total Pf Pn H.16 12.88 0.862 Utr 2.0 16.000 7.040 K Factor = 4.90 to 150.0 0.0 2.000 0.0 H.24 12.88 0.0992 0.0 18.000 1.785 Vel = 7.08 H.24 0.0 0.862 Utb 17.0 10.000 8.825 to 150.0 0.0 14.000 0.0 T.43 12.88 0.0992 0.0 24.000 2.381 Vel = 7.08 T.43 -1.08 0.862 Utr 2.0 2.000 11.206 to 150.0 0.0 2.000 0.0 T.44 11.8 0.0845 0.0 4.000 0.338 Vel = 6.49 T.44 -2.14 0.862 2Utb 34.0 13.000 11.544 to 150.0 0.0 28.000 3.465 T.40 9.66 0.0583 0.0 41.000 2.391 Vel = 5.31 T.40 16.34 1.054 T 2.44 6.000 17.400 to 150.0 0.0 2.440 1.732 SA 26.0 0.1367 0.0 8.440 1.154 Vel = 9.56 SA 0.0 1.054 2E 2.44 5.000 20.286 to 150.0 0.0 2.440 16.732 " * Fixed Loss = 15 PRV 26.0 0.1368 0.0 7.440 1.018 Vel = 9.56 PRV 0.0 1.054 2E 2.44 20.000 38.036 to 150.0 C 0.407 2.847 0.0 CPL 26.0 0.1367 0.0 22.847 3.124 Vel = 9.56 CPL 0.0 1.61 2E 12.089 50.000 41.160 to 150.0 0.0 12.089 10.000 * " Fixed Loss = 10 MTR 26.0 0.0174 0.0 62.089 1.079 Vel = 4.10 MTR 0.0 0.995 E 2.336 20.000 52.239 to 150.0 T 5.841 9.345 0.0 STIR 26.0 0.1810 G 1.168 29.345 5.312 Vel = 10.73 0.0 26.00 57.551 K Factor = 3.43 H.16 0.13 0.862 Utr 2.0 7.000 7.040 to 150.0 0.0 2.000 0.0 T.37 0.13 0.0 0.0 9.000 0.0 Vel = 0.07 T.37 0.0 0.862 Utr 2.0 3.000 7.040 to 150.0 0.0 2.000 0.0 H.17 0.13 0.0 0.0 5.000 0.0 Vel = 0.07 H.17 13.00 0.862 Utb 17.0 14.000 7.040 K Factor = 4.90 to 150.0 Utr 2.0 16.000 0.0 T.38 13.13 0.1028 0.0 30.000 3.085 Vel = 7.22 T.38 -4.72 0.862 Utr 2.0 1.000 10.125 to 150.0 0.0 2.000 0.0 H.21 8.41 0.0450 0.0 3.000 0.135 Vel = 4.62 H.21 0.0 0.862 Utr 2.0 13.000 10.260 to 150.0 0.0 2.000 0.0 H.25 8.41 0.0451 0.0 15.000 0.677 Vel = 4.62 H.25 0.0 0.862 Utr 2.0 6.000 10.937 to 150.0 0.0 2.000 0.0 T.45 8.41 0.0450 0.0 8.000 0.360 Vel = 4.62 T.45 -3.09 0.862 2Utb 34.0 14.000 11.297 to - -- - - t5fl-0- - - - -0.0 -28.000-- . -..---3.465------ - - - - -- - T.42 5.32 0.0193 0.0 42.000 0.811 Vel = 2.92 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 'Final Calculations - Hazen -Williams A-PEX Design Services, Inc.-EP Page 7 EDM5 LOT 1 PLAN 3110 -Two Head Calculation (H.17 & H.16) Date 1/27/2017 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv '**"** Notes ** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn T.42 -1.57 0.862 Utr 2.0 6.000 15.573 to 150.0 0.0 2.000 0.0 H.13 3.75 0.0101 0.0 8.000 0.081 Vel = 2.06 H.13 0.0 0.862 Utr 2.0 4.000 15.654 to 150.0 0.0 2.000 0.0 H.14 3.75 0.0102 0.0 6.000 0.061 Vel = 2.06 H.14 0.0 0.862 Utr 2.0 25.000 15.715 to 150.0 0.0 2.000 0.0 H.18 3.75 0.0101 0.0 27.000 0.274 Vel = 2.06 H.18 0.0 0.862 Utr 2.0 12.000 15.989 to 150.0 0.0 2.000 0.0 H.23 3.75 0.0101 0.0 14.000 0.142 Vel = 2.06 H.23 0.0 0.862 0.0 1.000 16.131 to 150.0 0.0 0.0 0.0 T.41 3.75 0.0100 0.0 1.000 0.010 Vel = 2.06 T.41 5.24 0.862 Utr 2.0 3.000 16.141 to 150.0 Utb 17.0 16.000 0.0 T.39 8.99 0.0510 0.0 19.000 0.969 Vel = 4.94 T.39 7.35 1.054 Utr 4.0 1.000 17.110 to 150.0 0.0 4.000 0.0 T.40 16.34 0.0580 0.0 5.000 0.290 Vel = 6.01 0.0 16.34 17.400 K Factor = 3.92 T.38 4.72 0.862 Utr 2.0 2.000 10.125 to 150.0 0.0 2.000 0.0 T.36 4.72 0.0155 0.0 4.000 0.062 Vel = 2.59 T.36 0.0 0.862 Utr 2.0 8.000 10.187 to 150.0 0.0 2.000 0.0 HA 1 4.72 0.0155 0.0 10.000 0.155 Vel = 2.59 HA 1 0.0 0.862 Utr 2.0 13.000 10.342 to 150.0 0.0 2.000 0.0 H.9 4.72 0.0155 0.0 15.000 0.233 Vel = 2.59 H.9 0.0 0.862 Utr 2.0 10.000 10.575 to 150.0 0.0 2.000 0.0 H.8 4.72 0.0155 0.0 12.000 0.186 Vel = 2.59 H.8 0.0 0.862 0.0 13.000 10.761 to 150.0 0.0 0.0 0.0 H.10 4.72 0.0155 0.0 13.000 0.201 Vel = 2.59 H.10 0.0 0.862 Utr 2.0 11.000 10.962 to 150.0 0.0 2.000 0.0 H.3 4.72 0.0155 0.0 13.000 0.202 Vel = 2.59 H.3 0.0 0.862 Utr 2.0 4.000 11.164 to 150.0 0.0 2.000 0.0 T.32 4.72 0.0155 0.0 6.000 0.093 Vel = 2.59 T.32 1.07 0.862 2Utb 34.0 20.000 11.257 to 150.0 0.0 28.000 3.465 T.33 5.79 0.0226 0.0 48.000 1.086 Vel = 3.18 T.33 1.56 0.862 Utr 2.0 2.000 15.808 to 150.0 0.0 2.000 0.0 H.6 7.35 0.0350 0.0 4.000 0.140 Vel = 4.04 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-PEX Design Services, Inc.-EP Page 8 EDMS LOT 1 PLAN 3110 - Two Head Calculation (H.17 & H.16) Date 1/27/2017 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv *"***" Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn H.6 0.0 0.862 Utr 2.0 15.000 15.948 to 150.0 0.0 2.000 0.0 H.20 7.35 0.0352 0.0 17.000 0.599 Vel = 4.04 H.20 0.0 0.862 Utb 17.0 2.000 16.547 to 150.0 0.0 14.000 0.0 T.39 7.35 0.0352 0.0 16.000 0.563 Vel = 4.04 0.0 7.35 17.110 K Factor = 1.78 T.43 1.07 0.862 Utr 2.0 2.000 11.206 to 150.0 0.0 2.000 0.0 H.22 1.07 0.0010 0.0 4.000 0.004 Vel = 0.59 H.22 0.0 0.862 Utr 2.0 7.000 11.210 to 150.0 0.0 2.000 0.0 H.19 1.07 0.0010 0.0 9.000 0.009 Vel = 0.59 H.19 0.0 0.862 Utr 2.0 8.000 11.219 to 150.0 0.0 2.000 0.0 T.35 1.07 0.0010 0.0 10.000 0.010 Vel = 0.59 T.35 0.0 0.862 Utr 2.0 1.000 11.229 to 150.0 0.0 2.000 0.0 H.12 1.07 0.0010 0.0 3.000 0.003 Vel = 0.59 H.12 0.0 0.862 Utr 2.0 14.000 11.232 to 150.0 0.0 2.000 0.0 H.2 1.07 0.0010 0.0 16.000 0.016 Vel = 0.59 H.2 0.0 0.862 Utr 2.0 7.000 11.248 to 150.0 0.0 2.000 0.0 T.32 1.07 0.0010 0.0 9.000 0.009 Vel = 0.59 0.0 1.07 11.257 K Factor = 0.32 T.45 3.09 0.862 Utr 2.0 4.000 11.297 to 150.0 0.0 2.000 0.0 H.26 3.09 0.0072 0.0 6.000 0.043 Vel = 1.70 H.26 0.0 0.862 Utr 2.0 13.000 11.340 to 150.0 0.0 2.000 0.0 H.28 3.09 0.0071 0.0 15.000 0.106 Vel = 1.70 H.28 0.0 0.862 Utr 2.0 11.000 11.446 to 150.0 0.0 2.000 0.0 H.31 3.09 0.0071 0.0 13.000 0.092 Vel = 1.70 H.31 0.0 0.862 0.0 15.000 11.538 to 150.0 0.0 0.0 0.0 T.46 3.09 0.0071 0.0 15.000 0.106 Vel = 1.70 T.46 2.14 0.862 2Utb 34.0 27.000 11.644 to 150.0 0.0 28.000 3.465 T.41 5.23 0.0188 0.0 55.000 1.032 Vel = 2.88 0.0 5.23 16.141 K Factor = 1.30 T.44 2.14 0.862 Utr 2.0 13.000 11.544 to 150.0 0.0 2.000 0.0 H.29 2.14 0.0036 0.0 15.000 0.054 Vel = 1.18 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-PEX Design Services, Inc.-EP Page 9 EDM5 LOT 1 PLAN 3110 - Two Head Calculation (H.17 & H.16) Date 1/27/2017 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv "'**** Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn H.29 0.0 0.862 Utr 2.0 7.000 11.598 to 150.0 0.0 2.000 0.0 H.30 2.14 0.0036 0.0 9.000 0.032 Vel = 1.18 H.30 0.0 0.862 Utr 2.0 2.000 11.630 to 150.0 0.0 2.000 0.0 T.46 2.14 0.0035 0.0 4.000 0.014 Vel = 1.18 0.0 2.14 11.644 K Factor = 0.63 T.42 1.56 0.862 0.0 8.000 15.573 to 150.0 0.0 0.0 0.0 H.27 1.56 0.0020 0.0 8.000 0.016 Vel = 0.86 H.27 0.0 0.862 Utr 2.0 15.000 15.589 to 150.0 0.0 2.000 0.0 H.15 1.56 0.0020 0.0 17.000 0.034 Vel = 0.86 H.15 0.0 0.862 Utr 2.0 4.000 15.623 to 150.0 0.0 2.000 0.0 T.34 1.56 0.0020 0.0 6.000 0.012 Vel = 0.86 T.34 0.0 0.862 Utr 2.0 7.000 15.635 to 150.0 0.0 2.000 0.0 H.7 1.56 0.0020 0.0 9.000 0.018 Vel = 0.86 H.7 0.0 0.862 Utr 2.0 12.000 15.653 to 150.0 0.0 2.000 0.0 H.4 1.56 0.0020 0.0 14.000 0.028 Vel = 0.86 H.4 0.0 0.862 Utr 2.0 13.000 15.681 to 150.0 0.0 2.000 0.0 H.5 1.56 0.0020 0.0 15.000 0.030 Vel = 0.86 H.5 0.0 0.862 Utr 2.0 29.000 15.711 to 150.0 0.0 2.000 0.0 HA 1.56 0.0020 0.0 31.000 0.063 Vel = 0.86 HA 0.0 0.862 Utr 2.0 15.000 15.774 to 150.0 0.0 2.000 0.0 T.33 1.56 0.0020 0.0 17.000 0.034 Vel = 0.86 0.0 1.56 15.808 K Factor = 0.39 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-PEX Design Services, Inc.-EP 10731 47th Place West Mukilteo, WA 98275 425-493-9680 sales@a-pexdesignservices.com Job Name EDM5 LOT 1 PLAN 3110 - One Head Calculation (H.7) Drawing Location EDMONDS WA Remote Area Contract 170127-02 Data File 170127-02 EDM5 Lot 1 Plan 3110.wx1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A-PEX Design Services, Inc.-EP EDM5 LOT 1 PLAN 3110 - One Head Calculation (H.7) HYDRAULIC DESIGN INFORMATION SHEET Name - EDM5 LOT 1 PLAN 3110 Location - EDMONDS WA Building - Contractor - ADVANCED PLUMBING Calculated By - KAREN BABB Construction: (X) Combustible OCCUPANCY - RESIDENTIAL Date - 1-27-2017 System No. - Contract No. - 170127-02 Drawing No. - ( ) Non -Combustible Ceiling Height S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: (X)1 ( )2 ( )4 ( ) S ( ) Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 17 Gpm System Type Listed Pres. at Start Point - 12.03Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 18 x 18 ( ) Deluge ( ) PreAction E Domestic Flow Added - 0 Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make RELIABLE Model LL-RFC49 I Elevation at Highest Outlet - 108 Feet Size 3/8 K-Factor 4.9 G Note: Temperature Rating 155 N Calculation Gpm Required 17 Psi Required 49.66 At Ref Pt STR Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: A Date of Test - T Time of Test - E Static (Psi) - 80 R Residual (Psi) - 75 Flow (Gpm) - 300 S Elevation - 100 P Location: P L Source of Information: Y Pump Data: Tank or Reservoir: Rated Cap. Cap. @ Psi Elev. Elev. Other Well Proof Flow Gpm Page 1 Date 1/27/2017 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I alculation (H.7) Page 2 Date 1 /27/2017 Demand: D1 - Elevation 3.465 D2 - System Flow : 16.995 D2 - System Pressure 49.657 Hose ( Demand ) D3 - System Demand : 16.995 Safety Margin 30.318 D 250 300 350 400 450 FLOW( N 1 1.85 ) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 ;alculation (H.7) Page Date 3 1/27/2017 % 1 1 % 1'/ 2 2% 3 T/z 4 5 6 8 10 12 14 16 18 20 24 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 1 1 1 1 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 17 14 9 12 17 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 2 4 2 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 fiches eet IS Gallons per Minute 'ounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 'low Summary - NFPA 2007 A-PEX Design Services, Inc.-EP EDM5 LOT 1 PLAN 3110 - One Head Calculation (H.7) Page 4 Date 1 /27/2017 SUPPLYANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure STIR 80.0 75 300.0 79.975 17.0 49.657 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes H.7 108.0 4.9 12.03 17.0 HA 108.0 12.54 H.5 108.0 13.1 H.1 108.0 14.23 T.33 108.0 14.86 T.32 116.0 11.51 H.2 116.0 11.54 H.12 116.0 11.59 T.35 116.0 11.6 H.19 116.0 11.63 H.22 116.0 11.66 T.43 116.0 11.68 T.44 116.0 11.71 T.40 108.0 15.87 S.1 104.0 18.13 PRV 100.0 35.32 CPL 100.0 36.75 MTR 100.0 47.24 STIR 100.0 49.66 T.34 108.0 12.54 H.15 108.0 12.87 H.27 108.0 13.83 T.42 108.0 14.28 T.45 116.0 11.42 H.26 116.0 11.45 H.28 116.0 11.53 H.31 116.0 11.6 T.46 116.0 11.67 T.41 108.0 15.22 T.39 108.0 15.71 H.13 108.0 14.41 H.14 108.0 14.51 H.18 108.0 14.96 H.23 108.0 15.2 H.6 108.0 14.95 H.20 108.0 15.34 H.25 116.0 11.44 H.21 116.0 11.49 T.38 116.0 11.5 H.17 116.0 11.56 T.37 116.0 11.57 H.16 116.0 11.59 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 'F,low Summary - NFPA 2007 A-PEX Design Services, Inc.-EP EDMS LOT 1 PLAN 3110 - One Head Calculation (H.7) Node Tag Elevation Node Type NODE ANALYSIS (cont.) Pressure Discharge at Node at Node H.24 116.0 11.62 T.36 116.0 11.5 H.11 116.0 11.5 H.9 116.0 11.5 H.8 116.0 11.5 H.10 116.0 11.5 H.3 116.0 11.51 H.30 116.0 11.68 H.29 116.0 11.69 Page 5 Date 1/27/2017 Notes Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fjnal Calculations - Hazen -Williams A-PEX Design Services, Inc.-EP Page 6 EDMS LOT 1 PLAN 3110 - One Head Calculation (H.7) Date 1/27/2017 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. , "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn H.7 7.53 0.862 Utr 2.0 12.000 12.030 K Factor = 4.90 to 150.0 0.0 2.000 0.0 H.4 7.53 0.0367 0.0 14.000 0.514 Vel = 4.14 H.4 0.0 0.862 Utr 2.0 13.000 12.544 to 150.0 0.0 2.000 0.0 H.5 7.53 0.0368 0.0 15.000 0.552 Vel = 4.14 H.5 0.0 0.862 Utr 2.0 29.000 13.096 to 150.0 0.0 2.000 0.0 H.1 7.53 0.0367 0.0 31.000 1.138 Vel = 4.14 H.1 0.0 0.862 Utr 2.0 15.000 14.234 to 150.0 0.0 2.000 0.0 T.33 7.53 0.0368 0.0 17.000 0.625 Vel = 4.14 T.33 -5.83 0.862 2Utb 34.0 20.000 14.859 to 150.0 0.0 28.000 -3.465 T.32 1.7 0.0023 0.0 48.000 0.112 Vel = 0.93 T.32 0.35 0.862 Utr 2.0 7.000 11.506 to 150.0 0.0 2.000 0.0 H.2 2.05 0.0033 0.0 9.000 0.030 Vel = 1.13 H.2 0.0 0.862 Utr 2.0 14.000 11.536 to 150.0 0.0 2.000 0.0 H.12 2.05 0.0033 0.0 16.000 0.053 Vel = 1.13 H.12 0.0 0.862 Utr 2.0 1.000 11.589 to 150.0 0.0 2.000 0.0 T.35 2.05 0.0033 0.0 3.000 0.010 Vel = 1.13 T.35 0.0 0.862 Utr 2.0 8.000 11.599 to 150.0 0.0 2.000 0.0 H.19 2.05 0.0033 0.0 10.000 0.033 Vel = 1.13 H.19 0.0 0.862 Utr 2.0 7.000 11.632 to 150.0 0.0 2.000 0.0 H.22 2.05 0.0033 0.0 9.000 0.030 Vel = 1.13 H.22 0.0 0.862 Utr 2.0 2.000 11.662 to 150.0 0.0 2.000 0.0 T.43 2.05 0.0032 0.0 4.000 0.013 Vel = 1.13 T.43 1.59 0.862 Utr 2.0 2.000 11.675 to 150.0 0.0 2.000 0.0 T.44 3.64 0.0095 0.0 4.000 0.038 Vel = 2.00 T.44 1.31 0.862 2Utb 34.0 13.000 11.713 to 150.0 0.0 28.000 3.465 T.40 4.95 0.0169 0.0 41.000 0.693 Vel = 2.72 T.40 12.05 1.054 T 2.44 6.000 15.871 to 150.0 0.0 2.440 1.732 S.1 17.0 0.0623 0.0 8.440 0.526 Vel = 6.25 S.1 0.0 1.054 2E 2.44 5.000 18.129 to 150.0 0.0 2.440 16.732 * * Fixed Loss = 15 PRV 17.0 0.0622 0.0 7.440 0.463 Vel = 6.25 PRV 0.0 1.054 2E 2.44 20.000 35.324 to 150.0 C 0.407 2.847 0.0 CPL 17.0 0.0623 0.0 22.847 1.423 Vel = 6.25 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams A-PEX Design Services, Inc.-EP Page 7 EDM5 LOT 1 PLAN 3110 - One Head Calculation (H.7) Date 1/27/2017 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv *"`" '*" Notes *** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn CPL 0.0 1.61 2E 12.089 50.000 36.747 to 150.0 0.0 12.089 10.000 * * Fixed Loss = 10 MTR 17.0 0.0079 1 0.0 62.089 0.491 Vel = 2.68 MTR 0.0 0.995 E 2.336 20.000 47.238 to 150.0 T 5.841 9.345 0.0 STIR 17.0 0.0824 G 1.168 29.345 2.419 Vel = 7.01 0.0 17.00 49.657 K Factor = 2.41 HY 9.47 0.862 Utr 2.0 7.000 12.030 to 150.0 0.0 2.000 0.0 T.34 9.47 0.0562 0.0 9.000 0.506 Vel = 5.21 T.34 0.0 0.862 Utr 2.0 4.000 12.536 to 150.0 0.0 2.000 0.0 H.15 9.47 0.0562 0.0 6.000 0.337 Vel = 5.21 H.15 0.0 0.862 Utr 2.0 15.000 12.873 to 150.0 0.0 2.000 0.0 H.27 9.47 0.0562 0.0 17.000 0.955 Vel = 5.21 H.27 0.0 0.862 0.0 8.000 13.828 to 150.0 0.0 0.0 0.0 T.42 9.47 0.0561 0.0 8.000 0.449 Vel = 5.21 T.42 -4.93 0.862 2Utb 34.0 14.000 14.277 to 150.0 0.0 28.000 -3.465 T.45 4.54 0.0145 0.0 42.000 0.608 Vel = 2.50 T.45 -1.93 0.862 Utr 2.0 4.000 11.420 to 150.0 0.0 2.000 0.0 H.26 2.61 0.0050 0.0 6.000 0.030 Vel = 1.43 H.26 0.0 0.862 Utr 2.0 13.000 11.450 to 150.0 0.0 2.000 0.0 H.28 2.61 0.0052 0.0 15.000 0.078 Vel = 1.43 H.28 0.0 0.862 Utr 2.0 11.000 11.528 to 150.0 0.0 2.000 0.0 H.31 2.61 0.0052 0.0 13.600 0.067 Vel = 1.43 H.31 0.0 0.862 0.0 15.000 11.595 to 150.0 0.0 0.0 0.0 T.46 2.61 0.0052 0.0 15.000 0.078 Vel = 1.43 T.46 -1.31 0.862 2Utb 34.0 27.000 11.673 to 150.0 0.0 28.000 3.465 T.41 1.3 0.0014 0.0 55.000 0.078 Vel = 0.71 T.41 4.92 0.862 Utr 2.0 3.000 15.216 to 150.0 Utb 17.0 16.000 0.0 T.39 6.22 0.0258 0.0 19.000 0.490 Vel = 3.42 T.39 5.83 1.054 Utr 4.0 1.000 15.706 to 150.0 0.0 4.000 0.0 T.40 12.05 0.0330 0.0 5.000 0.165 Vel = 4.43 0.0 12.05 15.871 K Factor = 3.02 T.42 4.92 0.862 Utr 2.0 6.000 14.277 to 150.0 0.0 2.000 0.0 H. 1-3- 4.92-0.01-68 -0.0 - ._-. 8.000 -- 0.134 - - Vel-2.70-- - -- - Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fjnal Calculations - Hazen -Williams A-PEX Design Services, Inc.-EP Page 8 EDM5 LOT 1 PLAN 3110 - One Head Calculation (H.7) Date 1/27/2017 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv * *'** Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn H.13 0.0 0.862 Utr 2.0 4.000 14.411 to 150.0 0.0 2.000 0.0 H.14 4.92 0.0168 0.0 6.000 0.101 Vel = 2.70 H.14 0.0 0.862 Utr 2.0 25.000 14.512 to 150.0 0.0 2.000 0.0 H.18 4.92 0.0167 0.0 27.000 0.452 Vel = 2.70 H.18 0.0 0.862 Utr 2.0 12.000 14.964 to 150.0 0.0 2.000 0.0 H.23 4.92 0.0168 0.0 14.000 0.235 Vel = 2.70 H.23 0.0 0.862 0.0 1.000 15.199 to 150.0 0.0 0.0 0.0 T.41 4.92 0.0170 0.0 1.000 0.017 Vel = 2.70 0.0 4.92 15.216 K Factor = 1.26 T.33 5.83 0.862 Utr 2.0 2.000 14.859 to 150.0 0.0 2.000 0.0 H.6 5.83 0.0230 0.0 4.000 0.092 Vel = 3.21 H.6 0.0 0.862 Utr 2.0 15.000 14.951 to 150.0 0.0 2.000 0.0 H.20 5.83 0.0229 0.0 17.000 0.389 Vel = 3.21 H.20 0.0 0.862 Utb 17.0 2.000 15.340 to 150.0 0.0 14.000 0.0 T.39 5.83 0.0229 0.0 16.000 0.366 Vel = 3.21 0.0 5.83 15.706 K Factor = 1.47 T.45 1.94 0.862 Utr 2.0 6.000 11.420 to 150.0 0.0 2.000 0.0 H.25 1.94 0.0029 0.0 8.000 0.023 Vel = 1.07 H.25 0.0 0.862 Utr 2.0 13.000 11.443 to 150.0 0.0 2.000 0.0 H.21 1.94 0.0030 0.0 15.000 0.045. Vel = 1.07 H.21 0.0 0.862 Utr 2.0 1.000 11.488 to 150.0 0.0 2.000 0.0 T.38 1.94 0.0030 0.0 3.000 0.009 Vel = 1.07 T.38 -0.35 0.862 Utb 17.0 14.000 11.497 to 150.0 Utr 2.0 16.000 0.0 H.17 1.59 0.0021 0.0 30.000 0.062 Vel = 0.87 H.17 0.0 0.862 Utr 2.0 3.000 11.559 to 150.0 0.0 2.000 0.0 T.37 1.59 0.0022 0.0 5.000 0.011 Vel = 0.87 T.37 0.0 0.862 Utr 2.0 7.000 11.570 to 150.0 0.0 2.000 0.0 H.16 1.59 0.0020 0.0 9.000 0.018 Vel = 0.87 H.16 0.0 0.862 Utr 2.0 16.000 11.588 to 150.0 0.0 2.000 0.0 H.24 1.59 0.0021 0.0 18.000 0.037 Vel = 0.87 H.24 0.0 0.862 Utb 17.0 10.000 11.625 to 150.0 0.0 14.000 0.0 T.43 1.59 0.0021 0.0 24.00 0050 Vel = 0.87 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fjnal Calculations - Hazen -Williams A-PEX Design Services, Inc.-EP Page 9 EDM5 LOT 1 PLAN 3110 - One Head Calculation (H.7) Date 1/27/2017 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ** "* Notes Point at Pf/Ft Eqv. Ln. Total Pf Pn 0.0 1.59 11.675 K Factor = 0.47 T.38 0.35 0.862 Utr 2.0 2.000 11.497 to 150.0 0.0 2.000 0.0 T.36 0.35 0.0002 0.0 4.000 0.001 Vel = 0.19 T.36 0.0 0.862 Utr 2.0 8.000 11.498 to 150.0 0.0 2.000 0.0 H.11 0.35 0.0001 0.0 10.000 0.001 Vel = 0.19 HA 1 0.0 0.862 Utr 2.0 13.000 11.499 to 150.0 0.0 2.000 0.0 H.9 0.35 0.0001 0.0 15.000 0.002 Vel = 0.19 H.9 0.0 0.862 Utr 2.0 10.000 11.501 -,to = 150.0 0.0 2.000 0.0 H.8 0.35 0.0001 0.0 12.000 0.001 Vel = 0.19 H.8 0.0 0.862 0.0 13.000 11.502 to 150.0 0.0 0.0 0.0 H.10 0.35 0.0002 0.0 13.000 0.002 Vel = 0.19 H.10 0.0 0.862 Utr 2.0 11.000 11.504 to 150.0 0.0 2.000 0.0 H.3 0.35 0.0002 0.0 13.000 0.002 Vel = 0.19 H.3 0.0 0.862 Utr 2.0 4.000 11.506 to 150.0 0.0 2.000 0.0 T.32 0.35 0.0 0.0 6.000 0.0 Vel = 0.19 0.0 0.35 11.506 K Factor = 0.10 T.46 1.31 0.862 Utr 2.0 2.000 11.673 to 150.0 0.0 2.000 0.0 H.30 1.31 0.0012 0.0 4.000 0.005 Vel = 0.72 H.30 0.0 0.862 Utr 2.0 7.000 11.678 to 150.0 0.0 2.000 0.0 H.29 1.31 0.0016 0.0 9.000 0.014 Vel = 0.72 H.29 0.0 0.862 Utr 2.0 13.000 11.692 to 150.0 0.0 2.000 0.0 T.44 1.31 0.0014 0.0 15.000 0.021 Vel = 0.72 0.0 1.31 11.713 K Factor = 0.38 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Reliable0 Bulletin 157 Rev.F Model F3QR Quick Response—— Dry Sprinklers DEC 05 OTT. Features 1. The Model F3QR sprinkler utilizes Belleville Spring Closure Technology. Reliable is the first in the industry to produce a Quick Response Dry Concealed sprinkler utilizing this technology. 2. Styles available • Pendent • Recessed Pendent CITV COPY • Concealed • Horizontal Sidewall • Recessed Horizontal Sidewall 3. 11/Y (38mm) escutcheon adjustment on pendent sprinkler. 4. 1/2' (13mm) escutcheon adjustment on recessed sprinkler with push -on/ thread -off FP Model Escutcheon ring. 5. /" (9.5mm) cover plate adjustment on concealed sprinkler with push -on/ thread -off CCP Cover Plate. 6. Attractive appearance. Employs 3mm frangible glass bulb and galvanized nipple. 7. Lengths available to accommodate installation dimensions from Z - to - 48" (51 mm - to-1219mm), in 1/4" (6mm) increments. 8. Available in avariety of plated and painted finishes. U.S. Patent Numbers 5,775,431 and 5,967,240. Approvals 1. Listed by Underwriters Laboratories Inc. and 11 A fnr ( nnor4n /rl II 1 ICl v Style Response Spnnider rn Type Hazard Pendent Recessed Pendent CCP Concealed Wet Pipe Light R5714 Quick Dry Pipe All leaction Ordinary Horizontal Sidewall Recessed Horizontal Sidewall R5734 9 C:artifiPH by FM Annrovals Style Response Sprnlder System T Hazard Pendent Quick Wet Pipe, Singleaction� Light Ordinary. Groups (R5714)PPrr 1&2 Horizontal Sidewall Wet Pipe, (R5734) Quick Singgle Interlock Light al ction city Cr Concealed Recessed Pendent Pendent Horizontal Sidewall 3. NYC MEA 258-93-E The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Model F3QR Dry Pendent Concealed Sprinkler "A" Dim. 1 31 " to 48"(89mm to 1219mm) in W' (6mm) increments CCP Cover Plate''' Finishes(Z) Standard Finishes Special Application Finishes Chrome Plated Bright Brass Plated White Black Plated Black Paint Off White Satin Chrome "' Utilizes they" cover plate with %" total adjustment. `2) Other finishes and colors are available on special order. Consult factory for details. Standard Temperature Ratinas Sprinkler Temperature Cover Plate Max. Classification Rating Temp. Rafin Ambient Tem . Ordinary 135°F (57°C) 135°F (57°C) 100°F (38°C) Ordinary 155°F (68°C) 135°F (57°C) 100°F (38°C) Intermediate 200°F (93°C) 165°F (74°C) 150°F (66°C) High* 286°F 141°C) 165°F 74°C 150°F 66°C) " Listed and Certified only by cULus. Sprinkler Installation Wrench: Model G3 R/C Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 Inlet Protrusion Elevated Above Inside Pipe }} 1�11 —3t- � 1 ru , System Tee 1" NPT 2 1/2" Dia. [6.35mmI "A" Dimension Hole in Ceiling Adjustment Range ± 3/16" 2 19/64" Dia. 1±4.76mm] [58.34mm] Nominal Position Sprinkler of Coverplate Cup Assembly _ Coverplate j Ceiling , L Assembly Ceilings 3/16" [4.76mm] Coverplate Adjustment Note: Do not install the Model F3QR Dry Pendent Concealed Sprinkler in ceilings which have positive pressure in the space above. Model F3QR Dry Horizontal Sidewall Sprinkler r`A" Dim. 1 2'to48'(51Trim to 1219mm) in'W 6mm increments Finishesf'f Sprinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated White Painted''' White Other finishes and colors are available on special order. Consult factory for details. t" White painted sprinklers will have chrome plated can. Standard Temperature Ratinas Sprinider Temperature Max Bulb Classification Rating Ambient Tem . Color Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate 200°F (93°C) 150°F (66°C) Green High 1286OF 141°C 225°F 107°C Blue 1 Total Adjustment Total Adjustment ' i r Ceiling i 4" [101.60mm] Min. 1 1 /4" [31.75mm] 12" [304.80mm] Max Escutcheon Adjustment 1 1/4" [6.35mm] System Tee f Escutcheon Adjustment 1" NPT IhI I1,11, 2 3/32153.18mmeilee 3" 1 _—___—_ — _—___ --_— — [76.20mm] LI/"D" n Wall/4" [6.35mm] rinkler Can Protrusion Dimension Adjustment Nominal Position ] +6.35mm4 / + Range 1 " [ of Escutcheon rsJrcoe-c 9 Sprinkler Installation Wrench: Note: The sprinkler Can protrudes'/411 when escutcheon is Model G3 Sprinkler Wrench in nominal position. Escutcheon adjustment pro- vides +/4 (+6mm) to -1 /4' (-32mm) "A" dimension Sprinkler Identification Number (SIN): R5734 adjustment range. 3. Model F3QR Dry Horizontal Recessed Sidewall Sprinkler " A" Dim. I 3'/2'to 4a' 89mm to 1219mm in'/a' 6mm increments Finishes''' Sprinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated White Painted White "Other finishes and colors are available on special order. Consult factory for details. Cup remains unfinished. "See page 2" Standard Temperature Ratings Sprinlder Temperature Max Bulb Classification Rating Ambient Tem . Color Ordinary 135OF (57°C) 100°F (38°C) Orange Ordinary 155OF (68°C) 100°F (38°C) Red Intermediate 200OF (93°C) 150OF (66°C) Green High* 286°F (141°C) 225OF (107°C) Blue * Listed and Certified only by cULus. Sprinkler Installation Wrench: Model G3 R/C Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 Technical Data: Orifice Size:'/z' (15mm) Thread Size: 1" NPT per ANSI 132.1 Working Pressure: 175 psi (12 bar) Nominal K Factor - US / (Metric): 5.6 / (80) Product Description Reliable Model F30R Dry Sprinklers are quick response sprinklers utilizing a durable 3mm frangible glass bulb. This quick response enables these sprinklers to apply water to a fire much sooner than standard response sprinklers of the similar temperature rating. Model F30R Dry Sprinklers are intended for use in enclosed dry and preaction systems and in enclosed areas subjected to freezing temperatures, such as freezers and unheated portions inside buildings. Environments wherein dry sprinklers are employed can be corrosive. For this reason, Model F3 Sprinklers have a special wax fillet placed in the gap between the cup that supports the bulb and the wrenching boss. This wax will not Interfere with the operation of the sprinkler, and it prevents contaminents from entering the internal portion of the drop nipple. The wax must not be removed. Operation The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. When the temperature increases sufficiently, due to a fire, the bulb shatters allowing operating parts to clear the waterway. This ----enables the inlet seal to release air or water and subsequently, cause water flow over the deflector in a uniform spray pattern, controlling or extinguishing the fire. M 1 13/32" Escutcheon [35.7mm] T 4' [101.6mm]Min. — System Tee Cu:X'I I12" (304,Bmm]Ma> * NPT 3 7/32" Dia. 2 1/2' [63.5mm] i Hole in Walt 3 2 19/64" Did. [-_J [58.3mm] 1/2" [12.7mm] "A" Dimension LEscutcheon Adjustment Adjustment Range 157FG05 +1/2 —0 [+12.7mm —0] • FOR FACTORY MUTUAL (FM) • 4" — 6' FOR UNDERWRITERS LABORATORIES (UL) Notes: Do not install the Model F3QR Dry Horizontal Recessed Sidewall Sprinkler in walls which have positive pressure in their side space. Listed by cULus for Quick Response. Approved by FM for Standard Response. Recessed Horizontal sidewall sprinklers are listed with cULus for installation of min. 4" (100mm) - to - max. 6" (150mm) below ceiling and approved by FM for installation of min. 4" (100mm) - to - max. 12" (300mm) below ceiling. Ordering Information Specify: 1. Sprinkler Type (select one): (a) Model F3QR Dry Pendent (b) Model F3QR Dry Recessed Pendent (c) Model F3QR Dry Concealed Pendent (d) Model F30R Dry Horizontal Sidewall (e) Model F3QR Dry Recessed Horizontal Sidewall 2. Sprinkler Temperature Rating. 3. Sprinkler Finish. 4. Cover Plate/Escutcheon Finish. 5. Length: "A" Dimension (face of tee to face of ceiling or wall) in (6mm) increments. 6. Model F3QR Dry Pendent (a) is available without sprinkler can and escutcheon. Note: 1. The "A" dimension is based on a nominally gauged pipe thread "make-up" of 0.600" (15mm) per ANSI 132.1 [71/2threads approximately]. 2. All platings and paintings are decorative and intended for interior use. General Installation Instructions Model F3QR dry sprinklers must be installed only in standard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) pipe tees even at branch line ends. They should not be installed into elbows and pipe couplings located on drop nipples to the sprinklers. For these and other fittings including CPVC*, the dry sprinkler should be installed into a fitting to conform to protrusion into the fitting in ac- cordance with the diagrams. The "A" dimension of the dry sprinkler, which extends into the freezers or a freezing zone from wet pipe systems, should be selected to pro- vide, as a minimum, the specified lengths in inches shown in the following chart, between face of the fitting and the outside wall or ceiling of the protected area. The following chart is used for freezing zones when the ambi- ent temperature around the wet pipe system is kept at 40 °F/ 4°C), and specifies the minimum length for fitting face to ceiling or wall (outside) for different protected area temperatures. Length Face to Ceilin Mall Temperature Protected Area)** 12 inches / 300 mm -200F / -29°C 18 inches / 450 mm -40°F / -40°C 24 inches / 600 mm -60°F / -51 °C ** For temperatures falling between those in the above chart, the minimum length may be determined by interpolation. During installation, the following steps must be followed 1. Cut the specified size hole (see illustrations) for the sprinkler in the ceiling or wall directly in line with the tee. 2. Apply pipe joint compound to the 1" (25mm) pipe threads and install sprinkler using the Model G3 or G3 R/C Sprinkler Wrench as specified. 3. Install the Model FP push -on / thread -off escutcheon or CCP cover plate if required. Note: Installation of the Model F3QR Sprinklers is not rec- ommended in copper pipe systems, as this may reduce the life expectancy of the sprinklers. Model F3QR Concealed and Recessed Installation Instructions The Model G3 R/C wrench (Fig. 1) is designed to locate on the wrenching pads of the recessed sprinkler while centering in the cup. A standard'/2" drive ratchet may be used to drive this wrench. Figures 1 and 2 show sequentially the insertion of the wrench. First the wrench, with its jaws above the sprinkler deflector, is moved laterally until centered with the cup. Then raise the wrench inside of the cup until its jaws engage the sprinkler's square wrenching pads (Fig. 3). To remove the wrench, follow this procedure in reverse order. Care should be taken to avoid striking the deflector, with the wrench. Model G3 Wrench (Fig. 4) is used for installation of Pendent and Horizontal Sidewall sprinklers. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Maintenance The Model F3QR Quick Response Dry Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not remove the factory applied thermally sensitive wax fillet between the bulb supporting cup and the wrenching boss. Do not replace this wax with a substitute substance. An Alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gently vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. * Spears CPVC sprinkler adapter tees (with steel thread insert) can only be used with horizontal sidewall sprinklers which do not require protrusion into tees to prevent ice or debris blockage of sprinkler inlets. These CPVC tees do not permit sufficient sprinkler inlet protrusion as required for pendent installation. 5. Reliable Specifically Listed for use in Multipurpose Systems that serve both domestic water and fire protection. Sprinkler Type Residential Flat Concealed Sprinkler listed for a minimum design density of .05 gpm/ft2 with "potable water". • Model RFC30 LL • Model RFC43 LL • Model RFC49 LL Features 1. National Sanitation Foundation (NSF) Cer- tified to NSF/ANSI Standard 61 Annex G (Less than 0.25% Lead content). 2. Very low water flow requirements. 3. Cover plate attachment (Plain or Perforated) with 1/2" (13mm) total adjustment 4. Thread-on/off or Push-on/off cover attach- ment option. 5. Smooth Aesthetic ceiling profile. 6. Available in white, brass, chrome and black plated or custom painted finishes. Patent Pending Listing & Approvals 1. Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) 2. NSF Cerified to NSF/ANSI Standard 61 Annex G Product Description Model RFC30 LL, RFC43 LL and RFC49 LL Concealed Residential Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers dif- fer from standard sprinklers primarily in their response time and water distribution patterns. Model RFC30 LL, RFC43 LL and RFC49 LL sprinklers discharge water in a hemi- spherical pattern below the sprinkler deflector. Residen- tial distribution- patterns are higher and generally contain Bulletin 032 Rev. C Model RFC30 LL (SIN RA3211) Model RFC43 LL (SIN RA3212) Model RFC49 LL (SIN RA3216) Residential Flat Concealed Sprinklers Plain Cover Plate -------------------- Perforated Cover Plate a finer droplet size than standard sprinkler patterns. The combination of speed of operation and high discharge pat- tern required for residential sprinklers has demonstrated, in fire testing, an ability for controlling residential fires, and thereby providing significant evacuation time for occu- pants. The RFC30 LL, RFC43 LL and RFC49 LL Sprinklers provide the best form of fire protection by combining an at- tractive appearance and'h" (13mm) of cover adjustment for ease of installation. The small diameter cover plate is easily and positively attached and blends into the ceiling, concealing the most dependable fire protection available, an automatic sprinkler system. The RFC30 LL, RFC43 LL and RFC49 LL are UL Listed and NSF Certified Residen- tial Sprinklers to be installed in the residential "potable" water applications of any occupancy in accordance with NFPA 13, 13R, & 13D and meets all applicable low lead standards, .25% or less. The cover plate adjustability of the RFC30 LL, RFC43 LL and RFC49 LL can reduce the need for precise cutting of drop nipples. The threaded cover plate assembly can be adjusted without tools to fit accurately against the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate assembly. W CD 0 W CD C z Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application and Installation For use in fire sprinkler systems that also supply potable water to a plumbing fixture or fixtures. The RFC30 H , RFC43 LL and RFC49 LL, for residential installer lions, use a 165°F (74°C) fusible solder link in a tuning fork style sprin- kler frame with a drop -dawn deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate. The cover plate is attached to the skirt, using 135°F (57°C) ordinary temperature clas- sification solder, When the ceiling temperature rises, the solder hold- ing the cover plate releases the cover allowing the deflector to drop into position and exposing the sprinkler inside to ceiling temperature. The subsequent operation of the solder link opens the waterway and causes the deflector to drop into position to distribute the discharging water in a hemispherical pattern below the sprinkler deflector. Any adjustment of thread engagement between the cover plate and cup will assure that the drop -doom deflector is properly located below the ceiling. The residential distribution pattern contains a finer droplet size than a standard sprinkler, and the pattern produces significantly higher wall wetting. After a21/$' inch diameter hole is cut in the ceiling, the sprinkler is to be installed with the Model FC Wrench. Installation Data: When installing a sprinkler, the wrench is first positioned into the sprinkler/cup assembly and around the hexagonal body of the sprin kler frame. The wrench must bottom out against the cup in order to ensure proper, safe installation. The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler DO NOT WRENCH ON ANY OTHER PARTOF THE SPRINKLER /CUP ASSEMBLY. MODEL RFC-30 LL, RFC43 LL AND RFC49 LL CONCEALED SPRINKLERS MUST BE INSTALLED ONLY WITH 135°F RATED COVERS. Note: A leak tight 112' NPT (R1/2) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maxmum recommended torque. It may cause leakage or irr pairment of the sprinklers. Cover assemblies provide up to'/2" (13mm) of adjustment. Turn the cover clockwise until the flange is in contact with the ceiling. For the push-on/ihread-off option, the cover assembly is pushed onto the cup and final adjustment is made by turning the cover clockwise un- til the skirt flange makes full contact with the ceiling. Cover removal Model (SIN) Thread Size Inch (mm) Nominal Orifice Inch (mm) Sprinkler Temp ating CCP Assembly Temp. Ratin Max. Ambient Tem • K Factor Max. Pressure psi (bar) OF °C OF °C OF °C RFC 30 LL (RA3211) 1/2" 15 21/64 (8,2) 165 74 135 57 100 38 3.0 (43.2) 175 (12) RFC 43 LL (RA3212) 1/2" (15) 3/a (10) 165 74 135 57 100 38 4.3 (62 175 (12) RFC 49 LL (RA3216) 112" (15) '/s (11) 165 74 135 57 100 38 1 4.9 (70.6) 1 175 (12) Note: 1 bar = 100 Kpa RFC 30 LL Max. Coverage Ordinary Temp. Rating Top of reflector Minimum area Max. Spacing 1650Fl740C to Ceiling Installation Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Type Ft (m) GPM (Umin) PSI bar 12 x 12 (3,6 x 3,6) 12(3,6) 9(34,1) 9.0 (0,62) Smooth Ceilings 1/2 to 1(13 to 25.4) .Beamed Ceilings per NFPA 13D, 13R or Concealed 8(2,4) 14 x 14 (4,3 x 4,3) 14(4,3) 10 (37,8) 11.0 (0,76) 13 installed in beams 1/2 to 1(13 to 25.4) For Ceiling types refer to NFPA 13, 13R or 13D RFC 43 LL Max. Coverage Max. Spacing Ordinary Temp. Rating 165°F/74°C Top of Deflector Installation Minimum area Ft (m) to Ceiling Type Spacing Flow Pressure Ft x Ft (m x m) GPM Umin PSI(bar)Inch (mm) Ft (m) 12 x 12 3,6 x 3,6 12(3,6) 12(4,5) 7.8 (0,54 Smooth Ceilings 1/2 to 1(13 to 25.4) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 1/2 to 1 (13 to 25.4) Concealed 8(2,4) 14 x 14 (4,3 x 4,3) 14(4.3) 13 (49) 9.1 (0,63) 16 x 16 (4,9 x 4,9) 16(4.9) 13 (49) 9.1 (0,63) 18 x 18 (5,5 x 5,5) 18(5,5) 18 (68) 17.5 (1,21) 20 x 20 (6,1 x 6, 1) 20(6,1) 21(79) 23.8(1,64) For Ceiling types refer to NFPA 13, 13R or 13D RFC 49 LL Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating 1650F/740C Top of Deflector to Ceiling Inch (mm) Installation Type Minimum Spacing Ft (m) Flow GPM (Umin) Pressure PSI bar 12 x 12 (3,6 x 3,6) 12(3,6) 13 (49) 7.0 (0,48) Smooth Ceilings 1/2 to 1(13 to 25.4) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 1/2 to 1 (13 to 25.4) Concealed 8(2,4) 14 x 14 (4,3 x 4,3) 14(4,3) 13 (49) 7.0 (0,48) 16 x 16 (4,9 x 4,9) 16(4.9) 13 (49) 7.0 (0,48) 18 x 18 5,5 x 5,5 18(5,5) 17 64,3 12.0 0,83 20 x 20 (6,1 x 6, 1) 20(611)' 20(75,73) 16.7(1,14) For Ceiling types refer to NFPA 13, 13R or 13D 2. requires turning in the counter -clockwise direction. In ceilings that have a plenum space above the sprinkler, the plenum space may have neutral or negative pressurization but must not be positively pressurized. Inspect all sprinklers after installation to ensure that the gap between the cover plate and ceiling and the 4 slots in the cup are all open and free from any air flow impedf menL Maintenance Model RFC30 LL, RFC43 LL and RFC49 LL Concealed Sprinklers should be inspected quarterly and the sprin- kler system maintained in accordance with NFPA25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler cover plate as- sembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. Model RFC30 LL, RFC43 LL and RFC49 LL Residential Concealed Sprinkler Specification Sprinklers shall be cULus Listed and NSF-61 Annex G certified low flow residential concealed sprinklers with drop - down deflector and adjustable flat cover plate engineered for a minimum design density of 0.05gpm/ft2. Sprinkler frame and deflector shall be of bronze frame construction having a 112" NPT thread. Thermal element shall consist of an approved black - painted beryllium -nickel fusible solder link with symmetric lever mechanism, maintaining a Teflon -coated Belleville spring washer and machined brass cap water seal assem- bly containing no plastic parts. Sprinkler K-factors shall be a nominal 3.0 (43.2), 4.3 (62) and 4.9 (70.6), having a 3/8" Specify: 1. Sprinkler Model 2. Cover Plate Finish 3. Thread -On or Push -On Feature I" x 112" REDUCING TEE OR ELBOW 1 III _ III (-1 2J- [66.55mmJ [58.42mm] DIA HOLE IN CEILING CUP _J MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION CEILING iixxxxx [12.70mm] MAX. I COVER ADJUSTMENT 76 [4.96mmJ CCP COVER PLATE 3J" [84.21mm] DIA. ASSEMBLY SPRINKLER 006FCOIA - -COVER- PLATE: 112 " L 12. 7mm I ADJUSTMENT and 7/16" orifice respectively. Temperature rating shall be Ordinary 165OF (740C); cover plate temperature rating to be 135°F (57°C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange allow- ing a'h" cover plate adjustment. Any secure engagement between the cover plate and the cup will assure that the drop -down deflector is properly located below the ceiling. A plastic protective cap shall be provided and factory in- stalled inside the sprinkler cup to protect the drop -down sprinkler deflector from damage, which could occur during construction before the cover plate is installed. Standard cover finish: [Chrome] [White] [Specialty — specify]. Resi- dential concealed sprinklers shall be Reliable Model RFC30 LL, SIN RA3211 (Bulletin 032), RFC43 LL, SIN RA3212 (Bul- letin 032) or Model RFC49 LL, SIN RA3216 (Bulletin 032). Ordering Information Cover Plate Finishes') Standard Finishes Chrome White Paint Special Application Finishes(2) Bright Brass Finished Bronze Black Plating Black Paint Off White Satin Chrome (11 Other finishes and colors are available on special order. Consult factory for details. Coverplate custom paint is semi -gloss, unless specified otherwise. (2) For the perforated style cover - plate, consult factory for avail- ability on these and other cus- tom finishes. 3. uponof Uponor AquaPEX° White Submittal Information Revision C: Oct. 7, 2009 Project Information Job Name: Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data Material: Crosslinked polyethylene PEX-a Engel Method; PEX 5006 Standard Grade Hydrostatic 200OF (93°C) at 80 psi Ratings (PPI): 180OF (82°C) at 100 psi 73.4°F (23°C) at 160 psi 1/2", 3/4", and 1" AquaPEX® White only: 120OF (49°C) at 130 psi Linear Expansion Rate: 1.10"/10°F (12°C)/100' Product Information and Application Use Uponor AquaPEX White is tubing used for hot and cold domestic potable water distribution, residential fire safety and radiant heating systems containing no ferrous corrodible components or where ferrous components are isolated from the tubing. ✓ Description Part Number I.D. (A) O.D. (B) Weight _ 1/4" Uponor AquaPEX White, 100-ft. coil F1040250 0.241" 0.375" 4.0 lbs. _ 3/s" Uponor AquaPEX White, 400-ft. coil F1090375 0.350" 0.500" 20.0 lbs. 3/8" Uponor AquaPEX White, 1,000-ft. coil F1120375 0.350" 0.500" 44.0 lbs. 1/2" Uponor AquaPEX White, 100-ft. coil* F1040500 0.475" 0.625" 6.0 lbs. 1/2" Uponor AquaPEX White, 300-ft. coil* F1060500 0.475" 0.625" 18.0 lbs. 1/2" Uponor AquaPEX White, 1,000-ft. coil* F1120500 0.475" 0.625" 54.0 lbs. 5/8" Uponor AquaPEX White, 300-ft. coil F1060625 0.574" 0.750" 28.0 lbs. _ S/a" Uponor AquaPEX White, 1000-ft. coil F1120625 0.574" 0.750" 86.0 lbs. 3/4" Uponor AquaPEX White, 100-ft. coil* F1040750 0.671" 0.875" 10.0 lbs- 3/4" Uponor AquaPEX White, 300-ft. coil* F1060750 0.671" 0.875" 34.0 lbs. 3/4" Uponor AquaPEX White, 500-ft. coil* F1100750 0.671" 0.875" 54.0 lbs. 1" Uponor AquaPEX White, 100-ft. coil* F1041000 0.862" 1.125" 20.0 lbs. 1" Uponor AquaPEX White, 300-ft. coil* F1061000 0.862" 1.125" 56.0 lbs. 1" Uponor AquaPEX White, 500-ft. coil* F1101000 0.862" 1.125" 93.0 lbs. 11/4" Uponor AquaPEX White, 100-ft. coil F1061250 1.054" 1.375" 34.0 lbs. 11/4" Uponor AquaPEX White, 300-ft. coil F1021250 1.054" 1.375" 106.0 lbs. 11/2" Uponor AquaPEX White, 100-ft. coil F1061500 1.244" 1.625" 44.0 lbs. 11/2" Uponor AquaPEX White, 300-ft. coil F1021500 1.244" 1.625" 133.0 lbs. 2" Uponor AquaPEX White, 100-ft. coil F1062000 1.629" 2.125" 68.2 lbs. 2" Uponor AquaPEX White, 200-ft. coil F1052000 1.629" 2.125" 136.4 lbs. 2" Uponor AquaPEX White, 300-ft. coil F1022000 1.629" 2.125" 204.6 lbs. 3" Uponor AquaPEX White, 100-ft. coil F1063000 2.400" 3.125" 128.0 lbs. 3" Uponor AquaPEX White, 350-ft. coil F1023000 2.400" 3.125" 442.0 lbs. Installation Approved fittings are ProPEXO fittings' for sizes 3/a" through 2" AquaPEX. Use WIPEXTm fittings for 3" AquaPEX. Refer to the AquaPEX Professional Plumbing Installation Handbook, AquaSAFETM Fire Safety Installation Guide or the Uponor Radiant Installation Handbook for details. Standards Codes CSA B137.5; ASTM F876; ASTM IPC; UPC; F877; ASTM F1960; ASTM-E84; NSPC; NPC ASTM-E119/UL 263 of Canada Related Applications PEX-a Plumbing Systems AquaSAFE Fire Safety Systems Listings *1/2", 3/4", 1" UL 1821; *ULC/ORD - C 199 P; IAPMO; CSA; HUD; WARNOCK HERSEY; NSF; ITS; UL; ICC; ANSI/NSF 14- and 61-certified; CAN/ULC S102.2; U.S.: 3/4" diameter and smaller; Canada: 1" diameter and smaller Contact Information Uponor, Inc. 5925 148th Street West Apple Valley, MN 55124 USA Phone: (800) 321-4739 Fax: (952) 891-2008 www.uponor-usa.com Uponor Ltd. 2000 Argentia Rd., Plaza 1, Ste. 200 Mississauga, ON L5N 1W1 CANADA Phone: (888) 994-7726 Fax: (800) 638-9517 www.uponor.ca 1ProPEX® is a registered trademark of Uponor, Inc. ProPEX`" is a trademark of Uponor Ltd. ProPEX° Ring Submittal Information Revision A: March 17, 2009 Project Information Job Name: Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data Material: PEX-a (Engel Method) Density: 926 to 940 kg/m3 Degree of Crosslinking: 70% to 89% Product Information and Application Use Manufactured from PEX-a material, Uponor ProPEX° Rings are required to make a proper ProPEX connection.' Red print on the rings indicates hot lines. The 1/2" and 3/4" ProPEX rings with stop includes a leading edge chamfer and stop edge. ✓ Description ProPEX Ring, 3/s" ProPEX Ring with Stop, 1/2" (red print) ProPEX Ring with Stop, 1/2" ProPEX Ring, 5/s" ProPEX Ring with Stop, 3/4" ProPEX Ring, 1" ProPEX Ring, 1'/4" ProPEX Ring, 11/2" ProPEX Ring, 2" Installation uponof Part Number Length i.d. o.d. Weight Q4690302 0.54" 0.49" 0.74" 0.005lbs. Q4690511 0.63" 0.63" 0.87" 0.006lbs. Q4690512 0.63" 0.63" 0.87" 0.006lbs. Q4680625 0.79" 0.75" 1.00" 0.008lbs. Q4690756 0.87" 0.88" 1.13" 0.012lbs. Q4681000 1.10" 1.13" 1.42" 0.020lbs. Q4681250 1.35" 1.38" 1.66" 0.030lbs. Q4681500 1.61" 1.63" 1.91" 0.040lbs. Q4682000 1.97" 2.14" 2.61" 0.133lbs. Square cut the Uponor ProPEX tubing. Remove excess material. Slide the ProPEX Ring over the end of the tubing (maximum'/,e over -hang). When using the 1/2" ProPEX Ring with stop edge, slide the ring on (i.e., chamfered edge first) until the end of the tubing contacts the stop edge. Expand tubing and ring. Rotate tool a quarter turn after each expansion to prevent the formation of grooves. Remove the expansion tool and fully seat the tubing and ring against the shoulder of the fitting. You should make ProPEX connections at temperatures above 50F /-15°C. For more information, refer to the AquaPEX® Professional Plumbing Installation Handbook, AQUASAFE® Fire Safety Installation Guide or the Uponor Radiant Installation Handbook. Standards ASTM F1960 Codes IPC; UPC; NSPC; NPC of Canada Listings UL 1821 (1/2", 3/4" and 1"); ULC/ORD - C 199 P (1/2", 3/4" and 1"); HUD MR 1269; ICC ESR 1099; ANSI/NSF 14- and 61-certified Related Applications Contact Information PEX-a Plumbing Systems Uponor, Inc. Uponor Ltd. Radiant Heating and Cooling Systems 5925 148t' Street West 2000 Argentia Rd., Plaza 1, Ste. 200 AQUASAFE Fire Safety Systems Apple Valley, MN 55124 USA Mississauga, ON L5N 1W1 CANADA Phone:(800) 321-4739 Phone: (888) 994-7726 Fax: (952) 891-2008 Fax: (800) 638-9517 www.uponor-usa.com www.uponor.ca 'ProPEX® is a registered trademark of Uponor; Inc. ProPEX'" is a trademark of Uponor Ltd. ProPEX° Engineered Submittal Information Revision D: June 8, 2012 Project Information Polymer (EP) Tee Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data Material: UDEL® Polysulfone, 20% Glass -reinforced (1/2" to 1") Acudel° Modified Polyphenylsulfone (11/4" to 11/2") Radel® Polyphenylsulfone (2") Maximum Temperature (no pressure): 320°F(160°C) Maximum Working Temperature/Pressure: 210OF (99°C) at 150 psi (1,034 kPa) Product Information and Application Use The ProPEX® Engineered Polymer (EP) Tee makes diverting connections for Uponor crosslinked polyethylene (PEX-a) tubing for use in hot and cold domestic potable water systems, residential fire sprinkler systems and hydronic radiant heating and cooling systems. Each end of the tee is manufactured with an Uponor ProPEX fitting for connections to Uponor AquaPEX® or Wirsbo hePEXTM tubing.' Note: Branch size is listed last in the part descriptions. uponof Description Part Number A B Weight ❑ ProPEX EP Tee, 1/2" PEX x 1/2" PEX x 1/2" PEX Q4755050 2.50" 1.53" 0.02 lbs. ❑ ProPEX EP Tee, 3/4" PEX x 3/4" PEX x 3/4" PEX Q4757575 3.30" 1.94" 0.05 lbs. ❑ ProPEX EP Tee, 1" PEX x 1" PEX x 1" PEX Q4751010 4.10" 2.47" 0.07 lbs. 0 ProPEX EP Tee, 11/4" PEX x 11/4" PEX x 11/4" PEX Q4751313 4.80" 3.22" 0.15 lbs. ❑ ProPEX EP Tee, 11/2" PEX x 11/2" PEX x 11/2" PEX Q4751515 5.80" 3.82" 0.25 lbs. ❑ ProPEX EP Tee, 2" PEX x 2" PEX x 2" PEX Q4752000 7.45" 4.79" 0.38 lbs. Installation Use the appropriate ProPEX Ring for PEX-a tubing. Refer to the Uponor AquaPEX® Professional Plumbing Installation Guide, AquaSAFETM Residential Fire Sprinkler Installation Guide or Uponor Radiant Installation Handbook for additional information. Standards CAN/CSA B137.5; ASTM F877; ASTM F1960 Codes IPC; UPC; NSPC; NPC of Canada Listings IAPMO 3558; ANSI/NSF 14- and 61-certified; HUD MR 1269; ICC ESR 1099; UL 1821; ULC/ORD-C199P Related Applications PEX-a Plumbing Systems Hydronic Radiant Heating and Cooling Systems Snow Melting Systems Turf Conditioning Systems Permafrost Prevention Systems AquaSAFE Fire Safety Systems Contact Information Uponor, Inc. Uponor Ltd. 5925 148"' Street West 2000 Argentia Road, Plaza 1, Suite 200 Apple Valley, MN 55124 USA Mississauga, ON L5N iWl CANADA Phone: (800) 321-4739 Phone: (888) 994-7726 Fax: (952) 891-2008 Fax: (800) 638-9517 www.uponorpro.com www.uponorpro.com 1ProPEX8 Is a registered trademark of Uponor, Inc. ProPEX`" is a trademark of Uponor Ltd. ProPEX® Engineered Polymer (EP) Reducing Tee uponof Submittal Information Revision E: June 8, 2012 Project Information Job Name: Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data Material: UDEL® Polysulfone, 20% Glass -reinforced (1/2 to 1") Acudel® Modified Polyphenylsulfone (11/4" to 11/2") Radel° R Polyphenylsulfone (2") Maximum Temperature (no pressure): 320°F (160°C) Max. Working Temperature/Pressure: 210OF (99°C) at 150 psi (1,034 kPa) Product Information and Application Use The ProPEX® Engineered Polymer (EP) Reducing Tee makes diverting connections for Uponor crosslinked polyethylene (PEX-a) tubing for use in hot and cold domestic potable water systems, residential fire sprinkler systems and hydronic radiant heating and cooling systems. Each end of the tee is manufactured with an Uponor ProPEX fitting for connections to Uponor AquaPEX® or Wirsbo hePEXT" tubing.' Note: Branch size is listed last in the part descriptions. ✓ Description Part Number Length (A) Height (B) Weight ❑ ProPEX EP Reducing Tee, 1/2" PEX x 1/2" PEX x 3/4" PEX Q4755575 2.86" 1.76" 0.03 lbs. ❑ ProPEX EP Reducing Tee, 3/4" PEX x 1/2" PEX x 1/2" PEX Q4757555 3.10" 1.70" 0.04 lbs. ❑ ProPEX EP Reducing Tee, 3/4" PEX x 1/2" PEX x 3/4" PEX Q4757557 3.10" 1.94" 0.04 lbs. ❑ ProPEX EP Reducing Tee, 3/4" PEX x 3/4" PEX x 5/s" PEX Q4757563 3.30" 1.85" 0.05 lbs. ❑ ProPEX EP Reducing Tee, 3/4" PEX x 3/4" PEX x'/2" PEX Q4757550 3.30" 1.70" 0.04 lbs. ❑ ProPEX EP Reducing Tee, 3/4" PEX x 3/4" PEX x 1" PEX Q4757710 3.64" 2.32" 0.08 lbs. ❑ ProPEX EP Reducing Tee, 1" PEX x 3/4" PEX x 3/4" PEX Q4751775 3.90" 2.24" 0.08 lbs. ❑ ProPEX EP Reducing Tee, 1" PEX x 3/4" PEX x 1" PEX Q4751751 3.90" 2.47" 0.08 lbs. ❑ ProPEX EP Reducing Tee, 1" PEX x 1" PEX x 1/2" PEX Q4751150 4.10" 2.00" 0.08 lbs. ❑ ProPEX EP Reducing Tee, 1" PEX x 1" PEX x 3/4" PEX Q4751175 4.10" 2.24" 0.09 lbs. ❑ ProPEX EP Reducing Tee, 11/4" PEX x 1" PEX x 3/4" PEX Q4751317 4.60" 2.73" 0.11 lbs. ❑ ProPEX EP Reducing Tee, 11/4" PEX x 1" PEX x 1" PEX Q4751311 4.60" 2.97" 0.12 lbs. ❑ ProPEX EP Reducing Tee, 11/4" PEX x 11/4" PEX x 3/4" PEX Q4751337 4.80" 2.73" 0.13 lbs. ❑ ProPEX EP Reducing Tee, 11/4" PEX x 11/4" PEX x 1" PEX Q4751331 4.80" 2.97" 0.14 lbs. ❑ ProPEX EP Reducing Tee, 11/2" PEX x 1" PEX x 3/4" PEX Q4751517 5.25" 3.06" 0.17 lbs. ❑ ProPEX EP Reducing Tee, 11/2 PEX x 1" PEX x 1" PEX Q4751511 5.25" 3.30" 0.18 lbs. ❑ ProPEX EP Reducing Tee, 11/2 PEX x 11/4" PEX x 3/4" PEX Q4751537 5.50" 2.65" 0.18 lbs. ❑ ProPEX EP Reducing Tee, 11/2" PEX x 11/4" PEX x 1" PEX Q4751531 5.50" 2.85" 0.19 lbs. ❑ ProPEX EP Reducing Tee, 11/2" PEX x 1'/4" PEX x 11/4" PEX Q4751533 5.50" 3.15" 0.21 lbs. ❑ ProPEX EP Reducing Tee, 11/2" PEX x 11/2" PEX x 3/4" PEX Q4751557 5.80" 3.06" 0.20 lbs. ❑ ProPEX EP Reducing Tee, 11/2 PEX x 11/2" PEX x 1" PEX Q4751551 5.75" 3.30" 0.21 lbs. ❑ ProPEX EP Reducing Tee, 11/2" PEX x 11/2" PEX x 11/4" PEX Q4751553 5.80" 3.56" 0.22 lbs. ❑ ProPEX EP Reducing Tee, 2" PEX x 11/2" PEX x 3/4" PEX Q4752575 6.62" 3.30" 0.30 lbs. ❑ ProPEX EP Reducing Tee, 2" PEX x 11/2" PEX x 1" PEX Q4752051 6.50" 3.40" 0.30 lbs. ❑ ProPEX EP Reducing Tee, 2" PEX x 11/2" PEX x 11/4" PEX Q4752053 6.62" 3.80" 0.34 lbs. ❑ ProPEX EP Reducing Tee, 2" PEX x 11/2" PEX x 11/2" PEX Q4752055 6.62" 4.10" 0.35 lbs. ❑ ProPEX EP Reducing Tee, 2" PEX x 2" PEX x 3/4" PEX Q4752275 6.93" 3.30" 0.34 lbs. ❑ ProPEX EP Reducing Tee, 2" PEX x 2" PEX x 1" PEX Q4752210 6.93" 3.40" 0.36 lbs. ❑ ProPEX EP Reducing Tee, 2" PEX x 2" PEX x 11/4" PEX Q4752213 6.62" 3.80" 0.37 lbs. ❑ ProPEX EP Reducing Tee, 2" PEX x 2" PEX x 11/2" PEX Q4752215 7.13" 4.10" 0.44 lbs. Installation Use the appropriate ProPEX Ring for PEX-a tubing. Refer to the Uponor AquaPEX® Professional Plumbing Installation Guide, AquaSAFETM Residential Fire Sprinkler Installation Guide or Uponor Radiant Installation Handbook for additional information. Standards Codes Listings CAN/CSA B137.5; ASTM F877; IPC; UPC; NSPC; NPC of Canada NSF U.P. CODE; ANSI/NSF 14- and 61-certified; HUD MR 1269; ASTM F1960 ICC ESR 1099; UL 1821 and ULC/ORD-C199P (except Q4757563) Related Applications Contact Information PEX-a Plumbing Systems Uponor, Inc. Uponor Ltd. Hydronic Radiant Heating and Cooling Systems 5925 148u' Street West 2000 Argentia Rd., Plaza 1, Ste. 200 Snow and Ice Melting Systems Apple Valley, MN 55124 USA Mississauga, ON L5N 1W1 CANADA Turf Conditioning Systems Phone: (800) 321-4739 Phone: (888) 994-7726 Permafrost Protection Systems Fax: (952) 891-2008 Fax: (800) 638-9517 AquaSAFE Fire Safety Systems www.uponorpro.com- - www.uponorpro.com 1ProPEX® Is a registered trademark of Uponor, Inc. ProPEX`" Is a trademark of Uponor Ltd. ProPEX® Engineered Submittal Information Revision D: June 8, 2012 Project Information Job Name: Polymer (EP) Elbow Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data Material: Maximum Temperature (no pressure): Maximum Working Temperature/Pressure: UDEL® Polysulfone, 20% Glass -reinforced (1/2 to 1") Acudel® Modified Polyphenylsulfone (11/4" to 11/2") Radel° R Polyphenylsulfone (2") 320°F(1600C) 210OF (99°C) at 150 psi (1,034 kPa) Product Information and Application Use The ProPEXO Engineered Polymer (EP) Elbow makes 90-degree connections for Uponor crosslinked polyethylene (PEX-a) tubing for use in hot and cold domestic potable water systems, residential fire safety and hydronic radiant heating and cooling systems. Each end of the elbow is manufactured with an Uponor ProPEX fitting for connections to Uponor AquaPEX® or Wirsbo hePEXTM tubing.' uponof Description Part A B Weight Number ❑ ProPEX EP Elbow, 1/2" PEX x 1/2" PEX Q4760500 1.30" 1.30" 0.02 lbs. ❑ ProPEX EP Elbow, 3/4" PEX x 3/4" PEX Q4760750 1.60" 1.60" 0.03 lbs. ❑ ProPEX EP Elbow, 1" PEX x 1" PEX Q4761000 2.10" 2.10" 0.07 lbs. ❑ ProPEX EP Elbow, 11/4" PEX x 11/4" PEX Q4761250 2.45" 2.45" 0.11 lbs. ❑ ProPEX EP Elbow, 11/2" PEX x 11/2" PEX Q4761500 2.77" 2.77" 0.18 lbs. ❑ ProPEX EP Elbow, 2" PEX x 2" PEX_ Q4762000 3.76" 3.76" 0_.3.0 lbs. Installation Use the appropriate ProPEX Ring for PEX-a tubing. Refer to the Uponor AquaPEX® Professional Plumbing Installation Guide, AquaSAFE'm Residential Fire Sprinkler Installation Guide or Uponor Radiant Installation Handbook for additional information. Standards CAN/CSA B137.5; ASTM F877; ASTM F1960 Codes IPC; UPC; NSPC; NPC of Canada Listings IAPMO 3558; ANSI/NSF 14- and 61-certified; HUD MR 1269; ICC ESR 1099; UL 1821; ULC/ORD-C199P Related Applications Contact Information PEX-a Plumbing Systems Uponor, Inc. Uponor Ltd. Hydronic Radiant Heating and Cooling Systems 5925 148i" Street West 2000 Argentia Road, Plaza 1, Suite 200 Snow Melting Systems Apple Valley, MN 55124 USA Mississauga, ON L5N iWi CANADA Turf Conditioning Systems Phone: (800) 321-4739 Phone: (888) 994-7726 Permafrost Prevention Systems Fax: (952) 891-2008 Fax: (800) 638-9517 AquaSAFE Fire Safety Systems www.uponorpro.com www.uponorpro.com 1ProPEX8 is a registered trademark of Uponor, Inc. ProPEX'" is a trademark of Uponor Ltd Uponof ProPEXO Fire Sprinkler Adapter Submittal Information Revision B: March 17, 2009 Project Information Job Name: Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: ,approved By: Technical Data Material: 300 Series Stainless Steel Product Information and Application Use Use the ProPEXO Fire Sprinkler Adapter in conjunction with the appropriate sprinkler to provide a multi -purpose residential fire sprinkler system'. For residential applications, the system is installed with the cold -potable portion of the Uponor plumbing system. Make connections with Uponor ProPEX fittings. These fittings are designed for use only with 3/4" or 1" AquaPEX® White tubing in the Uponor AQUASAFE® Looped System. ✓ Description NPart umber A B C D E Weight ProPEX Fire Sprinkler Adapter, 3/4" PEX x 1/2" FNPT Q7517550 0.75" 1.88" 2.50" 1.82" 1.41" 0.268 lbs. ProPEX Fire Sprinkler Adapter, 1" PEX x 1/2" FNPT Q7511050 0.75" 1.88" 2.50" 2.06" 1.54" 0.408 lbs. Installation Use appropriate ProPEX Ring for connecting the tubing. Refer to the AquaPEX Installation Handbook or the Uponor AQUASAFE® Installation Guide for additional information. Standards CAN/CSA B137.5; ASTM F877; ASTM F 1960 Codes IPC; UPC; NSPC; IRC; IMC; NPC of Canada Listings ANSI/NSF 14- and 61-certified; U.P. Code; ICC ESR 1099; HUD MR 1269; UL 1821; ULC/ORD - C 199 P Related Applications PEX-a Plumbing Systems AQUASAFE Fire Safety Systems Contact Information Uponor, Inc. 5925 148"' Street West Apple Valley, MN 55124 USA Phone:(800) 321-4739 Fax: (952) 891-2008 www.uponor-usa.com Uponor Ltd. 2000 Argentia Rd., Plaza 1, Ste. 200 Mississauga, ON L5N 1W1 CANADA Phone: (888) 994-7726 Fax: (800) 638-9517 www.uponor.ca 'ProPEXO Is a registered trademark of Uponor, Inc. ProPEX"" Is a trademark of Uponor Ltd. The Design Criteria for Sloped & Sloped Beamed Ceilings in NFPA 13D One and Two Family Dwellings & Manufactured Homes Has Changed. to L L L12 C LISTED AREA OF CORRESPONOSI L -THE MAXIMUM LISTED SPRINKLER SPACING. LENGTH (V-0' MAXIMUM) (8'-0'MINIMUK . L12 ONE HALF THE MAXIMUM LISTED SPRINKLER SPACING (S-0' MAXIMUM) (4'-O'MINIMUM) W . THE MAXIMUM LISTED SPRINKLER SPACING. WIDTH (10'4� A - 3'-0' MAXIMUM. B = RANGE: 2112 (9.41cSt8112 (33.71 L C-8'•0'MINIMUM. no•enre A•T•p UMMMMwUM 03$FGM nev.�a n A Tentative Interim Amendment (TIA No.1028R) to NFPA 13D for 2010 has been issued by the NFPA Standards Council. Testing supported by The Fire Protection Research Foundation indicates that residential sprinklers listed for applications with smooth, flat ceilings can meet the stated purpose in NFPA 13D standards when installed on a sloped or sloped and beamed ceiling. Sloped and Sloped/Beamed Ceilings, under certain conditions, can now be protected with residential sprinklers based upon a maximum two (2) sprinkler demand that has the same flow rate as the sprinklers smooth, flat ceiling listing. The TIA No.1028R revises NFPA 13D - 2010 edition sections'8.1.2, 8.1.3, A.8.1.2, and A.8.1.3. Please read and adhere to these sections for the complete new design criteria. A brief recap: The sprinklers in the design area shall be all of the sprinklers in a compartment, up to a maximum of two, which require the greatest demand for: e Smooth, flat ceilings to a maximum 24 feet in height. • Smooth, ceilings (with no beams) sloped up to 8/12 and a maximum ceiling height of 24' above the floor. a A ceiling with beams up to 14" deep sloped up to 8112 and a maximum ceiling , height of 24' above the floor. Pendent sprinklers shall be installed under the °beams and the compartment cannot exceed 600 square feet. e A ceiling with beams of any depth sloped up to 8/12 and a maximum ceiling height of 24' above the floor. Sidewall or pendent sprinklers shall be installed in each pocket formed by the beams and the compartment cannot exceed 600 square feet. All Reliable residential sprinklers can be used for these applications based upon the spacing, flow, and pressure as listed for smooth and flat ceilings. (See Bulletins: 135, 006, 033 and 032): -' This TIA is for 13D applications only. Changes to 13R will be in the 2013 Edition. Our special 10' x 10' spacing listings for sloped ceilings are still advantageous for 13R installations. (See Table 9, Bulletin 035). For any questions, please contact Technical Services at 1-800-55-RASCO. The Reliable Automatic Sprinkler Co., Inc. • Manufacturer & Distributor of Fire Protection Equipment wwvAreliablesprinklercom • 1.800A31.1588