Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD20180021 (5)
OF ED MD�� CITY OF EDMONDS 121 5TH AVENUENORTH - EDMONDS, WA 98020 �6�. 1890 PHONE: (425) 771-0220 - FAX: (425) 771-0221 Expiration Date: 01/24/2019 Parcel No: 27033600109600 EDMONDS 2JGLLC WESTERN STATES FIRE PRTCTN CO WESTERN STATES FIRE PRTCTN CO C/O 2JG LLC C/O RUSSELL BECKER C/O RUSSELL BECKER 7500 ROOSEVELT WAY NE 14690 NE 95TH ST, UNIT 1 O1 14690 NE 95TH ST, UNIT 101 SEATTLE, WA 98115 REDMOND, WA 98052 REDMOND, WA 98052 (425)881-0100 (425)881-0100 LICENSE #: WESTESF1360F EXP:01/19/2019 Install new NFPA 13 D fire sprinkler system w/28 heads in new SFR. Stand alone system VALUATION: $0 PERMIT TYPE: Residential PERMIT GROUP: 30 - Fire Sprinkler GRADING: N CYDS: 0 TYPE OF CONSTRUCTION: RETAINING WALL ROCKERY: OCCUPANT GROUP: OCCUPANT LOAD: FENCE: ( 0 X 0 FT.) CODE: OTHER: ------- OTHER DESC: ZONE: NUMBER OF STORIES: 0 1 VESTED DATE: NUMBER OF DWELLING UNITS: 0 JLOT #: EXIST]ING AREA BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 1 POS ED AREA BASEMENT: 0 1 ST FLOOR: 0 2ND FLOOR: 0 3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 13RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0 BEDROOMS:0 BATHROOMS:O BEDROOMS:O BATHROOMS:0 FRONTSETRACK SIDESEIFBACK REQUIRED: PROPOSED: REQUIRED: PROPOSED: REQUIRED: PROPOSED: HEIGHT ALLOWED:O PROPOSED:O REQUIRED: PROPOSED: SETBACK NOTES: I AGREE TO COMPLY WITH CITY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMENS COMPENSATION INSURANCE AND RCW 18:27. THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID. i' Print �n IZG WGZ[�21;Ct.�2Gi'i/Z7/Zola i. Date Released By ATTENTION IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF OCCUPANCY HAS BEEN GRANTED. UBC109/ IBCI 10/ IRC110. FIRE = APPLICANT = ASSESSOR = CITY STATUS: ISSUED BLD20180021 • Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of the building or structure. Check the job card for all required City inspections including final project approval and final occupancy inspections. • Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") from adopted codes. ordinances or policies must be specifically requested in NATiting and be called out and identified. Processing fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable. • Approval of any plat or plan containing provisions which do not comply with city code and for which a variance has not been specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision ofcity code or state law does not approve any items not to code specification. • Sound/Noise originating from temporary construction sites as a result ofconstructionactivity are exempt fi-omthe noise limits of FCC Chapter- 5.30 only during the hours of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to FCC 5.30.120. • Applicant, on behalf of his or her spouse, heirs. assigns. and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all clairns for damages of whatever nature, arising directly or indirectly from the issuance for this permit. Issuance ofthis permit shall not be deemed to modity, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRIVATE PROPERTY ONLY. ANY CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT TIME LIMIT: SEE ECDC 19.00.005(A)(6) BUILDING !ENGINEERING (425) 771-0220 EXT. 1326 Go to. www.edmondswa.gov 12. Then: Services 1 3. Then: Permits/Development 4. Then: Online Permit Info j 5: If you don't have one already, create a login (upper right hand corner) 6: Schedule vour inspection Building Department Inspections are now scheduled online. If you have difficulties, please call the Building Department front desk for assistance during office hours. (425) 771-0220 FIRE (425) 775-7720 PUBLIC WORKS (425) 771-0235 RECYCLING (425) 275-4801 When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection being requested, Contact Name and Phone Number, Date Preferred, and whether you prefer morning or afternoon. • F-Fire Sprinkler Insulation • F-Fire Sprinkler Bucket Test • F-Fire Sprinkler Pressure'Fest • F-Fire Sprinkler Acceptance F-Fire Final DEVELOPMENT SERVICES RESIDENTIAL BUILDING PERMIT APPLICATION 4t.1 121 51h Avenue N, Edmonds, WA 98020 City of Edmonds Phone 425.771.0220It Fax 425.771.0221 PLEASE REFER TO THE RESIDENTIAL BUILDING CHECKLIST FOR SUBMITTAL REQUIREMENTS PROJECT ADDRESS (Street, Suite #, City State, Zip): 9340 232ND ST SW EDMONDS, WA 98020 Parcel #: 27033600109600 Subdivision/Lot #: 3 Project Valuation: $ 7,921.00 APPLICANT: WESTERN STATES FIRE PROTECTION Phone: 425-881-0100 Fax: 425-881-3030 Address (Street, City, State, Zip): 14690 NE 95TH ST #101 REDMOND, WA 98052 E-Mail Address: JERRY.GOIN@WSFP.US PROPERTY OWNER: 2JG LLC Phone: 206-920-2903 Fax: Address (Street, City, State, Zip): 7500 ROOSEVELT WAY NE SEATTLE, WA 98115 E-Mail Address: LENDING AGENCY: Phone: Fax: Address (Street, City, State, Zip): E-Mail Address: CONTRACTOR:* 14690 NE 95TH ST #101 REDMOND, WA 98052 Phone: 425-881-0100 Fax: 425-881-3030 Address (Street, City, State, Zip): E-Mail Address: JERRY.GOIN@WSFP.US *Contractor must have a valid City of Edmonds business license prior to doing work in the City. Contact the City Clerk's Office at 425.775.2525 WA State License #/Exp. Date: WESTESF136QF / 12-31-17 City Business License #/Exp. Date: NR-023343 / 12-31-18 DETAIL THE SCOPE OF WORK: INSTALL NEW NFPA 13D FIRE SPRINKLER SYSTEM W/ 28 HEADS IN NEW SFR PROPOSED NEW SQUARE FOOTAGE FOR THIS PROJECT: Basement: -sq. ft. Select Basement Type: Finished Ll Unfinished Li 1" Floor: 1287 s . ft. Garage/Carport: s . ft. 2" Floor: 1603 s . ft. Deck/Cvrd Porch/Patio: s . ft. Bedrooms # 4 Full-3/4 Bath # 3 Half -Bath # Other: sq. ft. Fire Sprinklers: Yes Lx No LJ Retaining Wall: Yes LJ No LJ Grading: Cut cu. yds. Fill cu.yds. Cut/Fill in Critical Area: Yes No I declare under penalty of perjury laws that the information I have provided on this form/application is true, correct and complete, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Edmonds. Print Name: JERRY GOIN Owner ❑ Agent/Other ❑ (specify): CONTRACTOR Signature: Date: 1- 5 -18 FORM A LABuilding New Folder 2010\DONE & x-ferred to L-Building-New driveTorm A2014.docx Updated: 1/17/2014 RjjljHydraulic Summary Job Number. KH1075 Job . r�aaiuo,rDc, Aab NumEa Dye KH1075 JERRY GOIN AbName: YOUNG SHORT PLAT LOT 3 State CartlR..O.VU eNumber WESTESF136OF Ad&-1 9340 232ND ST SW A)-) CITY OF EDMONDS Ad*— 2 A b Ske&L*7 B YOUNG SHORT PLAT LOT 3 Aft— 3 EDMONDS, WA 98020 D—ftNaru- YOUNG SHORT PLAT LOT 3 - KH 1075.cad System Remote Areas) MW D-ma W" SpWdw oats 0--p- y Joe sum. 4.9 K-Factor 13.00 at 7.039 Residential Na-eAS—N Sa-e 100.00 Dm-4 0.050gpm/ft2 Arw dAppka9w 256.00ft2 (Actual 274.50ft2) A0M.* Now Supple- Number of - SVh;*C.$.AM C—W Pm Svhtd. Node Flow m 2 256.00112 A"ftk RmAL Prevu- Fm Ran A-(a)A*a To -bat R-moMAma �wwwws•wwwwwwww�wwwwwws•w�wwwww� ■ WASHINGTON STATE ■ CERTIFICATE OF COMPETENCY ■ FIRE PROTECTION SPRM XLER SYSTEMS ■ ■ ■ ANTHONY MICHAEL GEIST 6781-0715-C LEVEL 3 j ■ WESTERN STATES FIRE PROTECTION CO ■ WwH -eSo— 100.00 j WESTESF136QF ■ ■ SyWm Row Demand Trial WeM R-eWmd Srdal-p Now Mavand) 26.07 126.07 ■ ■ � -01/04/2018 Min i r-m MariPw--me WWI— LooX 0.000 SlSnatara Data 1201118 g' tiwwww�wwwwwwww�wwwwww•ww www�i M"d Vebely Abov Gmnd 9.68 between nodes 4 and 84 Mald— V-bdty Under Dmund 2.65 between nodes 3 and 4 Vd--. 'I dwat Piq- velum- wally of Dry Plea 70.43gal Supplies Hose Flow Static Residual Flow Available Total Demand Required Safety Margin Node Name m si si m si m (psi)(psi) 1 Water Supply 100.00 61.000 20.000 500.00 57.795 126.07 1 31.774 26.021 RECEIVED JAN 05 2017 cffy COP BUILDING Contractor CeM-dor Nunbm KH1075 C- Name Jerry Goin Centsd TMM Project Manager Nam. aCantradm: Western States Fire Protection Co. Ph— 425-881-0100 EM-rRbn Add— / 14690 N.E. 95th Street, Unit 101 FAX 425-881-3030 mew 2 Redmond, WA 98052 E+edl jerry.goin@wsfp.us Aft— I wW-yb & © MRACAD, Inc. ay AutoSPRINK®12 v12.0.59.0 1/4/2018 9:44:23AM Page 1 �jjsjHydraullcGraph Job Number: KH1075 Report Desed tion: Residential Water Supply at Node 1 100 90 80 70 tatic Pressure 61.000 60 d � o_ 40 .07 31.774 30 126.07 with hose streams 20 .00 @ 20.000 tern demand curve 10 0 �100 200 3D0 400 500 600 700 800 9D0 10D0 Water flow, gpm Myd—lk Graph Water Supply at Node 1 MO. Rogue 61.000 Noku.l: Re..ue 20.000 @ 500.00 Anode Pne.ue n The of Test 57.795 @ 126.07 sw.eo.o.oe . 31.774 @ 26.07 Sy-1—. (. d..*—Mo..,ce.t l—) 31.774 @ 126.07 & 0 M.E.P.CAD, Inc. J1 AutoSPRINK®12 A2.0.59.0 1/4/2018 9:44:25AM Page 2 IRSummary Of Outflowina Devices I Job Number: KH1075 & © M.E.P.CAD, Inc. 11 AutoSPRINKS 12 02.0.59.0 1/4/2018 9:44:27AM Page 4 is Node Analysis Job Number: KH1075 Node Elevation Foot Fittings Pressure(psi) Dischar e m 1 12'-0 S 31.774 26.07 232 19'-6 S r -7.039 7.039 13.00 233 19'-6 S r -7.116 7.116 13.07 2 12'-0 WMV -4.000 30.107 3 EE , BOR 30.804 4 E-3-0 1'-10 28.674 26 0'0T5-0 '2'-0 9.652 27 5-0 9.644 49 -O ,Tr -0FV 15.889 65 20'-0 Tr 1'-0, T 5'-0 8.431 84 6'-0 21.691 92 20'-0 T 5'-0 7.347 & © M.E.RCAD, Inc. r111AutoSPRINKO 12 V12.0.59.0 1/4/2018 9:44:28AM Page 5 Hydraulic Analysis Job Number: KH1075 Report Description: Residential Pipe Type Diameter Flow Velocity HWC Friction Loss Length Eq. Length Total Length Pressure Summary Downstream Elevation Discharge K-Factor Pt Pn Fittings Upstream w•••••Route I..... DR 1.1010 13.00 4.38 150 0.030666 5'-2 12'-0 17'-2 Pf Pe , Pv 0.526 -0.217 232 19'-6 13.00 4.9 7.039 Sprinkler, 92 20'-0 7.347 E T-0 , T 5'-0 BL 1.1010 26.07 8.79 150 0.111114 9'-9 9'-9 Pf Pe Pv 1.084 92 20'-0 13.07 7.347 Flow (q) from Route 2 65 20'-0 8.431 BL 1.1010 15.47 5.21 150 0.042313 16'-6 10'-0 26'-6 Pf Pe Pv 1.121 65 20'-0 8.431 Tr(1'-0) 26 20'-0 9.552 4Tr 1'-0 , T 5'-0 BL 1.1010 2.84 0.96 150 0.001836 27'-11 22'-0 49'-11 Pf Pe Pv 0.092 26 20'-0 9.552 T(5'-0) 27 20'-0 9.644 3T 5'-0 , 2T V-0 BL 1.1010 13.44 4.53 150 0.032607 25'-8 33'-0 58'-8 Pf Pe Pv 1.912 4.334 27 20'-0 10.60 9.644 Flow (q) from Route 3 49 10'-0 15.889 2T 5'-0 , 3E 7'-0 , 2Tr 1'-0 BL 1.1010 26.07 8.79 150 0.111114 22'-5 14'-0 36'-5 Pf Pe Pv 4.042 1.760 49 10'-0 12.63 15.889 Flow (q) from Route 4 84 V-0 21.691 2Tr 1'-0 , T 5'-0 , E 7'-0 CM 1.0490 26.07 9.68 120 0.212510 4'-2 4'-2 Pf Pe Pv 5.182 1.800 84 6'-0 21.691 4 1'-10 28.674 f -0.000 , BFP -4.300 UG 2.0030 26.07 2.65 150 0.006027 4'-10 2'-0 V-10 Pf Pe Pv 0.041 2.089 4 V-10 28.674 3 4-0 30.804 EE 2'-0 , BOR UG 2.0030 26.07 2.65 150 0.006027 300'-0 300'-0 Pf Pe Pv 5.808 -6.505 3 4-0 30.804 2 17-0 30.107 WMV -4.000 BL 1.1010 26.07 8.79 150 0.111114 15'-0 15'-0 Pf Pe Pv 1.667 2 12'-0 30.107 1 12'-0 31.774 Water Supply 100.00 Hose Allowance At Source 1 126.07 w•••••Route 2••••• DR 1.1010 13.07 4.40 150 0.030978 4'-6 10'-0 14'-6 Pf 0.448 Pe -0.217 Pv 233 19'-6 13.07 4.9 7.116 Sprinkler, 92 20'-0 7.347 2T 5'-0 w•••••Route 3•-••• BL 1.1010 10.60 3.57 150 0.021024 37'-8 Pf 1.213 65 27 20'-0 20'-0 8.431 9.644 T(5'-0) 5Tr 1'-0 , 2T 5'-0 20-0 57-8 Pe Pv w•••••Route 4••••• BL 1.1010 12.63 4.26 150 0.029084 28'-11 2003. 26 49 20'-0 101-0 9.552 15.889 4E 7'-0 , 2T 5'-0 , 2Tr 1'-0 40'-0 68'-11 �Pf Pe Pv 4.334 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) / Actual Inside Diameter 4'87 l Schedule 40 Steel Pipe Inside Diameter ) Schedule Factor C Value Multiplier Value Of C 100 Multiplying Factor 0.713 130 140 1.16 1.33 150 1.51 r© M.E.P.CAD, Inc. Oil AUtoSPRiNK®12 v12.0.59.0 1/4/2018 9:44:30AM Page 6 J110[flydraulic Analysis Job Number. KH1075 v Kepon uescnption: Kesidential Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length Pipe Type Legend Units Legend Fittings Legend AO Ann -Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain Discharge gpm BalV Ball Valve DR Drop Velocity fps BFP Backflow Preventer DY Dynamic Pressure psi BV Butterfly Valve FM Feed Main Length Foot C Cross Flow Turn 90' FR Feed Riser Friction Loss psi/Foot cpig Coupling MS Miscellaneous HWC Hazen -Williams Constant Cr Cross Run OR' Outrigger Pt Total pressure at a point in a pipe CV Check Valve RN Riser Nipple Pn Normal pressure at a point in a pipe DeIV Deluge Valve SP Sprig Pf Pressure loss due to friction between points DPV Dry Pipe Valve ST Stand Pipe Pe Pressure due to elevation difference between indicated points E 90° Elbow UG Underground Pv Velocity pressure at a point in a pipe EE 45° Elbow Eel 11'Y.° Elbow Ee2 22%* Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90` FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Hose Hose HV Hose Valve Hyd Hydrant LIE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap © M.E.P.CAD, Inc. ,RjAutoSPRINK®12 02.0.59.0 1/4/9n1R c•aa•snAM P.-70 WiChock Point Gaune Data I Job Number: KH1075 & 0 M.E.P.CAD, Inc. ifl AutoSPRINK®12 v12.0.59.0 1/4/2018 9:44:32AM rage a Tag Job Number: KH1075 Job YOUNG SHORT PLAT LOT 3 9340 232ND ST SW EDMONDS, WA 98020 Design Basis Occupancy: Total Sprinklers: Number Of Sprinklers Calculated: K-Factor: Orifice Size: Design Density: Average Density: Area of Application: Demand At Base Of Riser (BOR) Total Demand Flow(gpm): Pressure(psi): Residential 35 2 4.9 0.5 0.050gpm/ft2 0.095gpm/ft2 256.00ft2 (Actual 274.50ft2) 26.07 30.804 Water Supply Information At Time Of Design Static Pressure(psi): 61.000 Residual Pressure(psi): 20.000 Supply Flow(gpm): 500.00 Total Demand Flow(gpm): Total Demand Pressure(psi): 126.07 31.774 & 0 KE.P.CAD, Inc. M AutoSPRINK®12 v12.0.59.0 1/4/2018 9:44:33AM Page 9 & @ M.E.P.CAD, Inc. MAutoSPRINK®12 vl2.0.59.0 1/4/2018 9:44:35AM Page lu ES-A-2000B Series 2000B A& A M E S Double Check Valve Assemblies FIRE&WATERWORKS Sizes: '/2" — 2" (15 — 50mm) Features • Ease of maintenance with only one cover • Top entry • Replaceable seats and seat discs • Modular construction • Compact design • '/2" — 2" (15 — 50mm) Cast bronze body construction • Top mounted ball valve test cocks • Low pressure drop • No special tools required • Y2" — 1 " (15 — 25 mm) have tee handles Available Models Suffix: B - Quarter turn ball valves LBV - less ball valves SH - stainless steel ball valve handles HC - 21h" inlet/outlet fire hydrant fitting (2" valve) Pressure — Temperature Temperature Range: 33"F —140"F (0.5°C — 60°C) Maximum Working Pressure: 175psi (12.1 bar) Standards AWWA Std. C510, IAPMO PS31 2" 20MB HC (50mm) i!nr '/a" 2000E (20mm) Series 2000E Double Check Valve Assemblies shall be installed at referenced cross - connections to prevent the backflow of polluted water into the potable water supply. Only those cross -connections identified by local inspection authorities as non -health hazard shall be allowed the use of an approved double check valve assembly. Check with local authority having jurisdiction regarding vertical orientation, frequency of testing or other installation requirements. These valves meet the requirements of ASSE Std. 1015 and AWWA Std. C510 and are approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Specifications A Double Check Valve Assembly shall be installed at each noted location. The assembly shall consist of two positive seating check modules with captured springs and rubber seat discs. The check module seats and seat discs shall be replaceable. Service of all internal components shall be through a single access cover secured with stainless steel bolts. The assembly shall also include two resilient seated isolation valves and four top mounted, resilient seated test cocks. The assembly shall meet the requirements of ASSE Std. 1015 and AWWA Std. C510. Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be an Ames Company Series 2000B. Approvals ,�V,ssl& C us c us 1015 B64.5 3/d" - 2" (LBV Models Only) Approved by the Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California. LBV models not listed. Horizontal and vertical "flow up" approval on all sizes. Job Name Contractor Job Location Engineer Approval Approval Contractor's P.O. No. Representative Ames product specifications in U.S. customary units and metric are approbmate and are provided for reference only. For precise measurements, please contactAmes Technical Service. Ames reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.amesfirewater.com Dimensions - Weights Suffix HC - Fire Hydrant Fittings dimension "A" = 231h" (594mm) SIZE 1 DIMENSIONS in. mm A in. mm in. B mm C in. mm F in. mm 6 In. mm H in. mm In. 1 mm lbs. kgs. 1h 15 10 254 4% 117 27/6 62 5 127 33h 85 2M6 59 21/6 52 4.5 2 % 20 11% 282 4 102 3% 79 On 157 37/6 87 2% 54 15/16 33 5 2.3 1 25 1314 337 51h 130 4 102 71h 191 3% 85 1 V/16 43 11 Y6 43 12 5.4 1 % 32 163 416 5 127 35/16 84 91h 241 5 127 3 76 2 50 15 6.8 11h 40 16% 425 47A 124 31h 89 93 4 248 513/16 148 31/a 79 211 16 68 15.86 72 2 50 191/2 495 61/4 159 4 102 13% 340 6% 156 37/16 87 211/6 68 25.75 11.7 Strainer sold separately Capacities As compiled from documented Foundation for Cross -Connection Control and Hydraulic Research at the University of Southern California lab tests. ATypical maximum system flow rate V.5 feet/sec., 2.3 meters/sec.) kPa psi 112" (15mm) N 83 12 O 69 10 N 55 6 41 6 �i 28 4 d 14 2 a` 0 0 0 2 4 6 8 10 12 gpm AP 0 7A 15.2 22.8 30A 38 45.6 Ipm 5 7.6 10 fps 1.5 2.3 3.0 mps Flow Rate kPa psi ai 152 22 124 18 96 14 7 69 10 Ii 41 6 14 2 I 31-11 10JA ....1 I. ...... I gpm kPa psi 96 14 83 12 0 69 10 J 55 8 j 41 6 28 4 a 14 2 0 0 AP 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 0 38 76 114 152 190 228 206 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate 1 ih11(40mm) kPa psi 83 12 H 69 10 O 55 8 .j 41 6 28 4 14 2 li 0 o pp0 110 120 gpm 10 20 30 40 50 60 70 80 90 100 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps AP 0 19 38 57 76 95 114 133 152 171 190lpm Flow Rate 7.6 2.3 15 4.6 fps mps kPa psi 2" (50mm) Flow Rate N 83 12 w kPa psi Q 111 (25mm) 0 69 10 rn 110 16 -j 55 8 J 83 12 1 7 41 6 y 69 10 0)28 4 55 3 8 H 41 s ar a 14 2 0 0 li 28 2 0 25 50 75 100 125 150 175 200 gpm DP 0 95 190 285 380 475 570 665 760 Ipm 0 5 10 15 20 25 30 35 40 45 60 55 60 gpm 5 7.5 10 15 fps AP 0 19 38 57 76 95 114 133 152 171 190 209 228Ipm 1.5 2.3 3.0 4.6 mps 5 7.6 10 15 fps Flow Rate 1.5 2.3 3.0 4.6 mps Flow Rate Q M E S FIRE& WATERWORKS wvvw.amesfirewater.com A Watts Water Technologies Company ES-A-2000B 1322 USA: Backfiow- Tel: (916) 928-0123 • Fax: (916) 928-9333 Control Valves- Tel: (713) W-0688 • Fax: (713) 944-9445 Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 © 2013 Ames Fire & Waterworks Bulletin 425 Rev. B CO. .. ® ReliableCD Riser — N M ---IlablResidentialCD CO Reliable Riser - Residential 1" (25mm),1/" (40mm), and 2" (50mm) sizes. For use in NFPA 13D and 13R Residential Systems Features: 1. Stainless Steel body construction. 2. All brass trim. 3. Factory assembled. 4. Factory pressure tested at 200 psi. (13.8 bar). 5. Choice of trim: • Basic Trim (Fig. 1). • Basic Trim with Pressure Relief Kit (Fig. 2). • Basic Trim with Test and Drain Valve (Fig. 3). • Basic Trim with Test and Drain Valve and Pressure Relief Kit (Fig. 4). 6. Choice of mounting options: • Supply / System lines support. • Support Bracket (to stud) (Figs. 5 & 6). • Recessed or Flush mount (to wood panel) (Fig. 7). 7. NPT (female x female) or tapered metric (female x female) connections. 8. Slim design allows for easy installation within 2" x 4" on 16" centers wood frame construction. 9. Dedicated UL Listed and ULC Listed Water Flow Detector assures optimum sensitivity. Water Flow Detector is factory installed with a metallic, weatherproof cover. Triggeringflow rate is 4(15) GPM(LPM) to 10(38)GPM(LPM). Approvals & Listings 1. Listed by Underwriters Laboratories Inc. and ULC Listed. 2. NYC MEA 258-93-E rig. i ease Trim Hg. 2 Base Trim with Pressure Relief Kit rfg. 3 Base Trim with Test and Drain Valve Mg. 4 tsase Trim Wnn Test and Dram Valve & Pressure Relief Kit The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Optional Trims - Technical Data: Description Basic Trim Basic Trim with Pressure Basic Trim with Test and Basic Trim with Test and Drain Relief Kit Drain Valve Valve & Pressure Relief Kit Tape Out Dimensions weWr Dimensions Wei ht* Dimensions Weight* Dimensions Wei ht" Dirrtertsion Manifold size: Lbs Lbs Lbs Lbs inch inch inch inch inch inch inch inch (kgs) inch mm) (mm)(kgs) mm(mm)(kgs) mm(mm)(kgs) mm mm mm 1" 11 8y, 7.3 13 j' 11 8.7 11 14}4 9.0 15 14}4 10.6 8 }4 25mm 279 222 3.32 343 279 3.95 279 362 4.09 381 362 4.82 210 1y" 11 9}4 8.3 13}' 11}' 10.5 11 14� 9.7 15 143/ 11.2 8 }4 40mm (279) (235) (3.77) (343) (292) (4.77) (279) (375� (4.41) (381) (375) (5.09) (210) 2 11 9�4 8.8 13}2 12 11.1 11 15, 4 10.5 15 15 j/, 12.2 8 }4 50mm 279 248 4.00 343 305 5.05 279 387 4.77 381 387 5.55 210 * Support Bracket Kit (optional) - 1 lb (0.45 kg) All Reliable Risers have a 1" NPT drain port. Basic Trim With Pressure Relief Kit Basic Trim whh Test and Drain Pressure Relief Kh Water Water B Press. Relief Pressure Gau a g Press. Relief Pressure d (Opt.) Kit (Opt.) GaugManifold System Manifold System 0Z Support Body � Suport Bracket Body 4 Bracket M C Take -Out) C A A (Take -Out) iy Supply (1 Supply Drain Drain Test and Drain Drain Valve Valve Water Flow Detector Water Flow Detector (Contact Ratings: t0A@ 125250 VAC 2.5A@ 24VDC) (Contact Ratings: 10A @ 125250 VAC 2.5A @ 24VDC) Product Description: The Reliable -Risers come factory assembled with all of the necessary accessories for a cost effective, yet complete riser solution. Reliable -Rises are [UL Listed][ULC Listed] [NYC Approved MEA 258-93-E] for horizontal or vertical installations as a one-piece, factory assembled unit for use in NFPA 13D and 13R residential sys- tems. The riser manifold assembly shall consist of a (choose one): • 1" (25 mm) cast, non -welded stainless steel body with 1" female NPT or IS07-Rc1-11 threaded end connections. Fig. 5 • 1-y" (40 mm) cast, non -welded stainless steel body with 1-y" female NPT or IS07-Rc1.5-11 threaded end connections. • 2" (50 mm) cast, non -welded, stainless steel body with 2" female NPT or IS07-Rc2-11 threaded end connections. All of these manifold sizes have cast -on lettering that clearly identifies the manifold's pipe size, flow direction, UL Listing/ ULC Listing, and the test and drain outlet. A built-in drain port is included to per- mit hydrostatic testing without draining the system. The assembly has a working pressure rating of 175 2. psi (12.1 bar). Cast -in mounting holes are provided for recessed or flush mounting to a wall. For stud mounting, a support bracket is available that is spe- cifically designed for the cast mounting holes. All of the trim variations include brass compo- nents, a cULus Listed 300 psi water pressure gauge, and a 250 psi UL Listed/ ULC Listed Waterflow Detector. This Waterflow Detector comes factory installed with a weatherproof (outside) cover. Trim Descriptions • Basic Trim Residential riser manifold assembly trim shall include a cULus Listed pressure gauge, a drain valve, and dedicated waterflow detector containing two sets of SPDT (Form C) contacts, having an electrical rating of 10A @ 125/250 VAC/2.5 A @ 24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM). • Basic Trim with Pressure Relief Kit Residential riser manifold assembly trim shall include a cULus Listed pressure gauge, a drain valve, and dedicated waterflow detector containing two sets of SPDT (Form C) contacts, having an electrical rating of 10A @ 125/250 VAC/2.5 A @ 24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM).Pressure relief valve kit shall be provided to maintain system pressures below 175 psi (12.1 bar). • Basic Trim with Test and Drain Valve Residential riser manifold assembly trim shall include a cULus Listed pressure gauge, a Test and Drain valve, and a dedicated waterflow detector containing two sets of SPDT (Form C) contacts, having an electrical rating of 10A @ 125/250 VAC/2.5 A @ 24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM). The test orifice size for the Test and Drain assembly shall be** **(Choose one) • 3/8" (10 mm) • 7/16" 01 mm) • 1/2" (15 mm) • Basic Trim with Test and Drain Valve & Pressure Relief Kit Residential riser manifold assembly trim shall include a cULus Listed pressure gauge, a Test and Drain valve, and a dedicated waterflow detector containing two sets of SPDT (Form C) contacts, having an electrical rating of 10A @ 125/250 VAC/2.5 A @ 24 VDC. Triggering flow rate is 4(15) GPM(LPM) to 10(38) GPM(LPM). Pressure Relief Kit shall be provided to maintain system pressures below 175 psi (12,1 bar). Installation: 1. Install the manifold with the flow arrow pointing towards SYSTEM side using threaded connec- tions. 2. Connect a 1" NPT drain line. Ensure the drain Ball Valve is in the CLOSED position. 3. Place the sprinkler system in service. Caution: Automatic sprinkler systems having non -fire protection connection (permitting continual water flow) require dielectric fittings, according to NFPA 13 sect. 4-6, when dissimilar metal piping materials are joined. Note: 2 112" MINIMUM GAP FOR WATER FLOW INDICATOR COVER REMOVAL(TYPICAL ALL MANIFOLDS) -E- STUD SUPPORT BRACKET MOUNT BRACKET FLUSH WITH FACE OF STUD Fig.6 WOOD PANEL PLASTIC SPACERS STUD L--------- ----J fit ��T -� _IJ RECESSED OR FLUSH MOUNTED 3. Fig.7 r Ordering Information: Residential Riser Part Number Code Key 1N 1M 1.5N 1.5M 2N 2M 1 N =1" (25mm) NPT Threaded Ends Assembly 1 M =1" (25mm) Metric Threaded Ends Assembly 1.5N=1-1/2" (40mm) NPT Threaded Ends Assembly 1.51M =1-11Z (40mm) Metric Threaded Ends Assembly 2N = 2" (50mm) NPT Threaded Ends Assembly 2M = 2" (50mm) Metric Threaded Ends Assembly B T38 T716 T12 B = Basic Trim Assembly T12 = Basic Trim Assembly with 1/2" (15mm) Onf. Test and Drain Valve 0 1 2 3 0 = Assembly without Pressure Relief Kit Water Detector - UL & FM Approved 1 = Assembly with Pressure Relief Kit Water Detector - UL & FM Approved 2 = Assembly without Pressure Relief Kit Water Flow Detector - ULC Approved 3 = Assembly with Pressure Relief Kit Water Row Detector - ULC Approved Example #1: 1.5N — B —1 (1-112" (40mm) Residential Riser Assembly with NPT Female Inlet and Outlet Threads, Basic Trim with installed Pressure Relief Kit). Example #2: 2M — T12 — 0 (2" (50mm) Residential Riser Assembly with Metric Female Inlet and Outlet Threads, Basic Trim with Test and Drain Valve having a 112" Diameter Test Orifice.) Also, If Required: Description Part Number Pressure Relief Kit For Basic Trim 98020076 Pressure Relief Kit For Basic Trim with Test and Drain Valve 6501203551 Support Bracket Kit 6899190001 Waterflow Detector RFDTH 96556910 Waterflow Detector ULC RFDTHA 96556914 Paddle Tree - Waterflow Detector 96556911 The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. ® Recycled iabil® (800) 431-1588 Sales Offices Paper m (800) 848-051 Sales Fax (914) 829-2042 Corporate Offices Revision lines indicate updated or new data www.reliablesprinkler.com Internet Address E.G. Printed in USA 08/09 P/N9999970348 Bulletin 006 Rev. K February 2017 Reliable Model RFC Series Residential Sprinklers cULus Listed Flat Cover Plate, Concealed Pendent Sprinkler Product Features cULus Listed as Residential Sprinklers Push -On cover plate installation Low water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. Model RFC30, RFC43, and RFC49 sprinklers have a 1650F (74°C) temperature rated fusible -link operating element. Model RFC58 sprinklers are offered with either a 1650F (74°C) or 212OF (100°C) temperature rated fusible -link op- erating element. Sprinklers with a 1650F (74°C) temperature rating are ordinary temperature classification and should be used with a 1350F (57°C) temperature rated cover plate. Sprinklers with a 212OF (100°C) temperature rating are inter- mediate temperature classification and should be used with a 1650F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC cover plate. Model RFC cover plates may be installed by either pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC43, and RFC49 sprinklers allow 1/2" (13 mm) of cover plate adjustment. Model RFC58 sprinklers allow 3/4" (19 mm) of cover plate adjustment. Model RFC cover plates are available in a variety of finishes as listed in Table H. In addition, Model RFC cover plates may be ordered as either traditional solid cover plates or perforated cover plates. Model RFC30 f Model RFC49 Solid Perforated Model RFC Cover Plate Sprinkler Model Nominal K-Factor 12 „ gpm/psi (1/min/bar i Max. Coverage Area ft x ft (m x m) Sprinkler IdentificationNumber (SIN) RFC30 3.0 (43.2) 14 x 14 (4.3 x 4.3) RA0611 RFC43 4.3(62) 20 x 20 (6.1 x 6.1) RA0612 RFC49 4.9 (70.6) 20 x 20 (6.1 x 6.1) RA0616 RFC58 5.8(84) 20 x 20 (6.1 x 6.1) RA0613 www.reliablesprinkler.com Technical Specifications Cover Plate Finishes Style: Flat Concealed Pendent (See Table H) Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 3.0 (43.2 metric) Sensitivity Max. Working Pressure: 175 psi (12 bar) Fast -response Min. Spacing: 8 ft. (2.4 m) Temperature Rating Material Specifications 165OF (74°C) sprinkler Thermal Sensor. Nickel Alloy Solder Link 135°F (57°C) cover plate Sprinkler Body: Brass Alloy Levers: Bronze Alloy Cover Plate Yoke: Brass Alloy Model RFC cover plate Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrench Towers: Copper Alloy Model FC Pins: Stainless Steel Deflector: Bronze Alloy Listings and Approvals Cup: Steel cULus Listed Model RFC30 Sprinkler Components and Dimensions Threads Body Cup Tower Fusible Link Deflector (retracted) Pin (extended) - Deflector (extended) 1-3/4" (44 mm) +/- 1/4" (6 mm) Nominal face of fitting to ceiling Model RFC Cover Plate 164x j I boa; Bottom View 2-5/16" (58 mm) Dia. 3-5/16" (84 mm) Dia. 3/16" (5 mm) Ceiling Model RFC30 Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure Max. Coverage Area Flow Pressure ft. x ft. gpm psi (m x m) (1/min) (bar) 12 x 12 9 9.0 (3.6 x 3.6) (34) (0.62) 14 x 14 10 11.0 (4.3 x 4.3) (38) (0.76) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table B above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Rev. K �',��'� Page 2 of 7 February 2017 www.reliablesprinkler.com Technical Specifications Cover Plate Finishes Style: Flat Concealed Pendent (See Table H) Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor 4.3 (62 metric) Sensitivity Max. Working Pressure: 175 psi (12 bar) Fast -response Min. Spacing: 8 ft. (2.4 m) Temperature Rating Material Specfcatfons 165°F (74°C) sprinkler Thermal Sensor: Nickel Alloy Solder Link 1350F (57°C) cover plate Sprinkler Body- Brass Alloy Levers: Bronze Alloy Cover Plate Yoke: Brass Alloy Model RFC cover plate Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrench Towers: Copper Alloy Model FC Pins: Stainless Steel Deflector. Bronze Alloy Listings and Approvals Cup: Steel cULus Listed Model RFC43 Sprinkler Components and Dimensions . . 2-5/16"(58 mm) Threads Dia. Body Cup = - 127 Tower 1-3/4" (44 mm) +/- 1/4" (6 mm) Fusible Link Nominal face of fitting to ceiling Deflector (retracted) 3/16"(5mm) Pin (extended) Deflector (extended) V, Model RFC Cover Plate 3-5/16" (84 mm) Dia. Ceiling Model RFC43 Sprinkler Hydraulic Design Criteria .. - Minimum Flow and Residual Pressure Max. Coverage Area Flow Pressure ft. x ft. gpm psi (m x m) (Vmin) (bar) 12 x 12 12 7.8 (3.6 x 3.6) (45) (0.54) 14 x 14 13 9.1 (4.3 x 4.3) (49) (0.63) 16 x 16 13 9.1 (4.9 x 4.9) (49) (0.63) 18 x 18 18 17.5 (5.5 x 5.5) (68) (1.21) 20 x 20 21 23.8 (6.1 x 6.1) (79) (1.64) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table C above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Rev. K Page 3 of 7 February 2017 ellabld www.reliablesprinkler.com Technical Specifications Cover Plate Finishes Style: Flat Concealed Pendent (See Table H) Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor. 4.9 (70.6 metric) Sensitivity Max. Working Pressure: 175 psi (12 bar) Fast -response Min. Spacing: 8 ft. (2.4 m) Temperature Rating Material Specifications 165°F (74°C) sprinkler Thermal Sensor. Nickel Alloy Solder Link 135°F (57°C) cover plate Sprinkler Body: Brass Alloy Levers: Bronze Alloy Cover Plate Yoke: Brass Alloy Model RFC cover plate Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrench Towers: Copper Alloy Model FC Pins: Stainless Steel Deflector: Bronze Alloy Listings and Approvals Cup: Steel cULus Listed � _ l .NWVA, Model RFC49 Sprinkler Components and Dimensions - 2-5116" (58 mm) Threads Dia. Body = _ Cup = _ Tower 1-3/4" (44 mm) +/- 1/4" (6 mm) Fusible Link Nominal face of fitting to ceiling Deflector (retracted) 7 " " 3/16" (5 mm) Pin (extended) Deflector (extended) Model RFC Cover Plate 3-5/16" (84 mm) Dia. Ceiling Model RFC49 Sprinkler Hydraulic Design Criteria • • ' Minimum Flow and Residual Pressure Max. Coverage Area Flow Pressure ft. x ft. gpm psi (m x m) (1/min) (bar) 16 x 16 13 7.0 (4.9 x 4.9) (49.0) (0.48) 18 x 18 17 12.0 (5,5 x 5.5) (64.3) (0,83) 20 x 20 20 16.7 (6.1 x6.1) (75.7) (1.15) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table D above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Rev. K � Page 4 of 7 February 2017 .� Reliable! www.reliablesprinkler.com Technical Specifications Sensitivity Style: Flat Concealed Pendent Fast -response Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor. 5.8 (84 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) Ordinary: Min. Spacing: 8 ft. (2.4 m) 165°F (74°C) sprinkler 135"F (57°C) cover plate Material Specifications Intermediate: Thermal Sensor: Nickel Alloy Solder Link 212°F (100°C) sprinkler Sprinkler Body- Brass Alloy 165OF (74°C) cover plate Levers: Bronze Alloy Yoke: Brass Alloy Cover Plate Sealing Assembly: Nickel Alloy with PTFE Model RFC Cover Plate Load Screw: Bronze Alloy Towers: Copper Alloy Sprinkler Wrench Pins: Stainless Steel Model FC Deflector: Chrome Plated Bronze Alloy Cup: Steel Listings and Approvals cULus Listed Cover Plate Finishes (See Table H) Model RFC58 Sprinkler Components and Dimensions Bottom View 2-5/16" (58 mm) Dia. Threads Body Cup Tower Fusible Link 1-7/8" (48 mm) +/- 3/8" (9 mm) Deflector (retracted) Nominal face of fitting to ceiling Pin (extended) Deflector (extended) Model RFC Cover Plate —� f--- 3-5/16" (84 mm) Dia. 3/16" (5 mm) Ceiling Model RFC58 Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure 7 Max. Coverage Area(2) Flow Pressure ft. x ft. gpm psi (m x m) (1/min) (bar) 16 x 16 16 7.6 (4.9 x 4.9) (60.6) (0.53) 18 x 18 18 9.6 (5.5 x 5.5) (68.1) (0.66) 20 x 20 20 11.9 (6.1 x 6.1) (75.7) (0.82) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area,listed. Bulletin 006 Rev. K e, aV February 2017 www.reliablesprinkler.com Cover Plate FinishesM Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(3) Custom Color Paint(2) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Custom color paint is semi -gloss, unless specified otherwise. 3. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the backside. Cover plates are not listed or approved as corrosion resistant. Stainless steel clad cover plates are not available perforated. Installation Dimensions Recommended Min. to Min. to Max. Cover Cover Plate Hole Diameter Cover Plate Max. Face Dropped Deflector Cover Plate Sprinkler Plate Diameter in Ceiling Adjustment of Fitting to Distance below Temperature Model Model inch inch inch Ceiling) Ceiling Rating (mm) (mm) (mm) inch inch (mm) (mm) RFC30 RFC43 RFC 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 135OF RFC49 (84) (67) (13) (38 to 51) (13 to 25) (57°C) 1350F(2) RFC58 RFC 3-5/16 2-5/8 3/4 1-1/2 to 2-1/4 1/4 to 1 (57°C) (84) (67) (19) (38 to 57) (6 to 25) or 165°F(3) (74°C) Notes: 1. Face of fitting to ceiling dimensions are based on a nominal thread makeup. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2" x 1/2" brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing sprinklers. 2. For use with 165OF (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100OF (38°C). 3. For use with 212°F (100°C) temperature rated sprinklers with the Maximum Ceiling Temperature does not exceed 150°F (66°C). Installation Model RFC series sprinklers are intended to be installed in ac- cordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Mod- el RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a protective cap that should remain on the sprinkler until installed. The protective cap should be replaced following installation of the sprinkler and permanently removed only when the cover plate is installed and the sprinkler system is placed in service following construction. Model RFC series sprinklers are installed with the Model FC wrench. The use of any other wrench to installed Model RFC se- ries sprinklers is not permitted and may damage the sprinkler. Temporarily remove the protective cap during installation of the sprinkler. Insert the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model FC wrench is designed to be turned with a standard 1/2" square drive. Tighten the sprin- kler into the fitting after applying a PTFE based thread sealant to the sprinkler's threads. Recommended installation torque is 8 to 18 ft/lb (11 to 24 N/m). Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or im- pairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 13D. The sprinklers are concealed pen- dent residential sprinklers. Model RFC 30, RFC43, and RFC49 sprinklers are available in ordinary temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100OF (380C). Model RFC58 sprinklers are available in either ordinary or in- termediate temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100OF (38°C) or 150OF (660C), respectively. Bulletin 006 Rev. K February 2017 Page 6 of 7 www.reliablesprinkler.com Maintenance Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non -oper- ation. Listings and Approvals Listed by Underwriters Laboratories, Inc. and UL Certified for Canada (cULus) UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents Model RFC30, RFC43, RFC49, and RFC58 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Model RFC30 and RFC43 sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler • Model (RFC30, RFC43, RFC49, RFC58) • Temperature Rating Cover Plate • Model RFC • Temperature Rating • Finish (See Table H) Sprinkler Wrench • Model FC v z V O N Bulletin 006 Rev. K Page 7 of 7 February 2017 �� �V�� www.reliablesprinkler.com Bulletin 157 Rev. I ,a I @ R I be Features 1. The Model F3QR sprinkler utilizes Belleville Spring Closure Technology. Reliable is the first in the industry to produce a Quick Response Dry Concealed sprin- kler utilizing this technology. 2. Styles available • Pendent • Recessed FP Pendent • Recessed F1 Pendent • Concealed • Horizontal Sidewall • Recessed FP Horizontal Sidewall • Recessed F1 Horizontal Sidewall 3. 1 Y2" (38mm) escutcheon adjustment on pendent sprinkler. 4. 1/2" (13mm) escutcheon adjustment on recessed sprin- kler with push -on/ thread -off FP Model Escutcheon ring. 5. 3/8" (9.5mm) cover plate adjustment on concealed sprinkler with push -on/ thread -off CCP Cover Plate. 6. 3/4" (19mm) escutcheon adjustment on recessed sprinkler with F1 Escutcheon. 7. Attractive appearance. Employs 3mm frangible glass bulb and galvanized nipple. 8. Lengths available to accommodate installation di- mensions from 2" - to - 48" (51 mm - to - 1219mm), in '/4" (6mm) increments. See specific styles for correct "A" dimension range. 9. Available in a variety of plated and painted finishes. 10.Polyester Coated Corrosion Resistant Sprinklers. US Patent Numbers 5,775,431 and 5,967,240. Other US Patents pending. Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Style Response Sprinkler System Type Hazard Pendent Recessed Pendent Wet Pipe Light Recessed F1 Pendent Quick Dry Pipe Ordinary CCP Concealed All Preaction R5714 Horizontal Sidewall Wet Pipe Recessed Horizontal Sidewall Quick Dry Pipe Light (R5734) All Preaction 2. Certified by FM Approvals Style Response Sprinkler System Type Hazard Pendent Wet Pipe Light Ordinary, Recessed F1 Pendent Quick Dry Pipe Groups (R5714) All Preaction 1&2 Horizontal Sidewall Wet Pipe Recessed F1 Horizontal Sidewall Quick Dry Pipe Light (R5734) All Preaction 3. NYC MEA 258-93-E Model F3QR Quick Response Dry Sprinklers Pendent (See Fig. 1) Recessed FP Pendent (See Fig. 3) Recessed F1 Pendent (See Fig. 5) Recessed FP Horizontal Sidewall (See Fig. 8) Pendent / HB (See Fig. 2) Concealed (See Fig. 4) Horizontal Sidewall (See Fig. 6) Horizontal Sidewall / HB (See Fig. 7) Recessed F1 Horizontal Sidewall (See Fig. 9) Q CD Z The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F30R Dry Pendent Sprinkler "A" Dim. 1 2" to 48" (51mm to 1219mm) in 1/4" (6mm) increments Finishes(") Sprinkler Escutcheon Bronze Brass (3) Chrome Plated Chrome Plated White Polvester (2) White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. tat Not available for HB escutcheons. �- u z� System lee 1" NPT 2 1/8" Die. [54^0mm] "A" Dimension Hole i Ceil;ng Adjustment Range —1/4" [-6.4mm] 1 43/64" Die. +1 1/4" [+31.8mm] [42.5mm] 1 1/2" [38.1mm] Totol Adjustment Sprinkler Con Ceiling 1 1/4" [31.8mm] 1/4" [6.4mm] Escutcheon Escutcheon Ceiling ei a Adjustment Nominal PosilioA t 5/8. of Escutcheon [41.3mm] 1/4" [6.4mm] Protrusion 3" Dio. [76.2mm] NEW157FGOI Fig. 1 Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal position. Escutcheon adjustment provides '/4" (-6mm) to +11/4" (+32mm) "A" dimension adjustment range. Sprinkler Guard: Model C-2 Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 Model F3QR Dry Recessed FP Pendent S rinkler "A" Dim. 31/2" to 48" 89mm to 1219mm in'/4" 6mm increments Finishes`'' Sprinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated White Polyester (2) White (1) Other finishes and colors are available on special order.. Consult factory for details. Cup remainds unfinished. Only the escutcheon will contain desired finish. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. Standard Temperature Ratings - Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135°F (57°C) 100°F (380C) Orange Ordinary 155°F (680C) 100°F (38°C) Red Intermediate (1) 1750F (79°C) 150OF (66°C) Yellow Intermediate 200OF (93°C) 150°F (66°C) Green High (1) 2860E 141°C 225°F 107°C Blue Sprinkler cup and FP Escutcheon fabricated of steel and recommended for interior applications. t1] Listed and Certified only by cULus. Model F30R Dry Pendent w/HB Escutcheon "A" Dim. 3'/z" to 48" 89mm to 1219mm in 1/4" 6mm increments Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Tern . Ordinary 135°F (57°C) 100-F (38°C) Orange Ordinary 155°F (680C) 100-F (38°C) Red Intermediate (1) 175OF (79°C) 150OF (660C) Yellow Intermediate 200°F (930C) 150°F (660C) Green High (1) 2860E 1410C 2250E 107°C Blue Sprinkler can and escutcheon fabricated of brass for better weather resistance in exterior applications. (1) Listed and Certified only by cULus. F==[��__= 7 F system Tee "A" Dimension 2 1/2" [63.5mm] 1' NPT Adlu:tmmf Range p;a. Hole Ceiling —1/2" [-12.7mm] 3 1/2" [88.9mm] +1/2" [+12.7mm] Escutheon Dio. Estulheon Adj. Ceiling 1" [25.4] Escutcheon Total Adj. 1/2' [12.7mm] Estulheon Atlj. s Sprinkler Can Nominal Position of Escutcheon 1-1/4" [31.75mm] 1 5/8" Nominal Protrusion [41.3mm] 2 13/64" [55.88mm] NEW157lG02 Die. Fig. 2 Note: The sprinkler can protrudes 11/4" when escutcheon is in nomi- nal position. Escutcheon adjustment provides '/2" (-12.7mm) to +112" (+12.7mm) "A" dimension adjustment range. E- u System Tee 1" NPT 2 1/2" Die. [63.50mm] "A" Dimension Hole in Ceiling Adjustment Ronge 31/4" 2 19/64" Die. [t6.35mm] [58.34mm] Nominol Position Sprinkler of Escutcheon Cup Assembly Ceiling �IE�fl:�Ceiling Escutcheon 1/4" [6.35mm] Escutcheon Adjustment L 1/4" [6.35mm] 3 7/32" Did. Escutcheon Adjustment [81.76mm] 1/2" [12.7mm] Totol Adjustment NEW157FGOJ Fig. 3 Note: Do not install the Model F3QR Dry Recessed FP Pendent Sprin- kler in ceilings which have positive pressure in space above. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 2. Model F30R Dry Pendent Concealed Sprinkler "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" 6mm increments CCP Cover Plate "' Finishes "' Standard Finishes Special Application Finishes Chrome Plated Bright Brass Plated White Black Plated Black Paint Off White Satin Chrome (1) Utilizes the 1/2" cover plate with 3/8" total adjustment. (2) Other finishes and colors are available on special order. Consult factory for details. Standard Temperature Ratings Sprinkler Cover Plate Max. Classification Temperature Temp. Rating Ambient Rating Temp. Ordinary 135-F (57aC) 135-F (57aC) 100-F (38aC) Ordinary 155-F (68aC) 135-F (57aC) 100-F (38aC) Intermediate (1) 175oF (79aC) 165oF (740C) 150oF (660C) Intermediate 200-F (93aC) 165-F (74aC) 150-F (66aC) High (1) 286aF(141aC) I 165aF (74aC) 150OF (66aC) Sprinkler cup fabricated of steel and CCP Cover Plate fabricated of brass and recommended for interior applications. (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 Model F30R Dry Recessed F1 Pendent Sprinkler "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" 6mm increments �inichnc t/1 ' Sprinkler Escutcheon JCollar Chrome Plated White Pol ester (2) Chrome Plated White JChrome Plated White t11 Other finishes and colors are available on special order. Consult factory for details. t2j cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135-F (57aC) 100-F (38aC) Orange Ordinary 155-F (68aC) 100-F (38aC) Red Intermediate (1) 175aF (79aC) 150aF ,(66aC) Yellow Intermediate 200-F (93aC) 150oF (66aC) Green High (1) 286oF (1410C) I 225aF (107aC) I Blue (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 System Tee 1" NPT 2 1/2" Dia. [6.35mm] "A" Dimension Hole in Ceiling Adjustment Range 3 3/16^ 2 19/64" Dia. [34.76mm] [58.34mm] Nominal Position of Coverplate Sprinkler Cup Assembly Coverplate Ceiling Assembly Ceiling Coverplate Adjustment 3/16" [4.76mm] Di Coverplote Adjustment 3 5/16" Dia . [84.13m ml 3/8" [9.53mm] Total Adjustment NEW157FG04 Fig. 4 Note: Do not install the Model F3QR Dry Concealed Pendent Sprinkler in ceilings which have positive pressure in the space above. 2 1/2" Dia. [63.50mm] Hole in Ceiling "A" Dimension Adjustment Range ± 1 /4" [f 6.35mm] Nominal Position of Escutcheon Ceiling 1/4" [6.35] Escutcheon Adjustment 1/4" [6.35] Escutcheon Adjustment 1/2" [12.7mm] Adjustment u System Tee 1" NPT 1 15/16" [49.2mm] 15/16" [23.8mm Sprinkler Cup Assembly 1 /8•. Ceiling Escutcheon 2 27/32" NEW157FG05 [72.2mm] Fig. 5 3. Model F30R Dry Horizontal Sidewall Sprinkler Model F30R Dry HSW w/HB Escutcheon "A" Dim. 1 2" to 48" 51mm to 1219mm in 1/4" 6mm increments "A" Dim. ,'to 48" 89mm to 1219mm in 1/4" 6mm increments Finishes(" Sprinkler Escutcheon Bronze Brass (3) Chrome Plated Chrome Plated White Polyester (2) White (') Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) Not available for HB escutcheons. 1 1/2" [38.10mm] Total Adjustment Ceiling o 3 4" [101.60mm] Mi 1 1/4" [31.75mm] 12" [304.80mm] M Escutcheon Adjustment System Tee Escutcheon Adjustment 1" NPT 2 3/32" [53.18mm] 3" [76.20mm] 2 1/8" Dio. o [53.98mm] 3 Hole in Wall 1/4" [6.35mm] Sprinkler Can Protrusion "A" Dimension Adjustment KN.minol Position Range — 1/4" [-6.35mm] of Escutcheon NEW137FG06 + 1 1/4 [+31.75mm] Fig. 6 Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal position. Escutcheon adjustment provides '/4" (-6mm) to +1'/4" (+32mm) "A" dimension adjustment range. (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model F3 Sprinkler Wrench prinkler Identification Number (SIN): R5734 Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135-F (570C) 100-F (38aC) Orange Ordinary 155-F (68aC) 100OF (381C) Red Intermediate (') 175oF (79aC) 150aF (660C) Yellow Intermediate 200-F (930C) 150-F (66aC) Green High 286aF 141-C 225aF 107*C Blue Sprinkler can and escutcheon fabricated of brass for better weather resistance in exterior applications. 1" [25.4mm] Total Adjustment Ceiling T 1/2" [12.7mm] Escutcheon Adjustment 4" [101.60mm] Min. 12" [304.80mm] Mc.. Escutcheon Adjustment 2 3/32" System Tee 3 [53.18mm] r 1' NPT / 2-13/64" 3-1/2" [55.Bemm] [889mm] Escutcheon Dio. 2 1/2" Dio. [63.5"1 Hole in Wall L"A" 1-1/4" [31.75mm] Nominal Protrusion Sprinkler Can Dimension Escutcheon Adjustment Nominal Position Nnrrsmor Range + 1/2" [+12.7mm] of Escutcheon - 1/2" [-12.7mm] Fig. 7 Note: The sprinkler can protrudes 11/4" when escutcheon is in nomi- nal position. Escutcheon adjustment provides '/2" (-12.7mm) to +'h" (+12.7mm) "A" dimension adjustment range. Model F30R Dry Recessed FP Horizontal Sidewall Sprinkler "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" 6mm increments Finish (" Sprinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated White Polyester (2) White (') Other finishes and colors are available on special order. Consult factory for details. Cup remainds unfinished. "See page 2" (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. Standard Temperature Ratings Classification Sprinkler Tem- erature Rating Max. Ambient Temp. Bulb Color Ordinary 135-F (57aC) 100-F (380C) Orange Ordinary 155-F (68aC) 100-F (380C) Red Intermediate (') 175aF (79aC) 150aF (660C) Yellow Intermediate 200oF (93aC) 150oF (66aC) Green High (') 286aF (141-C) 225aF 107*C Blue (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 Esc Wcheon - Cup 1" NPT 2 1/2' Dio. [63.5mm] Hole in Wall 2 19/64" Dtc. [58.3mm] "A" Dimension Atljustment Range N£W137F 8 * 1 /4" [i6.35mm] 1 ,3/32" [35.7mm] 4' [101.6mm]Mln. ,2" [304.Bmm]Ma..' 3 7/32' Dio. Nominol Position Sr " Escutcheon Ad" [12.7mm] Escutcheon Adjustment t /4" [6.35] Escutcheon Adjustment Y: • FOR FACTORY MUTUAL (FM) • 4" - 6" FOR UNDERWRITERS LABORATORIES (UL) Fig. 8 Notes: Do not install the Model F3QR Dry Recessed FP Horizontal Sidewall Sprinkler in walls which have positive pressure in their side space. • Listed by cULus for Quick Response. Approved by FM for Standard Response. • Recessed Horizontal sidewall sprinklers are listed with cULus for installation of min. 4" (100mm) - to - max. 6" (150mm) below ceiling and approved by FM for installation of min. 4" (100mm) - to - max. 12" (300mm) below ceiling. 4 Model F30R Dry Recessed F1 Horizontal Sidewall Sprinkler "A" Dim. 31/2" to 48" (89mm to 1219mm)in Y4" 6mm increments Finishes " ) S rinkler Escutcheon Collar Chrome Plated White Polyester (2) Chrome Plated White Chrome Plated White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135-F (57aC) 100-F (38aC) Orange Ordinary 155-F (68aC) 100-F (38aC) Red Intermediate (1) 175aF (790C) 150OF (66aC) Yellow Intermediate 200-F (93aC) 150-F (66aC) Green High(') 2860F (141aC) 225aF (107aC) I Blue (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 Technical Data: Orifice Size: 1/2" (15mm) Thread Size: 1" NPT per ANSI B2.1 Working Pressure: 175 psi (12 bar) Nominal K Factor - US / (Metric): 5.6 / (80) Product Description Reliable Model F3QR DrySprinklersarequick response sprinklers utilizing a durable 3mm frangible glass bulb. This quick response enables these sprinklers to apply water to a fire much sooner than standard response sprinklers of the similar temperature rating. Model F30R Dry Sprinklers are intended for use in dry and preac- ton systems and in areas subjected to freezing temperatures, such as freezers and unheated portions inside and outside buildings. Environments wherein dry sprinklers are employed can be cor- rosive. For this reason, Model F3 Sprinklers have a special wax fillet placed in the gap between the cup that supports the bulb and the wrenching boss. This wax will not interfere with the operation of the sprinkler, and it prevents contaminants from entering the internal portion of the drop nipple. The wax must not be removed. Operation The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. When the temperature increases sufficiently, due to a fire, the bulb shatters allowing operating parts to clear the waterway. This enables the inlet seal to release air or water and subsequently, cause water flow over the deflector in a uniform spray pattern, controlling or extinguishing the fire. Ceitin9 r X Escutcheon [3.2mm] System Tee Sprinkler Cup 3 ' 4" [101.6mm]Min., 12" [304.Bmm]Moz. /-- 1" NPTAssembl Y_�_ j 3 [72.2mm] I�2 1/2" Dia. [63.Smm] Hole in Wall 131 Nominal Position • 1 15/16" of Escutcheon [49.2mm] Escutcheon Adjustment "A" Dimension 1/2" [12.7mm] NEW157FG09 Adjustment Range Adjustment 31/4" [36.35mm] 1/4" [6.35] Esoutohenn Adi—imont #'. FOR FACTORY MUTUAL (FM) • 4" — 6" FOR UNDERWRITERS LABORATORIES (UL) Listed by cULus for Quick Response. Approved by FM for Standard Response. Recessed Horizontal sidewall sprinklers are listed with cULus for installation of min. 4" (100mm) - to - max. 6" (150mm) below ceiling and approved by FM for installation of min. 4" (100mm) - to - max. 12" (300mm) below ceiling. Ordering Information Specify: 1. Sprinkler Type (select one): (a) Model F3QR Dry Pendent (b) Model F3QR Dry Pendent/HB (c) Model F3QR Dry Recessed FP Pendent (d) Model F3QR Dry Recessed F1 Pendent (e) Model F3QR Dry Concealed Pendent (f) Model F30R Dry Horizontal Sidewall (g) Model F3QR Dry Horizontal Sidewall/HB (h) Model F3QR Dry Recessed FP Horizontal Sidewall (i) Model F3QR Dry Recessed F1 Horizontal Sidewall 2. Sprinkler Temperature Rating. 3. Sprinkler Finish. 4. Escutcheon type (F1 or FP). 5. Cover Plate/Escutcheon Finish. 6. Length: "A" Dimension (face of tee to face of ceiling or wall) in (6mm) increments. 7. Model F3QR Dry Pendent (a) is available without sprinkler can and escutcheon. Note: 1. The "A" dimension is based on a nominally gauged pipe thread "make-up" of 0.600" (15mm) per ANSI B2.1 [71/2 threads approximately]. 2. All platings and paintings are decorative and intend- ed for interior use. 5. General Installation Instructions Model F3QR dry sprinklers must be installed only in stan- dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) pipe tees in the horizontal position, even at branch line ends. They should not be installed into elbows or pipe couplings located on drop nipples to the sprinklers. For these and other fittings including CPVC", the dry sprinkler should be installed into a fitting to allow protrusion into the fitting in ac- cordance with the diagrams. The "A" dimension of the dry sprinkler, which extends into the freezers or a freezing zone from wet pipe systems, should be selected to provide, as a minimum, the specified lengths in inches shown in Fig. 10. Caution: Do not install Model F3QR Dry sprinklers into CPVC adapter fittings or tees that have an internal obstruction. This will damage the sprinkler and /or the fitting. Refer to Fig. 11. During installation, the following steps must be followed 1. Cut the specified size hole (see illustrations) for the sprin- kler in the ceiling or wall directly in line with the tee. 2. Apply pipe joint compound to the 1" (25mm) pipe threads and install sprinkler using the Model F3 or XLO2 Sprinkler Wrench as specified. 3. Install the Model FP push -on / thread -off escutcheon or CCP cover plate if required. Note: Installation of the Model F3QR Sprinklers is not rec- ommended in copper pipe systems, as this may reduce the life expectancy of the sprinklers. Model F30R Concealed and Recessed In- stallation Instructions • The Model XLO2 wrench (Fig. 12) is designed to lo- cate on the wrenching pads of the recessed sprin- kler while centering in the cup. A standard 1/2" drive ratchet may be used to drive this wrench. Fig. 13 and Fig. 14 show sequentially the insertion of the wrench. First the wrench, with its jaws above the sprinkler de- flector, is moved laterally until centered with the cup. Then raise the wrench inside of the cup until its jaws engage the sprinkler's square wrenching pads (Fig. 14). To remove the wrench, follow this procedure in reverse order. Care should be taken to avoid striking the deflector, with the wrench. • Model F3 Wrench (Fig. 15) is used for installation of Pendent and Horizontal Sidewall sprinklers. • Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SER- VICE FOR FIRE PROTECTION. Removal of the pro- tectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PRO- TECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Maintenance The Model F3QR Quick Response Dry Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not remove the factory applied thermally sensitive wax fillet between the bulb sup- porting cup and the wrenching boss. Do not replace this wax with a substitute substance. An Alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gently vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper opera- tion or non -operation. Caution: Use specified by RASCO wrenches only, which are designed to engage sprinkler's wrenching pad. (Fig. 15, page 9) 0 RECOMMENDED EXPOSED MINIMUM BARREL LENGTH BASED ON AMBIENT TEMPERATURE IN THE PROTECTED AREA (STANDARD DRY PENDENT SPRINKLER SHOWN) INSTALL. 1 NCH NPT THREADED END OF DRY PENDENT SPRINKLER WET PIPE NTO THE 1 NCH NPT SIDE OUTLET A MALLEABLE IRON TEE FI1I C PER ANSI B 18.3 CLASS 150) OR CAST IRON TEE FITTING PER ANSI 1&4 (CLASS 125) ONLY. - AjOF -DISCHRIM END IF HUMIDITY AND TEMPERATURE DIFFERENTIAL CAUSES CONDENSATION ON THE EXPOSED, DRY WTTH MSUlAT FOAM INSUSIMTING TAPE OR ECI MAENT. i MDR(FATED AREA SEAL THE CLEARANCE SPACE EXPOSED AROUND THE SPRINKLM TD AVOID BARREL I LEAKAGE OF AIR INTO THE PROTECTED LENGTH 1 AREA AND CONSEQUENT FORMATION OF CONDENSATE AROUND THE FRAME, WHICH COULD V44M OPERATION OR CAUSE 1 PREMATURE OPERATION. SEE BELOW FOR RECD/EIRIEED METHODS. ,A, CLEARANCE DIMENSION HOLE 1 • THE PROTECTED AREA REFERS To THE AREA BELOW THE CEILING. 1 THE AMBIENT TEMPERATURE S THE TEMPERATURE AT THE DISCHARGE END OF THE SPRINKLER, FOR PROTECTED AREA TEMPERATURES THAT OCCUR BETWEEN THE VALUES 1 LISTED. USE THE NEXT COOLER TEMPERATURE. ••THE MN. FMOUIRED BARREL LENGTH S NOT THE SAME AS THE A• DIAENSION. CEILING ESCUTCHEON NOTE: EXPOSED MIND M BARREL LENG M ARE INCLUSIVE UP TO 30MPH WAND VELOCITIES N THE PROTECTED AREA (PRROIYCTED AREA) 3' DIA. *RECOMMENDED EXPOSED MINIMUM BARREL LENGTHS ALSO APPLY TO HORIZONTAL SIDEWALL DRY SPRINKLERS* RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS (STANDARD DRY PENDENT SPRINKLER SHOWN) WET PIPE WET PIPE t0FAAT00 MINIMUM ERPK'� AREA OF -ATM AREA mDamu 1 BARREL R LENGTH D ASSEE ABOVE) OO FLASHING#40039 (RECOMMENDED) NSDE FACE EwDso 1 BARREL I //// --SEAT LENGTH �D 1 CLEARANCE HOLE 1 1 1 i 1 INSUATED FREEZER I OR COOLER STRUCRAiE OR E TERKR FRAMING 1 1 1 1 (PROTECTED AREA) DRY SPRINKLER OMOTECTED AREA DRY SPRINKLER N COLD AREA N COLD AREA NE 157FO10 A►BIEIT TEMPERATURE OF PROIEC'IED AREM AT THE OFSP EWOBED BARIiF1. AMBIDR TEMPERATURE 40'F 4'C 50'F 10c eaF tsc EXPOSED MINBRR/ BARREL LERGnw Fig. 10 7. *CAUTION* DO NOT INSTALL MODEL F3, MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLERS INTO CPVC ADAPTER FITTINGS OR TEES THAT HAVE AN INTERNAL OBSTRUCTION. THIS WILL DAMAGE THE SPRINKLER AND/OR THE FITTING. CPVC ADAPTER FITTINGS AND TEES WITH INTERNAL OBSTRUCTIONS ARE ALSO COMMONLY FOUND DURING THE RETROFITTING PROCESS OF RELIABLE'S OLDER MODEL G3 DRY SPRINKLERS. INTERNAL NO OBSTRUCTION INTERNAL OBSTRUCTION FEMALE FEMALE i PIPE PIPE THREAD THREAD INCORRECT CORRECT CPVC ADAPTER CPVC ADAPTER FITTING OR TEE FITTING OR TEE l 1 1 SHORTER LONGER INLET INLET MALE MALE i PIPE PIPE THREAD THREAD MODEL F3-PL. MODEL F3OR-PL OR STANDARD MODEL DH56 HSW-PL MODEL F3. DRY SPRINKLER MODEL F30R OR MODEL DH56 HSW DRY SPRINKLER BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION 016fg08A Fig. 11 A Fig. 12 - XL02 Wrench Fig. 13 - XL02 Wrench Fig. 14 - XL02 Wrench 91 0 Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured b The Reliable Automatic Sprinkler Co., Inc. ® Recycled 0 (800) 431-1588 Sales Offices Paper iab 10 (914) 848-2051 Sales Fax (800) 8-0Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 12/12 PM 9999970175