Bldg Comments 1 CG Eng.pdfTO: Chevy Chase, PE FROM: Ann Bullis, Asst. Building Official RE: Plan Check # 2008-0078 Project: Tenant Improvement CG Engineering Project Address: 250 4th Avenue South, Suite 101 During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Provide written responses to each comment. Please resubmit to Theresa Umbaugh, Senior Permit Coordinator. 1. Vertical grab bar required at each toilet (see attached for location and dimensions). Note requirements and location on floor plans. 2. Provide dimensioned details on the plans for the proposed accessible showers (see attached pages from accessible code), including size, seat requirements, grab bar, shower controls, etc. If manufacturer's information for the shower shows all requirements, this can be stapled to the plans. Blocking will be required for the seat and grab bars at the framing inspection. 3. Call out existing cfln of restroom exhaust fans. If fans are not provided one is required in each restroom (50 cfm min). 4. Provide detail of the wall bracing to floor -ceiling structure above (revise detail 4/A-1). 5. Return air is required for each room (only supply ducts are shown on the plans). If a separate AC unit is proposed for server room, please show on plans and provide manufacturer's information for the unit. 6. If a reception counter/desk is installed a portion is required to be accessible (i.e., counter surface 36" max above floor, 36" wide surface min. for side approach, 30" wide minimum for front approach) City of Edmonds o� Ego V; ted PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: February 22, 2008 TO: Chevy Chase, PE FROM: Ann Bullis, Asst. Building Official RE: Plan Check # 2008-0078 Project: Tenant Improvement CG Engineering Project Address: 250 4th Avenue South, Suite 101 During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Provide written responses to each comment. Please resubmit to Theresa Umbaugh, Senior Permit Coordinator. 1. Vertical grab bar required at each toilet (see attached for location and dimensions). Note requirements and location on floor plans. 2. Provide dimensioned details on the plans for the proposed accessible showers (see attached pages from accessible code), including size, seat requirements, grab bar, shower controls, etc. If manufacturer's information for the shower shows all requirements, this can be stapled to the plans. Blocking will be required for the seat and grab bars at the framing inspection. 3. Call out existing cfln of restroom exhaust fans. If fans are not provided one is required in each restroom (50 cfm min). 4. Provide detail of the wall bracing to floor -ceiling structure above (revise detail 4/A-1). 5. Return air is required for each room (only supply ducts are shown on the plans). If a separate AC unit is proposed for server room, please show on plans and provide manufacturer's information for the unit. 6. If a reception counter/desk is installed a portion is required to be accessible (i.e., counter surface 36" max above floor, 36" wide surface min. for side approach, 30" wide minimum for front approach) Chapter.6. Plumbing Elements and Facilities 2. In a Type B unit, when a side wall is not available for a 42 -inch (1065 mm) grab bar, the sidewall grab bar shall be per- mitted to be 18 inches (455 mm) mini- mum in length, located 12 inches (305 mm) maximum from the rear wall and extending 30 inches (760 mm) mini- mum from the rear wall. 39-41 990-1040 54 min E LO 12 max 1370 � co 305 co 42 min co Itco 1065 Section 609.4 \ It \(0 � o co rn co Itco Fig. 604.5.1 Side Wall Grab Bar for Water Closet 604.5.2 Rear Wall Grab Bars. The rear wall grab bar shall be 36 inches (915 mm) minimum in length, and extend from the centerline of the water closet 12 inches (305 mm) minimum on the side closest to the wall, and 24 inches (610 mm) minimum on the transfer side. EXCEPTIONS: 1. The rear grab bar shall be permitted to be 24 inches (610 mm) minimum in length, centered on the water closet, where wall space does not permit a grab bar 36 inches (915 mm) minimum in length due to the location of a recessed fixture adjacent to the water closet. 2. In a Type A or Type B unit, the rear grab bar shall be permitted to be 24 inches (610 mm) minimum in length, centered on the water closet, where wall space does not permit a grab bar 36 inches (915 mm) minimum in length. 3. Where an administrative authority re- quires flush controls for flush valves to be located in a position that conflicts with the location of the rear grab bar, that grab bar shall be permitted to be split or shifted to the open side of the toi- let area. 48 ICCIANSI All 7.1-2003 36 min 915 12 min 24 min 305 610 � q 1 to 0) M I I o cri c U � 1 71 Fig. 604.5.2 Rear Wall Grab Bar for Water Closet 604.5.3 Swing -up Grab Bars. Where swing -up grab bars are installed, a clearance of 18 inches (455 mm) minimum from the centerline of the water closet to any side wall or obstruction shall be provided. A swing -up grab bar shall be installed with the centerline of the grab bar 153/4 inches (400 mm) from the centerline of the wa- ter closet. Swing -up grab bars shall be 28 inch- es (710 mm) minimum in length, measured from the wall to the end of the horizontal portion of the grab bar. 153/4 400 I c 04 ~ 18 min 18 min 455 455 Fig. 604.5.3 Swing -up Grab Bar for Water Closet 604.6 Flush Controls. Flush controls shall be hand operated or automatic.. Hand operated flush con- trols shall comply with Section 309. Flush controls shall. be located on the open side of the water closet. ICC/ANSI A117.1-2003 608.2 Size and Clearances. 608.2.1 Transfer -Type Shower Compart- ments. Transfer -type shower compartments shall have a clear inside dimension of 36 inches (915 mm) in width and 36 inches (915 mm) in depth, measured at the center point of opposing sides. An entry 36 inches (915 mm) minimum in width shall be provided. A clearance of 48 inch- es (1220 mm) minimum in length measured perpendicular from the control wall, and 36 inches (915 mm) minimum in depth shall be pro- vided adjacent to the open face of the compart- ment. 36 min 915 back wall 10 wall A+— F �. I� l� wall control 0 48 min 1220 Note: inside finished dimensions measured at the center points of opposing sides Fig. 608.2.1 Transfer -Type Shower Compartment Size and Clearance 608.2.2 Standard Roll -in -Type Shower Compartments. Standard roll -in -type shower compartments shall have a clear inside dimen- sion of 60 inches (1525 mm) minimum in width and 30 inches (760 mm) minimum in depth, measured at the center point of opposing sides. An entry 60 inches (1525 mm) minimum in width shall be provided. A clearance of 60 inches (1525 mm) minimum in length adjacent to the 60 -inch (1525 mm) width of the open face of the shower compartment, and 30 inches (760 mm) minimum in depth, shall be provided. A lavatory coynmplying with Section 606 shall be per- mitted at the end of the clearance opposite the shower compartment side where shower con- trols are positioned. Where shower controls are located on the back wall and no seat is pro - Chapter 6. Plumbing Elements and Facilities vided, the lavatory shall be permitted at either end of the clearance. back wall side side wall wall c � a � ch I i � I � 1 60 min 1525 Note: inside finished dimensions measured at the center points of opposing sides Fig. 608.2.2 Standard Roll -in -Type Shower Compartment Size and Clearance 608.2.3 Alternate Rall -in -Type Shower Compartments. Alternate roll -in shower compartments shall have a clear inside dimen- sion of 60 inches (1525 mm) minimum in width, and 36 inches (915 mm) in depth, measured at the center point of opposing sides. An entry 36 inches (915) mm) minimum in width shall be provided at one end of the 60 -inch (1525 mm) Width of the compartment. A seat wall, 24 inch- es (610 mm) minimum and 36 inches (915 mm) maximum in length, shall be provided on the entry side of the compartment. 608.3 Grab Bars. Grab bars shall comply with Sec- tion 609 and shall be provided in accordance with Section 608.3. Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the floor. EXCEPTIONS: 1. Grab bars are not required to be installed in a shower facility for a single occupant, ac- cessed only through a private office and not for common use or public use, provided rein- forcement has been installed in walls and lo- cated so as to permit the installation of grab bars complying with Section 608.3. 2. In Type A units, grab bars are not required to be installed where reinforcement complying with Section 1003.11.9 is installed for the fu- ture installation of grab Bars. 57 Chapter 6. Plumbing Elements and Facilities q_- — end wal I seat wall 24-36 36 min 610-915 915 60 min 1525 LO V) side wall Note: inside finished dimensions measured at the center points of opposing sides Fig. 608.2.3 Alternate Roll -in -Type Shower Compartment Size and Clearance 608.3.1 Transfer -Type Showers. Grab bars for transfer type showers shall comply with Section 608.3.1. 9 F 58 608.3.1.1 Horizontal Grab Bars. Horizon- tal grab bars shall be provided across the control wall and on the back wall to a point 18 inches (455 mm) from the control wall. 608.3.1.2 Vertical Grab Bar. A vertical grab bar 18 inches (455 mm) minimum in length shall be provided on the control end wall 3 inches (75 mm) minimum to 6 inches (150 mm) maximum above the horizontal grab bar, and 4 inches (100 mm) maximum inward from the front edge of the shower. 608.3.1.3 Grab Bar Configuration. Grab bars complying with Sections 608.3.1.1 and 608.3.1.2 shall be permitted to be sep- 6 max 6 max (a) Without Seat ICC/ANSI All 7.1-2003 arate bars, a single piece bar, or combina- tion thereof. X18 back wall r `'tea seat control wall I I wall _5Max 102 Fig. 608.3.1 Grab Bars in Transfer -Type Showers 608.3.2 Standard Rall -In -Type Showers. In standard roll -in type showers, grab bars shall be provided on three walls of showers without seats. Where a seat is provided in a standard roll -in type shower, grab bars shall be provided on the back wall and on the wall opposite the seat. Grab bars shall not be provided above the seat. Grab bars shall be 6 inches (150 mm) maximum from the adjacent wall. 608.3.3 Alternate Roll -in -Type Showers. in alternate roll -in type showers, grab bars shall be provided on the back wall and the end wall adja- cent to the seat. Grab bars shall not be provided above the seat. Grab bars shall be 6 inches (150 mm) maximum from the adjacent wall. 608.4 Seats. A folding or nonfolding seat shall be provided in transfer -type shower compartments. A seat shall be provided in an alternate roll -in -type shower compartment. In standard and alternate roll - in -type showers where a seat is provided, if the seat extends over the minimum clear inside dimension required by Section 608.2.2 or 608.2.3, the seat shall be a folding seat. Seats shall comply with Sec- tion 610. 6 max 950 back wall 40 o end end r' Er wall wall Li (b) With Seat Fig. 608.3.2 Grab Bars in Standard Rollin -Type Showers ICC/ANSI All 7.1-2003 6 max 6 max 150 150 back wall gin E end side wall11L1wall :1 seat wall Fig. 608.3.3 Grab Bars in Alternate Roll -in -Type Showers EXCEPTIONS: 1. A shower seat is not required to be installed in a shower facility for a single occupant, ac- cessed only through a private office and not for common use or public use, provided rein- forcement has been installed in walls and lo- cated so as to permit the installation of a shower seat complying with Section 608.4. 2. In Type A units, a shower seat is not required to be installed where reinforcement comply- ing with Section 1003.11.9 is installed for the future installation of a shower seat. 608.5 Controls and Hand Showers. Controls and hand showers shall comply with Sections 608.5 and 309.4. 608.5.1 Transfer -Type Showers. In transfer - type showers, the controls and hand shower shall be located on the control wall opposite the seat, 38 inches (965 mm) minimum and 48 inch- es (1220 mm) maximum above the shower floor, within 15 inches (380 mm), left or right, of the centerline of the seat. Can be located on any wall of shower o N CD C N [�3 (a) Without Seat Chapter 6. Plumbing Elements and Facilities q 15 max 380 ' 9 o control F cc" wall T E tO CCC) 0) Fig. 608.5.1 Transfer -Type Shower Controls and Handshowers Location 608.5.2 Standard Roll -in Showers. In stan- dard roll -in showers, the controls and hand shower shall be located 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum above the shower floor. In standard roll -in show- ers with seats, the controls and hand shower shall be located on the back wall, no more than 27 inches (685 mm) maximum from the end wall behind the seat. 608.5.3 Alternate Rollin Showers. In alter- nate roll -in showers, the controls and hand shower shall be located 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum above the shower floor. In alternate roll -in show- ers with controls and hand shower located on the end wall adjacent to the seat, the controls and hand shower shall be 27 inches (685 mm) maximum from the seat wall. In alternate roll -in showers with the controls and hand shower lo- cated on the back wall opposite the seat, the (b) With Seat Fig. 608.5.2 Standard Roll -in -Type Shower Control and Handshower Location _ E cq Ln co N CO Of N T Q7 59