Loading...
Bldg Revision Comments 6-27-08.pdfDATE: June 27, 2008 City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425)771-0220 TO: Charles Greenberg FAX: 425-672-7867 FROM: Ann Bullis, Assistant Building Official RE: Revision to Permit #2005-0722 Project: Response to Field Corrections Project Address: 155 3rd Ave South During review of the documents submitted in response to field corrections, we have the following comments: 1. Listed and Tested Fire Stopping Assemblies (item 7 of 4/18/07 corrections). On 6/26/08 the City received only the specification sheet for Firetemp CE by Johns Manville. The listed and tested assemblies were not received. Firetemp CE is only a product noted within an assembly. Johns Manville has numerous listed and tested assemblies on their website. Your contractor can go to this website, download the "download binder" (see attached copy of website page) and select a UL or WH listed and tested assembly for each type and size of penetration of fire rated walls, floors and ceilings to submit for City review. If there are penetrations that are not covered in the listing on the JM website, contact them directly for help. Fire stopping assemblies has been discussed with your contractor both on the phone and in the field (as well as with the plumbing contractor at the counter). 2. Geotechnical Special Inspection Reports (items 1 & 10 of 4/18/07 corrections): On 6/12/08 the City received special inspection reports from Earth Consultants for soil bearing verification. We are still awaiting special inspection reports for grading, temporary shoring, placement of fill and compaction. 3. Structural Special Inspection Reports (items 1 & 11 of 4/18/07 corrections): On 6112108 the City received special inspection reports from Otto Rosenau & Assoc. for spray -applied fire proofing (dated 2/15/07), welding and high-strength bolting for structural steel construction (dated 10125106), and concrete/rebar inspection for footings only (dated 3/28/06). We are still awaiting special inspection reports for epoxy anchors, foundation wall rebar and concrete, and for spray -applied fire proofing applied due to framing changes made after 2115/07. Special inspection is not required for masonry since this was changed to solid concrete under the structural revision. 4. Shop drawings (item 1 & 13 of 4/18107 corrections). On 6/12/08 we received a shop drawing for reinforcement only (dated by engineer on 2/22/06). We are still awaiting shop drawings for prefab. 1 -joists and roof trusses, open web steel joists/girders, and structural steel fabrication. Additional follow-up items: • Refer to e-mail dated 6/20/08 from Jeannine Graf, Building Official regarding the structural .revisions (item 2 of 3/26/08 corrections), architectural revisions (item 4 of 3/26/08 corrections -- also plan review corrections attached dated 3/31/08), and structural engineer's inspection report (item 3 of 3/26/08 corrections). • Plumbing Inspection: Once all items in City notice dated 4/2/08 have been corrected, call the Building Inspection Hotline and schedule an inspection. • Mechanical Inspection: Once all rough -in mechanical systems have been installed, call the Building Inspection Hotline and schedule an inspection. During a phone conversation on 6/20108 with John Holte, he mentioned that he wanted to change the location of the garage exhaust shaft. I recommended that he discuss this with the mechanical engineer first since the code is very restrictive regarding the outlet location. I also told him that revised mechanical, architectural and possibly structural plans would be required, and possibly ADB review would be required if it affected the exterior of the building. Revised plans must be stamped and signed by the design professional of record (one copy of each must be wet signed). • Framing Inspection: Before framing can be inspected by the City: o All outstanding correction items must be satisfactorily addressed. o Rough -in of plumbing and mechanical systems must be complete and signed off by the City. o Cover approval by the State Electrical Inspector must be obtained. o Cover approval by the Fire Marshal must be obtained. o Structural revisions must picked up and outstanding fees paid. Page 2 of 2 Johns Manville - Firestopping to view PDF files Firestopping Caulk FreEemp�. C';E FiretempOO CI Spray Firetemp® SE Firetemp® SI Sealants Firetemp® SL Accessories Firetemp® Plastic Pipe Collar (PPC) Firetempt Wrap Strips Firetemp® Intumescent Put . Pads Firetemp® Intumescent EBI Listings Search General In Co_ _rmation Installation Approvals Download Binder suppoft Email Us Page 1 of 1 httpa/www.imfirestopping.com/ 6/27/2008 Qr Ego City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: March 31, 2008 TO: Charles Greenberg FAX: 425-672-7867 FROM: Ann Bullis, Assistant Building Official RE: Revision to Permit #2005-0722 Project: Architectural Revision for New Mixed Use Building Project Address: 155 3rd Ave South During review of the revised architectural plan for the above noted project, it was found that the following information, clarifications or changes are needed. Provide written responses to each comment and where changes can be found on the plans. Please resubmit to Marie Harrison, Permit Coordinator. 1. During the original plan review for this project, the design professional of record chose to use IBC 1025.1 exception 6 for emergency egress from sleeping rooms. This requires a 3068 side hinged exit door to be provided from the bedroom to the exit balcony (as shown on the original approved plans). The sliding door how shown is not permitted and must be changed back to a 3068 side hinged exit door, unless the design professional of record determines another approved method of emergency egress from the sleeping room. 2. Reference door type #2 on the floor plan for both bedrooms. 3. The revised plans must be stamped and signed (one copy wet signed) by the design professional of record, Chris Covington, P.E.