Loading...
BUILDING COMMENTS 1.pdfof EDS City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION Esr 1g90 (425) 771-0220 DATE: October 27, 2006 TO: Monte Clouston FAX: 541-318-3400 FROM: Ann Bullis, Assistant Building Official RE: Plan Check #2006-1145 Project: Calais Multi -family --Residing Project Address: 1115 4"' Ave S During review of the plans/documents for the above noted project, it was found that the following information, clarifications or changes are needed. Please submit written responses to the comments below, including where changes can be found on the plans, and 2 sets of revised plans/documents (affected sheets only) to Theresa Umbaugh, Permit Coordinator. 1. Exterior walls, deck floor -ceilings, deck roof -ceilings, and soffits must be 1 -hour fire rated. Provide listed and tested 1 -hour assembly for each, including details and listing references (e.g. from IBC Chapter 7 tables, Gypsum Association, UL, etc.). Provide floor plans and building sections to clearly show where the assembly details apply. 2. Clarify if any interior sheetrock will be removed as part of this permit. If so, clearly show/describe the locations, clearly show the 1 -hour fire rated assemblies, insulate the exposed wall and ceiling cavities with insulation to the maximum extent possible (for example, R-15 for 2x4 walls), and fire stop all penetrations of fire rated assemblies. 3. Clearly note/show on the plans if window and door sizes will be reduced or enlarged in size. If they will change in size, clearly show on the plans minimum sleeping room egress requirements, natural light/ventilation requirements, headers, etc. 4. On deck guard detail 6f/WP001 dimension the minimum height of the guard from the finished floor of the deck. 5. The Planning Division is requesting paint samples of the proposed exterior colors, and color photos of the existing building. Please contact Gina Coccia, Planner, if you have questions. Prior to final Building inspection/occupancy, the Building Enclosure Inspector must submit a signed letter certifying that the building enclosure has been inspected in substantial compliance with the building enclosure design documents. Where phasing of construction occurs, coordinate inspection with the City Building Inspector to insure that all required inspections are performed. Inspection by the building enclosure inspector to meet EHB- 1848 does not substitute for required City building inspections which must be performed by the City Building Inspector. We ate still waiting for the daily special inspection reports to be submitted by your Engineer of Record for the carport repair and retaining wall construction. He noted in his last correspondence that this would be submitted by 10/20/06. We have not received them. Please provide copies upon receipt of this letter.