BW_PDF.pdfEXISTING WALL
EXHAUST VENT
ABOVE
"HAND WASH
ONLY"
SiGNAGE
INSTALL FRP CO ALL
WALLS OF KITCHEN
(FLOOR TO CEILING)
MiN 111 CFM OUTDOOR
AiR REQ'D PER 1MC
TABLE 403.3.1.1
REMOVE EX DOOR
TO BE FRAMED
OPENING;
INSTALL CURTAIN
FOR PRiVACY-
�I I NEW BEAM PER
STRUCTURAL —
"HAND WASH
ONLY"
SiGNAGE —
C�
X
w
NEW POST PER
STRUCTURAL—
MiN 440 CFM
OUTDOOR AiR REQ'D
Cad BAR AND LOUNGE
A PER 1MC TABLE
403.3.1.1
MAIN FLOOR PLAN
5CALE:1/4" = 1'-O"
61/2" NEW 42" G U RDRAiL
a� POSTED EXiT SiGN
0
0
N cs) EXi 3TII 4G
w ( D EX ELEC PANEL;
EX GAS w CZ 03 UPGRADE A5 REQ'D
METER X1 TiN O z w Xi TING
cn
J ° SANDWICH REF -----; REF
PREP
SiNK
z9 II II 1 II - - ME�,H/STO
�Q II / \ II II FRZR VINYL
11
WH
4'-61/8" Z
p v /' REF ~
5HLV5 w
w 2'X3' w
KITCHEN K I� DOOR TO EX
L- DN
EX LVT () Q FRAMED
I SiNK 1 I OPENING /
EE1
]J
— ° i 1 �S Im cn
I x < STORAGE >
__" I`� EX HARDWOOD "�
XiSTiNG
28
DOOR SCHEDULE
ID
R.O. DIMENSIONS *SEE NOTE 1
DOOR LEAF DIMENSIONS
WIDTH
HEIGHT
W
HT
TYPE
THICK
AREA
NSF)
NOTES
MAiN FLOOR T.O. SUBFLR
EXISTING SHOWER;
REMOVE DOORS TO BE
01
6-2"
6-101/2"
6'-0"
6'-8"
PATIO SWING
0'-13/4"
40.00
(PR) 3'-0" DOORS TO PATIO; TEMPERED;
MOP SiNK
02
3'-2"
6'-91/2"
3' -0"
6'-8"
ENTRY SWING
0'-13/4"
20.00
MAiN ENTRY DOOR; TEMPERED; EGRESS
03
3'-2"
6-91/2"
6-8"
SWING
0-13/4"
20.00
BACK ENTRANCE DOOR; EGRESS
04
T/1T A 1 T VT r"Y]I ll/1n • r�
3'-2"
w
6-91/2"
_..
6-8"
SWING
O'-13/8"
0.00
0
0
WINE
Z
Z
STORAGE
w
=
EX HARDWOOD
REF N x
EX BATH EXiSTiN
x
X VINYL 28
1 li Lu
SHELVING
Q
�\ ( OFFICE/ <
;
`-STORAGE
HALL
EX HARDWOOD
w
w
J
Q
0
Z)
0
PRIVATE '
LOUNGE 24'
EX HARDWOOD
I
32"
iCE
_tsi_
/
I
In
REF
� 1
I
TAP51
1
/
I
ac 0)
1
__=
I
1
BAR
ICE
°
ozLU
HARDWOOD
�lz
I
z
—
lo
D
/
F --
0
FE
EX HDWD
32
i — —1 EXISTING
I z I>
z I wIQ
LOUNGE C
v EX HARDWOOD
I
I II
I
I II
I I II
I I
I
i
l
l
l
II
I
II
I
II
TEMP
TEMP
TEMP
L `S SCHED. L
AS I_
TYP ENTRY SWING DOOR TYP PATIO SWING DOOR
EXTERIOR
LJ x °' EXISTING BRICK
3' 2" (6'11w i
MiN 75CFM OUTDOOR
AiR REQ'D PER iMC
TABLE 403.1.1
t=
+ - -o
' N
� O �
i (V uj
M-3 NEW
o w
j lzD LOUNGE B w
0)13 24' EX HARDWOOD
xIQ
I�Lu
I J
NEW
1—EX15-r —1 EXISTING
0
I (ABOVE)
I
rn
1 - -«3- - J
04
J
z
FH
48
;�
BATH
Lu
VINYL
_
42
o '
BENCH "�6
w
z,
LOUNGE A N
HP.<C'vVOOC
EU Ri HT
iA 0 32
EX15TiNG EXISTING
DECK
CEDAR DECKING
39" WD GUARDRAIL
INTERIOR
/ EXISTING AiR SPACE
EX15T1NG BUILDING PAPER
--'--EXISTING SHEATHING
_EXISTING 1\ / XiSTiNG FRAMING
MiN 84CFM OUTDOOR /
iNSULATiON
AiR REQ'D PER iMC EXISTING GINB \
TABLE 403.1.1
TYP EX EXTERIOR WALL ASSEMBLY
10,
/
/
/
` EGRE
36
r
r 1
_ _8_
z
ENTRY
- HARDWOOD
w GATE
Q DN
oc
W�
REPLACE EX LAV W/
16"xl5"+/- LAV TO MEET
CLEARANCE REQT5 PER
iCC A117.1-2009 SEC 604.3
RELOCATE TOILET
INSTALL REAR, 51DE, AND
VERTICAL GRAB BARS PER
iCC A117.1-2009 SEC 604.5
POSTED EXiT SiGN;
ACCESSIBLE ROUTE
-POSTED OCCUPANCY SiGN
PER i13C 1004.3
PARTIALLY iNFiLL
EXISTING WINDOW
POSTED DIRECTIONAL
SiGN TO NEAREST
ACCESSIBLE ROUTE
PER iBC111.2 AND iCC
A117.1
1:12 SLOPE
-ADA COMPLIANT NON -CIRCULAR HANDRAIL 0 RAMP:
-4"MiN - 61/2"MAX PERIMETER
-21/4" MAX CROSS-SECTION DIAMETER
-HANDRAIL SURFACES AND ANY AW SURFACES SHALL
BE FREE OF SHARP OR ABRASIVE ELEMENTS AND
SHALL HAVE ROUNDED EDGES
TABLE 403.3.1.1 MINIMUM VENTILATION RATES
o
i
<
AS SCHED,
TYP SWING DOOR
OCCUPANCY
PEOPLE OUTDOOR AIRFLOW
AREA OUTDOOR AIRFLOW
OCCUPANCY
DENSITY
RATE iN BREATHING ZONE
RATE iN BREATHING ZONE
CLA551F1CATi0N
#11000 FT2
Rp
Ra
CFM/PER50N
CFM/FT2
FOOD ANO BEVERAGE
SERVICE:
BARS, COCKTAIL
LOUNGES
100
7.5
0.18
OUTDOOR AIRFLOW RATE = Rp X ZONE POPULATION + Ra X ZONE FLOOR AREA
VENTILATION BAR AND LOUNGE A = 7.5X48 + 0.18X442.5=360+79.6 = 440 CFM MiN.
VENTiLATON LOUNGE B = 7.5X9 + 0.18X89 = 67.5+16 = 84 CFM MiN
VENTILATION LOUNGE C = 7.5X8 + 0.18X80.2 = 60+14.4 = 75 CFM MiN
VENTILATION PRIVATE LOUNGE = 7.5X12 + 0.18X113.3 = 90+20.4 =111 CFM MiN
GROSS FLDOR AREA (MEASURED FROM INSIDE OF EXTERIOR WALLS)
EXISTING MAIN FLOOR AREA
1,695 5F
NEW OIJ-Df. 4)R PATIO AREA
310 5F
EXISTING -ONER FLOOR AREA
121 SF
TOTAL CONCiT10NED AREA
1,695 5F
NOTES:
1. EGR
- PANIC HARDWARE SHALL BE LISTED iN ACCORDANCE WiTH UL 305
- FIRE EXIT HARDWARE SHALL BE LISTED iN ACCORDANCE WiTH UL 10C AND UL 305
- THE ACTUATING PORTION OF THE RELEASING DEVICE SHALL EXTEND NOT LESS THAN ONE-HALF OF
THE DOOR LEAF WiDTH
- THE MAXIMUM UNLATCHING FORCE SHALL NOT EXCEED 15 POUNDS 67 N)
2. ALL
A117.1-2009 SECTION 404.2.6.
REQUIRING TiGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE PER iBC 1010.1.9.1/iCC
3. VERIFY ALL SIZES AND ROUGH OPENINGS PRIOR TO CONSTRUCTION
4. CONTACT ARCHITECT IMMEDIATELY WiTH QUESTIONS.
NOTES:
1. ALL DIMENSIONS ARE GIVEN TO THE FACE OF STUD UNO.
2. ALL DOOR AND WINDOW DIMENSIONS ON THIS PLAN ARE ROUGH OPENING SIZES,
UNO. REFER TO WINDOW AND DOOR SCHEDULE FOR MORE INFORMATION.
3. SEE ATTACHED WSEC FORMS FOR ENERGY CODE COMPLIANCE INFORMATION.
4. INSTALL SMOKE DETECTORS (S.D.) AT LOCATIONS SHOWN. HARDWIRE AND
INTERCONNECT DETECTORS TO POWER SUPPLY AND PROVIDE BATTERY BACKUP
A5 REQUIRED.
5. PROVIDE A MiNiMUM OF 1-2AlOBC FiRE EXTINGUISHER (BAR) AND 1-K TYPE FiRE
N EXTINGUISHER (KITCHEN).
❑ EXISTING WALLS
NEW WALLS
v!
J
Q
O
N
CD
00
U
U)
Q
O
z
U
U)
O
U-)
o
z
�
2
z
o
J
W
w
9716 REGISTERED
ARCHITE�CT�,,
HEIDI MICHELLE HELGESON I
STATE OF WASHINGTON
H 2 D
A R C H I T E C T U R E
+
D E SI G N
23020 EDMONDS WAY, #113
EDMONDS, WA 98020
P. 206 54 2 3 7 34
www.h2darc h i tects.c om
DATE: 3/20/2018
REVISED: 5/2/2018
PERMIT SET
MAIN FLOOR PLAN, DOOR
SCHEDULE
REBUB
MAY [ 4 2018
omsmwr