Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
C-3.0 UTILITY PLAN.pdf
E I r` 0 N 0 a, Q 01 0 H C C 25LF 8" PVC SS @ 2.0% MIN EX FIRE HYDRANT TO REMAIN i 0 0 \ O O WNP n Know what's below. Call before you dig. GRAPHIC SCALE 20 40 ( IN FEET ) 1 inch = 20 ft. No. Date By Revision Description 1 07/14/2017 PACLAND BUILDING PERMIT REVIEW #1 2 08/01 /2017 PACLAND BUILDING PERMIT REVIEW #1 (FIRE) A O„ CO Designed By: Issue Date: LRR 08/01 /2017 PERMIT Drawn By: CMD Checked By: Project No: WFF 10-382-001 � SS Sp SECTION 25, TOWNSHIP 27 N, RANGE 3 E STRUCTURES 01 jj " 02 jj�" / J SSCO RIM=314.08 RIM=314.50 RIM=314.76 IE 8"=308.34 IE 8"=308.90 IE 8"=309.20 WATER FITTINGS/CONNECTIONS 01 1-8" 90° BEND <8>1-8%8%6" TEE 07 1-6" 90° BEN 1—THRUST BLOCK 1—THRUST BLOCK 1—THRUST BL 02 1-8" 45° BEND <0>1-3" 90° BEND 1—THRUST BLOCK 2 03 1-8' 22.5° BEND 06 1-1' 90° BEND 1—THRUST BLOCK L7li\\IhOWN LDIVL64mk1lf1 ml!f� ro ,NT O �O tiA A w\ FIRE LANE �� Wv 011 EX FIRE HYDRANT TO REMAIN 3 EX WATER LINES WERE NOT LOCATED DURING SURVEY, AND ARE REPRESENTED BASED ON LOCATION OF EXISTING VALVES AND APPURTENANCES, AND UTILIZING AVAILABLE INFORMATION FROM OLYMPIC VIEW WATER AND SEWER DISTRICT; LOCATION IS TO BE TAKEN AS APPROXIMATE ONLY o �t _ "�G 96 SB cv�cv iwHW DJAA(r � � � 1505 Westlake Ave. N. T (206) 522-9510 Suite 305 F (206) 522-8344 Seattle, WA 98109 WWW.PAcLAND.COM WESTGATE MIXED USE EDMONDS WAY AND 100TH AVE W EDMONDS. WA CONSTRUCTION KEY NOTES OA CONNECT TO EX SEWER (SEWER LOCATION IS APPROXIMATE; C-5.o CONTRACTOR TO FIELD VERIFY LOCATION AND INVERT ELEVATIONS PRIOR TO CONSTRUCTION) © CONNECT TO EX WATER 2 © SANITARY SEWER CLEANOUT c-s.o 2 OD GREASE INTERCEPTOR c-s.o OE RELOCATE EX LIGHT POLE; COORDINATE WITH UTILITY PROVIDER OF FIRE DEPARTMENT CONNECTION © DOMESTIC WATER METER (Y), BACKFLOW PREVENTER TO BE LOCATED INSIDE BUILDING OH EX WATER METER TO BE RETAINED FOR IRRIGATION SERVICE (D FIRE RISER ENTRY OJ DOUBLE CHECK VALVE ASSEMBLY OK DOMESTIC WATER ENTRY © CONNECT TO EX ELEC; COORDINATE WITH UTILITY PROVIDER OM CONNECT TO EX GAS; COORDINATE WITH UTILITY PROVIDER ON POST INDICATOR VALVE O GAS METER © 8" SEWER ENTRY ® RELOCATE GUY WIRE AS NEEDED FOR CLEARANCE; COORDINATE WITH UTILITY PROVIDER ® DOUBLE CHECK DETECTOR ASSEMBLY LEGEND 1 WATER LINE W W C-7.2 C-5.0 SIDE SANITARY SEWER ss— 2 WATER METER ■ C-7.o GATE VALVE N FDC $ C-7.1 THRUST BLOCK • PIV 2 DCDA C-7.2 2 DCVA C-7.2 2 SS CLEANOUT C-5.0 3 kGREASE INTERCEPTOR • • • C-5.0 TELEPHONE T T SHOWN SCHEMATICALLY; POWER UGP COORDINATE W/ UTILITY GAS LINE G G PROVIDER APPROVED FOR CONSTRUCTION OLYMPIC VIEW WATER &SEWER DISTRICT DATE: UTILITY PLAN C-3.0