Loading...
CafeDeParisRev.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: July 17, 2007 TO: Terry Marcell TGMarcell@hotmail.com FROM: Ann Bullis, Assistant Building Official RE: Revision to Permit #2006-1391 Project: Café De Paris Remodel Project Address: 109 Main Street During review of the revised plans for the above noted project, we have the following comments. 1.As noted previously in past plan review comments for this project, the west exterior wall of the building is less than 3 feet to the property line, therefore no openings are permitted per IBC 704.8. The manufacturer’s information submitted for Pyrostop fire rated glazing states that the frame has been tested to meet ASTM E-119. The glazing is still an opening and is not permitted as noted previously above. 2.The revised plans also show that infill at the opening area will be “2x6 wall with 2 layers GWB”. a.Provide a 1-hour wall construction detail. The wall must be non-combustible, including studs, siding, insulation, etc. b.Provide 1-hour listed and tested fire rated exterior wall assembly. c.Provide 1-hour listed and tested joint assembly where the stud framing adjoins the CMU. Please follow the approved plans issued under Permit #2006-1391.