Memorandum
MAR 14 2DIL
To: City of Edmonds Building Inspector
From: C. Chevy Chase, PB, SE
Date: January 4, 2008
Re: Cambridge Condominiums Dry Rot Repairs (Permit No.'s: BLD20071183,
BLD20071184, BLD20071186, BLD20071186, BLD20071187) ll�?.4a7 ~ C11rl
It is our understanding that the City's Inspector was unable to view the nailing patterns of the
plywood during the framing inspection. Based on the original approved plans, the walls where
plywood was replaced were not shear walls. Therefore the minimum nailing required for 15132"
sheathing per IBC 2006 Table 2304.5.1 is 6d common nails spaced at 6 -incites on center at edges
and 12 -inches on center at intermediate supports.
Based on photographs of the nailing patterns taken during the repairs and correspondence with the
contractor, these minimum nailing requirements were met.
SVY C
t �
TEg�'q
10 L �
SPIRES: 7 1? z 08
NOTES:
1. CONTRACTOR SHALL CONTINUOUSLY MONITOR EXISTING FRAMING DURING REPAIRS FOR POTENTIAL
DEFORMATION CAUSED BY UNOBSERVABLE DRY ROT, AND NOTIFY CG ENGINEERING IMMEDIATELY IF
DEFORMATION IS OBSERVED.
2. WE RECOMMEND THAT THE CONTRACTOR TREAT ALL STAINED WOOD MEMBERS PER RECOMMENDATIONS
OF A MOLD REMEDIATION CCNSULTANT.
STEEL ANGLE FOR TEMPORARY -
SUPPCRT OF EX. 6x10 HDR.
REMOVE DRY -ROTTED BOTTOM—
PLATE AND REPLACE W/ LIKE
KIND WHILE TEMPORARY
SHORING IN PLACE.
EX. 6x10 i HEADER
SUPPORTING BUILT-UP
STUD COLUMN ABOVE.
INSPECT EX, POST BELOW FOR DRY
ROT NOTIFY CG ENGINEERING IF
FOUND TO BE ROTTED.
TEMPORARY SHORING PLAN PARTIAL THIRD FLOOR FRAMING SHOWN
SCALE: 1/4!' = 1'-0" <t
C C
CAMBRIDGE CONDOS DRY AOT REPAIR
Cep12/0f/07
cauaNG AD.
630 WALNUT ST. UNIT #201
� eCI No,07M.10
ENGINEGFZM
EDMONDS WA 88020
S= '/l -V
'gE TEMPORARY SHORING PLAN
moo=• mow„
DRAD` 1°'
,
Piwxe caws ne-esoa
CHS wu
eAx �an� ne-ssse
APPMAD of Ctt
/2' L6x6x3/8 x 0'-6" W/ (6)-5/8"0 x 4" LAG
SCREWS INTO END OF EX. 6x10 HEADER
1" AND (4)-5/8"0 x 4" LAG SCREWS INTO
'^ EX. 7 x 11 1/4 RSL (10 -TOTAL)
f EXISTING 7 x 11 1/4 PSL
iK—
O O
O O
EXISTING 6x1O
HEADER
TEMPORARY SHORING DETAIL
SCALE: 1 1/2" = 1'-0"
� �j"qy
�
G� C�
.23125 � 1w
EXPIRES; 7/6/2008
CAMBRIDGE CONDOS DRY ROT REPAIR
DATE 12/04/07
DWiV19NG N0.
630 WALNUT ST.
Pi20JEcr No-. 07253.10
ENGINEERING
EDMOND3 WA. 98020
SCALE i t/z•=]'-o'
TEMPORARY SHORING DETAIL
OU Ini" . s., TO?l
sauoNnE WASFIfHGB-
�i�Eo ire
e;7 n
til -2
se6sa
020
PHOHE (125) 776-SSaO
�
FAY (125) 778-SS36
APPROVED BY
NAR f 2008
tclCry,d
GfTy g 0�fPAM'f'?s§LNs_
��(ifVf1
11
MIN.
NOTES:
1. PROVIDE A MINIMUM OF (2) -HOLES PER STEEL. ANGLE AND
(1) -HOLE WITHIN 5" OF FROM EACH END.
ADDITIONAL HOLES FOR EX. L6x4xl12
SCALE: 3" = 1'-O"
V,NY
237
8T�g`�9
Cs
SINAL � vA
EXPIRES; 7 6 2008
CAMBRIDGE CONDOS DRY ROT REPAIR
DATE 12/04/07
DMWING NO.
530 WALNUT ST.
PROD€cT NO. 07203.10
ENGINEERING
EDMONDs WA. 98020
sckE
ADDITIONAL HOLES FOR EX. L6x4xl/2
SNGSURE
CHE�E 8Y klcv
SS-�`
WORM 9U2D
PHOHE (125) 776-0
850
iAx {125) 778-5539
APPROVED HY OCC
2x6 STUD WALL
ATTACH BRICK TO STUD WALL
W/ ANCHOR TIES @ 24" O.C.
5/8"0 x 5" LAG SCREWS @
9" O.C. MAX. SPACING W/
MIN. (2) PER STEEL ANGLE.
RE—OSE L6x4x1 /2. PROVIDE
ADDITIONAL HOLES PER SS -4
1„
GAP.77
ON A35
DE
iF#2
ING
3d TOE NAILS EA.
f BLKG.
RI
TYPICAL BRICK VENEER CONNECTION DETAIL
SCALE: 1 1/2" = l'-0"
�Wy c4v
�.V'4 O� �Tttpl'�
GtsTF
0NAL
EXPIRES: 7/6/2008
CAMBRIDGE CONDOS DRY ROT REPAIR
GATE 12/04/07
ORAVMG NO.
530 WALNUT ST.
PROJECT NO. 07236.10
ENGINEERING
EDMONDS WA. 98020
scut: 11/2'_1'-0•
TYPICAL BRICK VENEER CONNECTION
EUYOND5, WAVNOTOH $8020
DRAWN BY
S _
PHONE (425) 778-SWO
FAX (425) 778-5535
n
DETAIL
C1tECKEO t m
A(fA[
APPROM
fff CCC
Page 1 of 1
Bullis, Ann
From: Mike Maechler [mikem@cgengineering.com]
Sent: Friday, March 14, 2008 8:43 AM
To: Bullis, Ann
Subject: Cambridge Condos
Ann,
Please see the attached pdf, which includes all of the documents we issued to the contractor to keep on site for the
Cambridge Condos. There is a memo regarding nailing of the sheathing, temporary shoring plans and details, and (2)
details for the re -attachment of the brick veneer support angle. Note that SS -3 is missing as it was never used or issued.
Feel free to call or email me with any questions you have.
Thanks,
Mike Maechler
CG Engineering, PLLC
2504th Ave. South, Suite 200
Edmonds, WA 98020
P (425) 778-8500
F (425) 778-5536
RF 'OJ F
MAR
3/14/2008