Loading...
Carlson1.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: June 2, 2008 TO: Karl Schmidt e-mail: karl-f-schmidt@comcast.net FROM: Ann Bullis, Assistant Building Official RE: Revision to Permit 2008-0413 & 0417 Project: Carlson Deck and Hot Tub Project Address: 1439 Olympic View Drive. During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Plans on file may be redline by the architect, or resubmit revised plans/calcs to Marie Harrison, Permit Coordinator. Coordinate redlining of plans with the permit coordinator. 1.Guardrail required at deck to protect falls of more than 30”. Where a bench is provided as part of the guardrail, the guardrail is measured from the seat of the bench. Clearly show on the plans where the fall exceeds 30” and revise guardrail detail at these locations. 2.Detail 3/A1.4, revise guardrail to meet the minimum height of 36” at the stairway.