BLD20070659
May23,2007
Permit:Date:
#
GormanGAR/101CaspersSt
Project Name/Address:
Contact Person/Address/Fax:
__________________________________________________________________________________________
__________________________________________________________________________________________
RobertGorman/R.GORMAN@COMCAST.NET
Engineering
EdwardSibrel
Reviewer: Division:
During review of the subject submittal it was found that the following information, corrections, or
clarifications will need to be addressed:
Detention/Drainage:
Unabletodeterminetheexactextentofwhichtheinstallationofthe"SFRima"pavers,installedina
"waterdrainage"configurationpertheMutualMaterialsproductcirculars,willactuallyreducethe
amountofrunoffovermoreconventionalimpervioussurfaceinstallationsfordriveways.Thepaver
installationinstructionsthemselvesrecommendtheuseofanengineer'sserviceswhenpaversare
usedinthesesituations.
Asoilsreportandperctestsspecifictothedrivewayinstallationwillberequiredinordertoassess
theinfiltrationpropertiesoftheunderlyingsoil,particularlywhenundervehicleloadsandwithits
surfaceareareducedbythepresenceofthepavers.Weexpectthattheuseofthepaverswill
reducetheeffectiveimpervioussurfaceofthedriveway,butnoteliminateit.
Please resubmit three copies of the revised plans/documents to a Development Services Coordinator. You
may contact me at 425-771-0220 if you have specific questions regarding these plan corrections.
5/23/20081
DATE mailed/faxed/emailed PAGE OF.