CHILR Chillers.pdf Mar 26, 2015 Submittal Review Swedish Edmonds ACCMarch 17, 2015 Project:Date: of 1 1 Page: Andris Lapins - NBBJ Architect: Scott Solberg - SellenAdam Bettcher Contractor:Reviewed by: NO EXCEPTIONS TAKEN REJECTED MAKE CORRECTIONS NOTED SUBMIT SPECIFIED ITEMS REVISE AND RESUBMIT SUBMITTAL NOT REQUIRED & NOT REVIEWED This review is only for general conformance with the design concept of the project and general compliance with the information given in the contract documents. Corrections or comments made during this review do not relieve contractor from compliance with the requirements of the drawings and specifications and do not authorize changes to contract cost. Contractor is responsible for: Dimensions which shall be confirmed and correlated at the job site; fabrication process and techniques of construction; coordination of his work with that of all other trades; performing his work in a safe manner. Sparling has reviewed the copy of submittal 135-230548001-1 – Seismic and Vibration for Mechanical Equipment received electronically on March 3, 2015, and our comments are as follows. (Note: All of our review comments are contained in this document. There are no markups on any of the information sheets submitted.) This submittal is a revision of the previous vibration isolation submittal. Sparling requested that the submittal be revised and resubmitted due to discrepancies between the spec and the submittal for the S-3 spring isolator that was located on the chiller. Specifically, a neoprene pad needed to be inserted between the spring and the plate, along with a loading distribution mechanism. The revised submittal (Revision 3, the most recent revision from VMC) places ‘Custom MS-2E vibration isolators with integral seismic restraint with Maxi-Flex Pads for 2” deflection’ on the chillers. These pads replace the original neoprene cup of the spring with VMC “Gray” elastomeric pads set beneath a metal plate. The submittal does not appear to specify the thickness or shape of the Maxi-Flex Pads pads, which should be ¾” to 1” thick. Please submit information on this product, such as specific cutsheets, and specify the thickness. Maureen Jackson – Sparling cc hb:B17787\\SR 230548.001 4100 194th St SW • Suite 400, Lynnwood, Washington 98036-4613 206-667-0555 800-667-0610 Fax: 206-667-0554 www.sparling.com 1 | Page SUBMITTAL FOR APPROVAL Submittal #: 135 -230548.001 Rev#: 1 7039. - SWEDISH/EDMONDS-AMBULATORY CARE Priority: Medium CENTER Date: 03/02/2015 To: RACHEL JENNER From: SCOTT SOLBERG NBBJ SELLEN CONSTRUCTION CO., INC. 223 Yale Ave 227 WESTLAKE AVE N Seattle, 98109 SEATTLE, WA 98109 Originator: HERMANSON COMPANY LLP Description: Seismic for Penthouse Equipment REVISED We are transmitting the following Submittal Package item(s) for your review in accordance with the contract specifications. Please review and respond to: SCOTT SOLBERG, by: 3/16/2015. Additional Notes: Item Number Spec Section Description Details Notes 135-001.1 Pump Skids Seismic 135-002.1 Cooling Towers Seismic 135-003.1 AHU & Chiller Seismic 135-004.0 Housekeeping Pad Layout cc: 230548-002.1A Chiller Vibration Isolation Resubmittal 2/25/15 Page # Item # X: Tags - AHU001 Calculate the maximum loading at the most critical restraint location. MfrModelMin. limitActualMax. limit HaakonAHU Ss =1.27ap = 2.5From the tables:Fp/Wp = 0.381 g's1.472 g's2.03 g's z/h =1.0Rp = 2.5Fa = DLE 1.00 Site ClassCIp = 1.5S = Load Combination 11.2 0.846 DS 1 Use GroupIVCalc'd Seismic Design CategoryLoad Combination 20.9 D Input DataCalculated Values WeightHcgXcgYcgHoriz g'sVertical g'sPhxPz MaxPz Min 49380 #65.0"291.0"100.0"1.4720.7311.36972689 #67611 #36087 # Overturning Rigid Weight Seismic Vertical Restraint Locations Iy1Ix1IxyJ1 LoadsDistributionDistribution 2.00"0.00"871731143531573986083226 #3395 #78755708 50.00"0.00"611331143526440725683086 #3378 #77105554 100.00"0.00"389081143521093503432939 #3359 #75385394 150.00"0.00"216831143515746331182792 #3341 #73665234 444.00"0.00"2153611435-15693329711930 #3232 #63564292 494.00"0.00"3871111435-21039501461783 #3214 #61844132 544.00"0.00"6088611435-26386723211637 #3195 #60123972 594.00"0.00"8806111435-31733994961490 #3177 #58403812 594.00"213.87"88061114353173399496-3231 #2777 #571-1202 544.00"213.87"60886114352638672321-3084 #2795 #743-1041 494.00"213.87"38711114352103950146-2937 #2813 #915-881 444.00"213.87"21536114351569332971-2791 #2832 #1087-721 150.00"213.87"2168311435-1574633118-1929 #2940 #2097220 100.00"213.87"3890811435-2109350343-1782 #2959 #2269380 50.00"213.87"6113311435-2644072568-1635 #2977 #2441541 2.00"213.87"8717311435-3157398608-1495 #2995 #2606694 ThetaIy totalIx totalIxy totalJ total0 #49380 #6761136087 Max Reactions per Location 211.3 deg0.546 rad83617518296201019137 Comp (Max Vert) 7875 # Tens. (Min Vert) 1202 # Tanr max# Vertical Restraints# Horizontal Restraints Shear 4753 # 0.607315.4"1616 Concrete analysis requires a 1.3 factor per ASCE7. Increase reactions by 30% and apply to anchor. Pt concPs conc 1562 #6179 # X: Tags - AHUHRC Calculate the maximum loading at the most critical restraint location. MfrModelMin. limitActualMax. limit HaakonAHU Ss =1.27ap = 2.5From the tables:Fp/Wp = 0.381 g's1.523 g's2.03 g's z/h =1.0Rp = 2.5Fa = DLE 1.00 Site ClassCIp = 1.5S = Load Combination 11.2 0.846 DS 1 Use GroupIVCalc'd Seismic Design CategoryLoad Combination 20.9 D Input DataCalculated Values WeightHcgXcgYcgHoriz g'sVertical g'sPhxPz MaxPz Min 9360 #57.4"105.1"57.8"1.5230.7311.36914253 #12816 #6840 # Overturning Rigid Weight Seismic Vertical Restraint Locations Iy1Ix1IxyJ1 LoadsDistributionDistribution 2.00"0.00"1063534006013140353066 #1573 #52214216 105.13"0.00"03400034001783 #1573 #39382933 208.25"0.00"106353400-601314035501 #1573 #26551650 208.25"116.62"106353400601314035-3066 #1547 #-949-1936 105.13"116.62"0340003400-1783 #1547 #334-653 2.00"116.62"106353400-601314035-501 #1547 #1617630 00 00 00 00 00 00 00 00 00 00 ThetaIy totalIx totalIxy totalJ total0 #9360 #128166840 Max Reactions per Location 220.3 deg0.703 rad4253920400062939 Comp (Max Vert) 5221 # Tens. (Min Vert) 1936 # Tanr max# Vertical Restraints# Horizontal Restraints Shear 2389 # 0.848118.5"66 Concrete analysis requires a 1.3 factor per ASCE7. Increase reactions by 30% and apply to anchor. Pt concPs conc 2517 #3106 # X: Tags - CHILHR001, 002, 003 Calculate the maximum loading at the most critical restraint location. MfrModelMin. limitActualMax. limit ClimaCoolUCH-85AF Ss =1.27ap = 2.5From the tables:Fp/Wp = 0.381 g's1.904 g's2.03 g's z/h =1.0Rp = 2Fa = DLE 1.00 Site ClassCIp = 1.5S = Load Combination 11.2 0.846 DS 1 Use GroupIVCalc'd Seismic Design CategoryLoad Combination 20.9 D Input DataCalculated Values WeightHcgXcgYcgHoriz g'sVertical g'sPhxPz MaxPz Min 10650 #47.0"51.8"33.5"1.9040.7311.36920272 #14582 #7783 # Overturning Rigid Weight Seismic Vertical Restraint Locations Iy1Ix1IxyJ1 LoadsDistributionDistribution 0.00"0.00"26811122173438031822 #1330 #36432794 34.50"0.00"298112257914212817 #1331 #46393790 69.00"0.00"2971122-57714193812 #1332 #56364786 103.60"0.00"26861122-173638084811 #1332 #66355784 103.60"67.00"2686112217363808-1820 #1332 #4-846 69.00"67.00"29711225771419-2818 #1332 #-995-1845 34.50"67.00"2981122-5791421-3814 #1331 #-1992-2841 0.00"67.00"26811122-17343803-4809 #1330 #-2988-3837 00 00 00 00 00 00 00 00 ThetaIy totalIx totalIxy totalJ total0 #10650 #145827783 Max Reactions per Location 158.8 deg0.369 rad119238978020901 Comp (Max Vert) 6635 # Tens. (Min Vert) 3837 # Tanr max# Vertical Restraints# Horizontal Restraints Shear 2536 # -0.38761.7"88 Concrete analysis requires a 1.3 factor per ASCE7. Increase reactions by 30% and apply to anchor. Pt concPs conc 4988 #3296 # Profis Anchor 2.5.0 www.hilti.us Company:The VMC GroupPage:13 Specifier:Project:Swedish Edmonds ACC Address:11930 Brittmoore Park Drive, Houston, TX 77041Sub-Project I Pos. No.:AHU001 Phone I Fax:713-466-0003 | 713-466-1355Date:2/13/2015 E-Mail: Specifier's comments: 1 Input data Anchor type and diameter: HIT-HY 200 + HAS 1 Effective embedment depth: h = 5.000 in. (h = - in.) ef,actef,limit Material: 5.8 Evaluation Service Report: ESR-3187 Issued I Valid: 5/1/2014 | 3/1/2016 Proof: Design method ACI 318 / AC308 Stand-off installation: e = 0.000 in. (no stand-off); t = 0.500 in. b Anchor plate: l x l x t = 4.000 in. x 4.000 in. x 0.500 in.; (Recommended plate thickness: not calculated) xy Profile: no profile Base material: cracked concrete, 3000, f' = 3000 psi; h = 8.000 in., Temp. short/long: 32/32 °F c Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E, or F) yes (D.3.3.5) Geometry \[in.\] & Loading \[lb, in.lb\] Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan Profis Anchor 2.5.0 www.hilti.us Company:The VMC GroupPage:14 Specifier:Project:Swedish Edmonds ACC Address:11930 Brittmoore Park Drive, Houston, TX 77041Sub-Project I Pos. No.:AHU001 Phone I Fax:713-466-0003 | 713-466-1355Date:2/13/2015 E-Mail: 2 Proof I Utilization (Governing Cases) Design values \[lb\]Utilization LoadingProofLoadCapacity / \[%\]Status aaaaaaaa NV Tension Concrete Breakout Strength1562507531 / -OK Shear Concrete edge failure in direction x+61796841- / 91OK LoadingStatus Utilization \[%\] aaaaaaaayyyyaaaa NVN,V Combined tension and shear loads0.3080.9035/399OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan Profis Anchor 2.4.9 www.hilti.us Company:The VMC GroupPage:15 Specifier:Project:Swedish Edmonds ACC Address:11930 Brittmoore Park Drive, Houston, TX 77041Sub-Project I Pos. No.:AHUHRC Phone I Fax:713-466-0003 | 713-466-1355Date:1/2/2015 E-Mail: Specifier's comments: 1 Input data Anchor type and diameter: HIT-HY 200 + HAS 1 Effective embedment depth: h = 5.000 in. (h = - in.) ef,actef,limit Material: 5.8 Evaluation Service Report: ESR-3187 Issued I Valid: 5/1/2014 | 3/1/2016 Proof: design method ACI 318 / AC308 Stand-off installation: e = 0.000 in. (no stand-off); t = 0.500 in. b Anchor plate: l x l x t = 4.000 in. x 4.000 in. x 0.500 in.; (Recommended plate thickness: not calculated) xy Profile: no profile Base material: cracked concrete, 3000, f' = 3000 psi; h = 8.000 in., Temp. short/long: 32/32 °F c Installation: hammer drilled hole, installation condition: dry Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E, or F) yes (D.3.3.5) Geometry \[in.\] & Loading \[lb, in.lb\] Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan Profis Anchor 2.4.9 www.hilti.us Company:The VMC GroupPage:16 Specifier:Project:Swedish Edmonds ACC Address:11930 Brittmoore Park Drive, Houston, TX 77041Sub-Project I Pos. No.:AHUHRC Phone I Fax:713-466-0003 | 713-466-1355Date:1/2/2015 E-Mail: 2 Proof I Utilization (Governing Cases) Design values \[lb\]Utilization LoadingProofLoadCapacity / \[%\]Status aaaaaaaa NV Tension Concrete Breakout Strength2517507550 / -OK Shear Concrete edge failure in direction x+31064276- / 73OK LoadingStatus Utilization \[%\] aaaaaaaayyyyaaaa NVN,V Combined tension and shear loads0.4960.7265/390OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan Profis Anchor 2.5.0 www.hilti.us Company:The VMC GroupPage:17 Specifier:Project:Swedish Edmonds ACC Address:11930 Brittmoore Park Drive, Houston, TX 77041Sub-Project I Pos. No.:CHILHR001,002,003 Phone I Fax:713-466-0003 | 713-466-1355Date:2/23/2015 E-Mail: Specifier's comments: 1 Input data Anchor type and diameter: AWS D1.1 GR. B 7/8 Effective embedment depth: h = 6.500 in. ef Material: Proof: Design method ACI 318-08 / CIP Stand-off installation: e = 0.000 in. (no stand-off); t = 0.750 in. b Anchor plate: l x l x t = 11.000 in. x 11.500 in. x 0.750 in.; (Recommended plate thickness: not calculated) xy Profile: no profile Base material: cracked concrete, 3000, f' = 3000 psi; h = 8.000 in. c Reinforcement: tension: condition B, shear: condition B; edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E, or F) yes (D.3.3.5) Geometry \[in.\] & Loading \[lb, in.lb\] Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan Profis Anchor 2.5.0 www.hilti.us Company:The VMC GroupPage:18 Specifier:Project:Swedish Edmonds ACC Address:11930 Brittmoore Park Drive, Houston, TX 77041Sub-Project I Pos. No.:CHILHR001,002,003 Phone I Fax:713-466-0003 | 713-466-1355Date:2/23/2015 E-Mail: 2 Proof I Utilization (Governing Cases) Design values \[lb\]Utilization LoadingProofLoadCapacity / \[%\]Status aaaaaaaa NV Tension Concrete Breakout Strength49881756529 / -OK Shear Concrete edge failure in direction x+32964979- / 67OK LoadingStatus Utilization \[%\] aaaaaaaayyyyaaaa NVN,V Combined tension and shear loads0.2840.6625/363OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan PROPRIETARY:EXCEPTASOTHERWISEAGREEDINWRITING,THEINFORMATIONANDDESIGNDISCLOSEDHEREINARETHEPROPERTYOFTHEVMCGROUPANDMUSTNOTBECOPIEDORDISTRIBUTEDOUTSIDETHEVMCGROUPEXCEPTTOAUTHORIZEDPERSONSWITHAGENUINENEE DTOKNOW WHOBYTHEUSEHEREOFACKNOWLEDGETHEVMCGROUP'SOWNERSHIPANDAGREETOMAINTAINTHISINFORMATIONANDDESIGNINSTRICTCONFIDENCE. CERTIFIEDFOR: SALESORDER:CUSTOMERP.O.:CUSTOMER:JOBNAME: HERMANSON SWEDISH 105444 EDMONDS ACC VIBRATIONISOLATORS AMPADTYPENR THEVMCGROUP Bloomingdale,NJ07403 ThePowerofTogether Houston,TX77041 PROPERTIESMAYBESUBSTITUTEDASTHEYBECOMEAVAILABLE. OTHERMATERIALS,COMPOUNDS,ORFINISHESWITHEQUALORSUPERIOR DRAWINGNO.: SHEET:SCALE: VMAB-8800-H NONE 1OF1 REVISION 105444 Swedish Edmonds ACC VMAB-8800-J ” ” ” ” Submittal Approval Page 135.2 Swedish Edmonds - Ambulatory Care ClinicSubmittal #: Submittal Spec #:230548.001-2 Preparer ApprovalSellen Approval Spec SectionSub SectionRevision A. Approved as noted for A/E Review 2305482B. Revise & Resubmit C. Rejected Seismic & Vibration Control Mechanical Penthouse Equipment This review is for general conformance with the plans and specifications only. Any deviations from same not clearly noted by the subcontractor have not been Resubmittal to address Sparling reviewed. Review shall not constitute a complete check or detailed dimensions comments (attached) or count or serve to relieve the subcontractor of contractual responsibility for any error or deviation from contract requirements. Prepared By: Sellen Construction Jason Petterson HermansonBy: Scott SolbergDate: 04/13/15 Architect ApprovalEngineer / Consultant Approval Submittal Review Swedish Edmonds ACCApril 28, 2015 Project:Date: of 1 1 Page: Barb Gipple - NBBJ Architect: Scott Solberg - HermansonAdam Bettcher Contractor:Reviewed by: NO EXCEPTIONS TAKEN REJECTED MAKE CORRECTIONS NOTED SUBMIT SPECIFIED ITEMS REVISE AND RESUBMIT SUBMITTAL NOT REQUIRED & NOT REVIEWED This review is only for general conformance with the design concept of the project and general compliance with the information given in the contract documents. Corrections or comments made during this review do not relieve contractor from compliance with the requirements of the drawings and specifications and do not authorize changes to contract cost. Contractor is responsible for: Dimensions which shall be confirmed and correlated at the job site; fabrication process and techniques of construction; coordination of his work with that of all other trades; performing his work in a safe manner. Sparling has reviewed the copy of the Submittal 135-230548001-2 received electronically on April 14, 2015, and our comments are as follows. (Note: All of our review comments are contained in this document. There are no markups on any of the information sheets submitted.) Section 230548 – Vibration and Seismic Controls for Mechanical Piping and Equipment 1.The submittal contains revisions to 135-230548-001 that were requested by Sparling in the response to submittal 135-230548001-2; the thickness the neoprene isolator located beneath the spring for the chiller is now called out. We take no exceptions to this submittal. Maureen Jackson – Sparling cc ab:filename 4100 194th St SW • Suite 400, Lynnwood, Washington 98036-4613 206-667-0555 800-667-0610 Fax: 206-667-0554 www.sparling.com 230548-001.1 Seismic for Penthouse Equipment 4/10/15 REVISION OTHERMATERIALS,COMPOUNDS,ORFINISHESWITHEQUALORSUPERIOR PROPRIETARY:EXCEPTASOTHERWISEAGREEDINWRITING,THEINFORMATIONANDDESIGNDISCLOSEDHEREINARETHEPROPERTYOFTHEVMCGROUPANDMUSTNOTBECOPIEDORDISTRIBUTEDOUTSIDETHEVMCGROUPEXCEPTTOAUTHORIZEDPERSONSWITHAGENUINENEE DTOKNOW PROPERTIESMAYBESUBSTITUTEDASTHEYBECOMEAVAILABLE. NONE 1OF1 DRAWINGNO.: SCALE: SHEET: --- THEVMCGROUP Bloomingdale,NJ07403 ThePowerofTogether Houston,TX77041 .75 .15 .10.05 4 3 MAXI-FLEXPAD WHOBYTHEUSEHEREOFACKNOWLEDGETHEVMCGROUP'SOWNERSHIPANDAGREETOMAINTAINTHISINFORMATIONANDDESIGNINSTRICTCONFIDENCE. 4 3 18 Edmonds 18 105444 Swedish CERTIFIEDFOR: --- --- CUSTOMERP.O.: SALESORDER: CUSTOMER: JOBNAME: Mar 26, 2015 Submittal Review Swedish Edmonds ACCMarch 17, 2015 Project:Date: of 1 1 Page: Andris Lapins - NBBJ Architect: Scott Solberg - SellenAdam Bettcher Contractor:Reviewed by: NO EXCEPTIONS TAKEN REJECTED MAKE CORRECTIONS NOTED SUBMIT SPECIFIED ITEMS REVISE AND RESUBMIT SUBMITTAL NOT REQUIRED & NOT REVIEWED This review is only for general conformance with the design concept of the project and general compliance with the information given in the contract documents. Corrections or comments made during this review do not relieve contractor from compliance with the requirements of the drawings and specifications and do not authorize changes to contract cost. Contractor is responsible for: Dimensions which shall be confirmed and correlated at the job site; fabrication process and techniques of construction; coordination of his work with that of all other trades; performing his work in a safe manner. Sparling has reviewed the copy of submittal 135-230548001-1 – Seismic and Vibration for Mechanical Equipment received electronically on March 3, 2015, and our comments are as follows. (Note: All of our review comments are contained in this document. There are no markups on any of the information sheets submitted.) This submittal is a revision of the previous vibration isolation submittal. Sparling requested that the submittal be revised and resubmitted due to discrepancies between the spec and the submittal for the S-3 spring isolator that was located on the chiller. Specifically, a neoprene pad needed to be inserted between the spring and the plate, along with a loading distribution mechanism. The revised submittal (Revision 3, the most recent revision from VMC) places ‘Custom MS-2E vibration isolators with integral seismic restraint with Maxi-Flex Pads for 2” deflection’ on the chillers. These pads replace the original neoprene cup of the spring with VMC “Gray” elastomeric pads set beneath a metal plate. The submittal does not appear to specify the thickness or shape of the Maxi-Flex Pads pads, which should be ¾” to 1” thick. Please submit information on this product, such as specific cutsheets, and specify the thickness. Maureen Jackson – Sparling cc hb:B17787\\SR 230548.001 4100 194th St SW • Suite 400, Lynnwood, Washington 98036-4613 206-667-0555 800-667-0610 Fax: 206-667-0554 www.sparling.com