Loading...
Complete_moreinfor_PLN20160046.pdfIIle. 189" October 18, 2016 CITY OF EDMONDS 121 5th Avenue North, Edmonds WA 98020 Phone: 425.771.0220 • Fax: 425.771.0221 • Web: www etlm nils ra.ov DEVELOPMENT SERVICES DEPARTMENT • PLANNING DIVISION Katie Wagner Michaela Lahurreau Estate 7726 — 236"' Street SW Edmonds, WA 98026 Subject: Letter of Completeness and Request of Additional Information Michaela Lahurreau Estate 2 -Lot Short Subdivision Application Number PLN20160046 Ms. Wagner, On behalf of the City of Edmonds Planning Division, I have reviewed the application for a 2 -lot short subdivision at 7726 — 236th Street SW for completeness pursuant to Edmonds Community Development Code (ECDC) 20.02.002 and 20.75.040. The City has determined that the application meets the procedural submission requirements and therefore is complete. Please accept this letter as the City's notice to applicant of determination of completeness pursuant to ECDC 20.02.003. While the application is procedurally complete, additional information and clarifications are needed for continued review of the application. Please respond to the following so review of this application can proceed: 1?lant icl ; I1,v slon Cc mrt c at : Lot area. The subject property is located with the RS -8 zone which requires a minimum lot area of 8,000 square feet. As noted in ECDC 21.55.020, lot area excludes any street rights-of-way or access easements. The preliminary short plat shows net lot area of Lot 1 at 7,200 square feet after the access easement has been excluded from lot area. As a result Lot 1 as shown on the preliminary short plat does not comply with the minimum lot area required by ECDC 16.20.030 for the RS -8 zone. Please revise the proposed short plat so both lots comply with the minimum lot standards as detailed in ECDC 16.20.030. 2. Setbacks. Setbacks are not shown correct on either of the proposed lots. Lot 1 will be a corner lot with street setbacks from 781h Avenue W and 236th Street SW. Side setbacks are measure from the southern property line and the edge of the access easement for Lot 2 along the east side of Lot 1. The preliminary short plat does not show the 7.5 -foot side setback from the access easement. Lot 2 will have street setbacks from 78th Ave W, rear setback from the eastern property boundary , side setback from the northern property boundary and side setback from the access easement along the southern property boundary. The preliminary short plat shows all side setbacks for Lot 2. Please revise the preliminary short plat to correctly show all setbacks as described above in accordance with ECDC 16.20.030. 3. Coverage. Coverage calculations are based on the net lot area. While Lot 1 will have to be redesigned to comply with the zoning requirements, the coverage on the preliminary short plat would not be compliant with the zoning requirements. Also please not coverage is not the total square footage of the proposed or existing residence, rather it is the foot print of the building. ECDC 21.15.110 defines coverage as: Coverage means the total ground coverage of all buildings or structures on a site measured from the outside of external walls or supporting members or from a point two and one-half feet in from the outside edge of a cantilevered roof, whichever covers the greatest area. When the preliminary short plat is redesigned please calculate coverage consistent with ECDC 21.15.110. 4. Easements. A utility easement is shown across the southern portion of Lot 2, but this also appears to be an access easement established with the subdivision recorded under AFN 8603130288. The title report also identifies two other easements (AFN 7611230189 and AFN 8603030287) that are not shown on the preliminary short plat. Please show and label all easements encumbering the property on the preliminary plat map. 5. Trees. Please identify any tree removal that will be necessary to install improvements associated with the short plat. 6. Shed. There is a shed on Lot 2 that is approximately 1 foot from the property line with 78'" Avenue W. The shed should be removed to be brought into conformance with the setback standards for the RS -8 zone. The shed may stay on the same location if it can be shown that the shed is a legal nonconforming structure. Documentation can be in the form a building permit approval for the shed or photographic or other substantial evidence that conclusively demonstrates that the shed existed on or before January 1, 1981 in accordance with ECDC 17.40.020.A. 1 n it ;w �°ira 1 iv i a� Comments: 7. The subject development will be required to widen half of 78th Ave W to provide for an 11 -foot wide travel lane. Revise plan to show the street widening. 8. In accordance with Edmonds Community Development Code (ECDC) Chapter 18.90 and the City of Edmonds Sidewalk Comprehensive Plan map, sidewalks are required as a condition of subdivision approval along both 78th Ave W and 236th St SW. Revise plans to show construction of curb, gutter, sidewalk, and intersection curb ramp. Please take into consideration the following: a. Utility conflicts, with specific attention to 78th & 236th intersection (power pole and fire hydrant). Relocation may be required. b. Please identify tree removal associated with the required improvements. 9. The sidewalk impervious surface area shall be accounted for in the stormwater management design. The project will have over 5000sf of impervious surface area and the system must therefore be designed by a licensed engineer. Please submit a preliminary storm drainage report. 10. An existing 20 -foot utility easement has been identified along the south property line. The City has a utility easement (AFN 7611230189), but there also appears to be an access easement through this area. Provide recording numbers for all easement encumbering the subject property. 11. The fence shown within the City right-of-way will need to be removed or relocated to private property. Page 2 of 3 12. Sheet 2 — Revise impervious surface area chart to include non-regulated areas. Also, please clarify what surface (1980sf) is being identified as replaced regulated. 13. Sheet 2 - Show all existing and proposed dry utilities and easement areas as required. 14. Sheet 2 - Label limits of new driveway surface in plan view. According to ECDC 20.02.003.1), the above requested information must be submitted within 90 days (or by January 16, 2017) or the application will expire. Since the application has been determined to be complete, a notice of application will be posted on the subject property and mailed to adjacent property owners within the next two weeks consistent with ECDC 20.03.002. If you have any questions of me, please contact me at 425-771-0220 or via email at lcernen 1Lje9:1,cr�eddrl?cv. ' i 4'rely, einien Lien Senior Planner Cc: Jeanie McConnell, Engineering Program Manager Page 3 of 3