Loading...
Daley St-808_pln20080006_Lybeck_2 lot SP.pdf Daley St-808_pln20080006_Lybeck_2 lot SP CITY OF EDMONDS ENGINEERING REQUIREMENTS FOR SHORT PLATS Name:Lybeck - 2-lot short platFile No.: PLN20080006 Reviewed by:Address: Jeanie McConnellApril 14, 2008808 Daley Street Engineering DivisionDate Required as a Required as a Requirement Condition of Condition of Already SFR Building SubdivisionSatisfied Permit Right-of Way Dedication for Public Streets: 1. a)N/A 2.Public Street Improvements (Asphalt, curb, gutter and sidewalks): a)Sidewalk construction waiver granted. b) Asphalt widening required on Daley Street. The south edge of Daley Street shall be widened to within 2 feet of the public fire hydrant and X shall extend from approximately the west property line, to the east edge of Lot 1 driveway and/or turnaround. 3.Private Access Requirements & Improvements: Provide asphalt or concrete driveway approach to Lot 1. a) X Slope of driveways shall not exceed 14% and shall be noted as such b). X on the civils. 4.Street Turnaround: On site turnaround is not required. Daley Street shall be improved so a) as to provide for sufficient turnaround to the east of the driveway X approach. Easements 5. (City utilities, private access, other utilities): a) X Provide all easements as required. 6.Street Lights: N/A a) 7.Planting Strip: N/A a) 8.Water System Improvements (OVWSD): Provide new water service to Lot 1 a) X Connect to public water system. b)X X 9.Sanitary Sewer System Improvements (OVWSD): Provide new 6" service lateral from City's sanitary sewer main to Lot 1 b) X with 6" cleanout at property line. Provide new 4" side sewer to Lot 1. X c) Connect to public sewer system. d)X X 1 of 2 Daley St-808_pln20080006_Lybeck_2 lot SP Required as a Required as a Requirement Condition of Condition of Already SFR Building SubdivisionSatisfied Permit 10.Storm Sewer System Improvements: Provide a Stormwater Management report and plan. Compliance with a) ECDC 18.30 and 1992 Department of Ecology Stormwater Manual is X required. Construct privately owned and maintained storm detention system b) sized to provide adequate capacity for proposed single family dwellings, associated impervious areas and street improvements in X accordance with ECDC 18.30. Storm detention system to be located on private property. Connect all new impervious surfaces to detention system. c)X X Provide storm sewer stub to Lot 1. d) X Connect to public storm system. X e) X 11.Underground Wiring (per Ord. 1387): Required for all new services. a)X X 12.Excavation and Grading (per IBC) Submit a grading plan as part of engineered site plan. a)X X Submit grading plan for foundations with building permit. b)X 13.Signage (per City Engineer): N/A a) 14.Survey Monumentation (per Ord., Sect. 12.10.120): N/A a) 15.As-built Drawings (per City Engineer): Required for all street and utility improvements. Provide an AutoCAD a) X X electronic copy and a hard copy to City. 16.Other Requirements: Plat showing lots, easements, legals, survey information a)X X Legal documents for each lot b) X Field stake lot corners (by professional surveyor) c) X Field stake utility stubs at property lines d) X Clustered mailbox location per Postmaster e) X Maintenance agreements f) X Traffic Impact Analysis g) X 17.Engineering Fees: Storm development charge (access tract)N/A a) Storm system development charge$428.00 b)X Sewer connection fee $730.00 c)X Water connection fee $908.00 d)X Water meter fee - 3/4" meter $550.00 e)X Traffic mitigation fee$840.72 X f) Short Plat review fee $860.00 g) X Inspection fee (2.2% of improvement costs)TBD h) X Date Engineering Program Manager, CITY OF EDMONDS 2 of 2