DOH review approval letter.pdf Letter of Transmittal August 13, 2015 Construction Review Services 111 Israel Rd. SE Tumwater, WA 98501 PO Box 47852 Olympia, Washington 98504-7852 Address Plans To (internal use only): Rosewood Courte Memory Care Community www.doh.wa.gov/crs Attn: Facility Administrator tel. 360-236-2944 728 Edmonds Way fax. 360-236-2321 Edmonds, WA 98020-5126 Project Info: CRS# 60548773 Project 728 Edmonds Way Rosewood Courte Memory Care Community location: Edmonds, WA 98020 Chapter 388-78A WAC Assisted Living Facility Add Nurse Office and Apartment Local Permit #: BLD20150594 Key People: Assigned DOH Kevin A. Scarlett, RA Reviewer: kevin.scarlett@doh.wa.gov Facility Rosewood Courte Memory Care Community Facility Contact: Same as Administrator Administrator: Patrick Shepard 728 Edmonds Way Edmonds, WA 98020-5126 (425) 673-2875 x. x. patrick@rosewoodcourte.com Architect / Robert Moore Architect Local AHJ: City of Edmonds Engineer: Robert Moore Leif Bjorback th 106 Madison Ave N 121 5 Ave N. Bainbridge Island, WA 98110 Edmonds, WA 98020 (206) 371-5191 x. (425) 771-0220 x. rmoore@robertmoorearch.com bjorback@ci.edmonds.wa.us Consultant: N/A Consultant: N/A x. x. Contact: N/A Contact: N/A x. x. Copies To: of Edmonds DOH Child Birth Center Licensing Local AHJ: City DOH Office of Investigations & Inspections Moore Architect Architect / Engineer: Robert L&I Electrical Section /A Consultant: N L&I Factory Assembled Structures /A Consultant: N /A Contact: N CRS File /A Contact: N Page 1 of 7 Plan Review Comments for Project #60548773 Facility Data Certificate: Facility Name: Rosewood Courte Memory Care Community Licensee UBI#: 601926961 Site Address: 728 Edmonds Way Critical Access Facility: Yes No Edmonds, WA 98020 Estimated Date of Occupancy: Currently Occupied Occupancy Construction Applicable Code: R2 Group: Type: 2012 IBC Number of Current: 43 Added: 2 Removed: 0 Total: 45 Beds: Automatic Fire Sprinkler System: Yes No Type Automatic Fire Alarm System: Yes No Compartmentation req’d: Yes No Smoke Control System Provided: Yes No Special Delayed Egress Control: Yes No Location: Certificate of Need Required: Yes No CON Approval Granted: Yes No CON Number : Number of units: Private occupancy: Two person occupancy: Based on size of rooms used for sleeping Residents Based on size of common rooms Residents Maximum allowable licensable beds: Qualifies for Assisted Living Funding Program Yes No Number of qualifying units: Put up wall to create office. Convert common area to an apartment. The data above is based on the information presented to CRS. Any change in the facility or facility program that causes the above information to be incorrect is subject to review by CRS. Approval for construction is not approval for licensure. A copy of the facility data certificate will be sent to the licensing agency. Page 2 of 7 Plan Review Comments for Project # 60548773 Rosewood Courte Memory Care Community Chapter 388-78A WAC Assisted Living Facility Add Nurse Office and Apartment : Project Status - Authorized to Begin Construction - - All Comments Approved – The construction documents have been reviewed and found acceptable. Construction can begin, subject to construction permitting from the local building official. Project Close-out Requirements Once the below have been completed, we will notify Department of Social & Health Services (DSHS) that you have completed the review process and are ready for final inspection Please note the following: The stamped “Authorization to Begin Construction” drawings will be delivered to the Facility Administrator. These shall be kept available on site for inspection during construction and at post occupancy survey. Final licensing approval is subject to a site inspection by DSHS and the Office of the State Fire Marshal to verify compliance with licensing regulations and your approved documents. If stamped approved plans are not available, the site inspection may be terminated until such time they are available as determined by the licensing inspector/surveyor. Any changes/deviations (incl. change orders or addenda) from the stamped documents must be submitted to the Department for review and approval. Please include your CRS number on all communications to Construction Review Services. PROJECT CLOSE-OUT REQUIREMENTS You must notify the department when construction is complete by completing the following steps: Verify that you have resolved all of the comments on this form and have submitted any revisions Complete the Notification of Construction Completed at: http://www.doh.wa.gov/NotificationofCompletion.aspx Email a copy of the approval from the local building department (final permit approval or fslcrs@doh.wa.gov certificate of occupancy) to: fslcrs@doh.wa.gov Email a floor plan showing the scope of work to: If you have any questions please contact Construction Review Services at (360) 236-2944. You can monitor project status at www.doh.wa.gov/crs. Page 3 of 7 Plan Review Comments for Project # 60548773 Rosewood Courte Memory Care Community Chapter 388-78A WAC Assisted Living Facility Add Nurse Office and Apartment Plan Review Comments: 1 Indicate (on plan) where existing Fire Alarm Detection and Notification Devices are located for both work locations. Approved 6/24/15 – based on documents received 5-28-15. –kas 2 Indicate (on plan) where existing Fire Sprinkler heads are located for both work locations. Approved 6/24/15 – based on documents received 5-28-15. –kas 3 Provide a City of Edmonds Building Permit number for this work. Approved 6/24/15 – based on documents received 5-28-15. –kas 4 Indicate what the new office space used to be used for. Approved 6/24/15 – based on documents received 5-28-15. –kas 5 Indicate the type of new doors and their construction details (20min, SCWD, vision panel in 47, listed closers and locksets, etc). Not Approved 6/24/15 – based on documents received 5-28-15, this comment is approved except for the following; Door 67 must be 20min rated (otherwise this comment is approved. Also, both 20 min. doors 67 & 68 must positively latch (via auto closers) when door is released from full open position. –kas Approved 7/24/15 – based on documents received 7-16-15, Door 67 shall be 20 min rated (see attached revised door schedule dated 7-14-15). Doors 67 & 68 each have (2) spring hinges per submittal dated May 26, 2015 for positive latching. -kas 6 Indicate what wall infill at door construction materials are used (stud spacing, GWB size & type, etc). Approved 6/24/15 – based on documents received 5-28-15. –kas 7 Indicate what wall, floor & ceiling finishes will be used, patched, installed new. Approved 6/24/15 – based on documents received 5-28-15. –kas Page 4 of 7 Plan Review Comments for Project # 60548773 Rosewood Courte Memory Care Community Chapter 388-78A WAC Assisted Living Facility Add Nurse Office and Apartment 8 Indicate what heating & cooling devices will be provided for the new 2 bedroom apartment and where the thermostat is located. Not Approved 6/24/15 – based on documents received 5-28-15, this comment is approved except for the following; these wall heaters need to shown to mount as high as possible (suggest contacting product mfr for distance from ceiling requirements) to avoid burning these special Memory Care residents. The Paw-guard option may still be necessary. Consult with the Facility Administrator and the manufacturer, then contact your CRS reviewer with the results of those discussions prior to proceeding with this issue. Also, indicate the finished ceiling height in this bedroom. -kas Approved 7/24/15 – based on documents received 7-16-15, in lieu of the King wall heaters specified 5-26-15 we would like to instead use the Ouellet ORC Sunshine Radiant Cove Heaters which can be installed on the wall 4.5” down from the ceiling (see attached spec sheets). One (1) 450watt heater in each sleeping area as shown on plan. Ceilings are 8 feet high. -kas 9 Provide catalog cuts for all new door hardware. Approved 6/24/15 – based on documents received 5-28-15. –kas 10 Indicate where common space is located for the use of the Memory Care residents in this West wing (corner). Not Approved 6/24/15 – based on documents received 5-28-15, CRS reviewer is consulting with DSHS directly, however, Lobby 50 does not meet the requirements of WAC 388-78A-3050. Contact your CRS reviewer to discuss, what, if any, options exist for compliance with this regulation. -kas Approved 7/24/15 – based on documents received 7-16-15, the entire facility is memory care and residents can move freely throughout the building. -kas 11 Indicate what corridor wall ratings are intended. Approved 6/24/15 – based on documents received 5-28-15. –kas 12 Indicate what is provided and intended for window types at existing and new windows in this project (fixed, sliders, size of openings, screens, etc). Not Approved 6/24/15 – based on documents received 5-28-15, Architect to verify that at least one window in the apartment meets requirements of 2012 IBC 1029.2 & 1029.3 -kas Page 5 of 7 Plan Review Comments for Project # 60548773 Rosewood Courte Memory Care Community Chapter 388-78A WAC Assisted Living Facility Add Nurse Office and Apartment Approved 7/24/15 – based on documents received 7-16-15, the existing “E” windows noted on the plan drawing are single hung 3-0 wide x 5-0 tall windows – these meet the 5.7 square foot net clear opening requirement. The openings are also located within the 44” maximum distance to the floor. -kas 13 Indicate what room furnishings and accessories will be provided in the new resident room to fully comply with WAC 388-78A (2 towel bars, 2 wardrobes of what size, the correct number of electrical outlets, etc). Approved 6/24/15 – based on documents received 5-28-15. Refer to added comments 17 & 18 below. –kas 14 Indicate where Nurse Call devices are located. Approved 6/24/15 – based on documents received 5-28-15. –kas 15 Provide ventilation to comply with 2012 IMC outdoor air requirements. Approved 6/24/15 – based on documents received 5-28-15. –kas 16 Indicate how you will separate work areas from other residents and maintain work areas with a negative pressure space. Also, do not allow dust/ debris to enter existing exhaust and/or return air ducts. Approved 6/24/15 – based on documents received 5-28-15. –kas 17 Indicate where secure (lockable) storage for each resident is located (indicate how the location/unit complies with WAC 388-78A-3010(1)(i) Approved 7/24/15 – based on documents received 7-16-15, each resident shall have a night stand with a lockable drawer meeting the requirements of WAC 388-78A- 3010(1)(i). -kas 18 Indicate where additional storage for each resident is located (indicate how the location/unit complies with WAC 388-78A-3010(1)(j) Approved 7/24/15 – based on documents received 7-16-15, each resident shall have a wardrobe for adequate storage of clothing and personal possessions per WAC 388-78A-3010(1)(j). -kas 19 Patrick Shepard requested the following in an email dated 7/6/15; The wall & door separating the corridor (and this small renovation) from the rest of the community appears to be smoke/fire door. We would if possible like to do away with this door. Page 6 of 7 Plan Review Comments for Project # 60548773 Rosewood Courte Memory Care Community Chapter 388-78A WAC Assisted Living Facility Add Nurse Office and Apartment Approved 7/24/15 – This door IS NOT a Fire or Smoke door, nor is the adjacent wall. This door and cross-corridor wall may be removed. –kas 20 N/A Contact CRS Senior Plans Reviewer Kevin A. Scarlett at 360.236.2949 to schedule a Final Inspection within 2 weeks of completing construction efforts. Compliance with the comments above provided by the Department of Health, Construction Review Services, are necessary for this facility to meet the requirements of the applicable licensing regulations found in the Washington State Administrative Code and associated references. These comments do not relieve the facility from the responsibility to meet the requirements of any other applicable federal, state or local regulations. In the event of conflicts between other jurisdictions and these written comments, the most stringent shall apply. Page 7 of 7 Plan Review Comments for Project # 60548773