DRC2014-002 Martin ShortSub.doc
MEMORANDUM
Date:September 17, 2014
To:Perry Martin
From:Fire Marshal John J. Westfall 425.771.0213
th
Subject:DRC2014-002 Short Subdivision 23402 75 Ave W
This Review is conducted in accordance with 2012 IFC and Edmonds Community Development
Code. Fire Services provide the following comments:
1. Existing fire hydrants meet spacing requirements. ECDC 19.25.055 C.
2. For construction: a residential fire sprinkler systems will be required when dwelling living
space (fire area) exceeds 3,000 s.f., including covered porches and patios over 4’ wide.
A flow-through design is recommended. ECDC 19.05.020 C.
3. When a sprinkler is required, provide minimum combination water-service of one inch
(1”) meter and one and one half inch (1 ½ ”) service line for each property; or show that
domestic and fire protection needs, when required, can be met with smaller service.
General Facility Charges are based upon domestic requirements only. For instance, up-
sizing to one inch (1”) meter will be calculated to fees for a three quarter inch (3/4”)
connection. Equipment will be charged by actual equipment costs.
I will not be attending your Development Review Meeting (DRC), however, feel free to call if you
have further questions.
City of Edmonds Office of Fire Marshal