EdmondsDerm1.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: September 18, 2007 TO: Brian Pollestad BP Contracting FAX: 425-788-3545 FROM: Ann Bullis, Assistant Building Official RE: Plan Check # 2007-0882 Project: Edmonds Derm – Tenant Improvement th Project Address: 21701 76 Ave W During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Provide written responses to each comment and where changes can be found on the plans. Please resubmit revised plans to Theresa Umbaugh, Permit Coordinator. 1.On the coversheet: a.Note that the Type of Construction is VA. b.Revised code information to 2006 editions. st 2.Clearly label the floor plans on Sheet A101 that work is on the 1 floor of the building. 3.On the floor plans, label the existing 1-hour fire rated corridor, including self-closing 20 minute rated doors. Also clearly note that new door 114C will be self-closing, 20 minute rated with “S” label. 4.Show locations of illuminated exit signage and emergency lighting, and note method of power backup. 5.Relabel Corridor 111 as hallway, unless the architect intends it to be a true 1-hour rated corridor and meet requirements of IBC 1017. 6.Provide 1-hour rated wall construction detail at new corridor wall. It must extend to the existing 1-hour rated floor-ceiling assembly above. Cross-reference the detail on the floor plans. 7.Dimension width of the accessible portion of the reception counter to show compliance with ICC/ANSI A117.1 Section 904. 8.Provide/dimension accessible maneuvering distances at doors 104, 112, 123, and tenant space side of main corridor doors. ICC/ANSI A117.1 Section 404.2.3 9.Revise door schedule to note that door hardware must meet exiting requirements and be accessible (such as lever-style). 10.Provide typical wall construction detail, including stud type/size/spacing, thickness of sheetrock, top and bottom anchoring, etc. If you intend 3/A105 to be the typical wall detail, please revise to include this information. 11.The alterations require accessibility upgrades per IBC/WAC 3409.6. On the plans clearly show that the exterior and interior accessible route of travel complies with current code, or provide upgrades per the previously referenced section. If you choose to use exception #1 of that section, provide a letter stamped and signed by the architect (reference the code exception), stating what parts of the existing site/building/tenant space are not accessible, the project cost and what 20% of it equals, list the upgrades that will be done as part of this permit as well as showing that the total cost of the upgrades is at least 20%.