Loading...
Email to Applicant with Engineering Comments.pdf Machuga, Jen From:Machuga, Jen Sent:Friday, May 12, 2017 5:37 PM To:'jack.tricoland@frontier.com' Subject:RE: Request for Additional Information for Johnson Short Plat Application (PLN20170020) Attachments:PLN20170020 Prelim-Engr Memo 1.pdf HiJack, nd InadditiontotherequestforadditionalinformationIemailedtoyouonMay2,pleaseseetheattachedrequestfor informationfromtheEngineeringDivision(datedApril24,2017).Whenpreparingaresponsetobothrequestsfor additionalinformation,itwouldbehelpfulifyouprovideacoverletterstatinghoweachcommenthasbeenaddressed. Pleasecontactmewithanyquestions. Thankyou, Jen Jennifer Machuga, Associate Planner City of Edmonds, Planning Division 121 - 5th Avenue North Edmonds, WA 98020 (425) 771-0220 ext. 1224 Jen.Machuga@edmondswa.gov Development Services Hours: Monday & Tuesday 8:00 AM – 4:30 PM Wednesday 8:30 AM – Noon Thursday & Friday 8:00 AM – 4:30 PM From: Machuga, Jen Sent: Tuesday, May 02, 2017 5:29 PM To:jack.tricoland@frontier.com Subject: Request for Additional Information for Johnson Short Plat Application (PLN20170020) HiJack, PleaseseetheattachedrequestforadditionalinformationregardingtheJohnsonshortplatapplicationat8498Talbot Rd.(FileNo.PLN20170020).Thehandoutsreferencedintheattachedletterareavailableforreferenceviathefollowing links: P2ΑInstructionsonHowtoCompileandAdjacentPropertyOwners(APO)List E28ΑEdmondsUtilitiesConsortiumContactForm Feelfreetocontactmewithanyquestions. Sincerely, Jen 1 Jennifer Machuga, Associate Planner City of Edmonds, Planning Division 121 - 5th Avenue North Edmonds, WA 98020 (425) 771-0220 ext. 1224 Jen.Machuga@edmondswa.gov Development Services Hours: Monday & Tuesday 8:00 AM – 4:30 PM Wednesday 8:30 AM – Noon Thursday & Friday 8:00 AM – 4:30 PM 2 MEMORANDUM Date: April 24, 2017 To: Jen Machuga,Associate Planner From: JoAnne Zulauf, Engineering Technician Subject: PLN20170020,Johnson 2 -lot short plat 8498 Talbot Road The comments provided below are based upon review of the preliminary civil plans & documents for the subject short plat. Additional informationis requested from the applicant at this time in order to continue review of the application and provide preliminary approval of the short plat. Please ask the applicant to providea written response to each of the outstanding comments below and revise and resubmit plans accordingly. Please also note, after receiving preliminary short plat approval from the Planning Division, the applicant will be required to submit civil engineering plans to the City for review and approval after receiving preliminary short plat approval from the Planning Division. To confirm feasibility of a new lot, the plans need to show that it is buildable. The plan should have a proposed house outline, driveway, storm system, and utilitiesfrom the main to the house with inverts to confirmcode requirements can be met. GENERAL 1.Please add outline of house, garageand drivewayfrom edge of paved road to the house. Note the square footage of each.The square footage of the house/garage should include eves. 2.Call out slope of driveway. The Edmonds Community Development Code does not allow for driveway slopes to exceed 14% without first obtaining approval by the City Engineer. The maximum allowed drivewayslope is 20%. Adjust the slope of the driveway to reflect a 14% grade and/or maximum 20% grade along with a request for waiver that provides an . A request for waiver explanation as to why the required 14% slope cannot be achieved requires noticing per aType II decision. City of Edmonds UTILITIES 1.Please submit a stormwater report including full infiltration calculations (see the city’s Stormwater Addendum to determine the specific testing requirements. Please ensure the stormwater management design for the proposed single family lot is reflectiveof the eve line of the house, driveway, and any patios, walkways, etc.Show a stormwater mitigation system on the plans based on the infiltration rate and the infeasibility checklists. If there will be an outfall, show what it connects to and where. Provide approximateinverts for all connections to confirm feasibility. 2.Sewer and water services should be shown from the main to the house. Provide approximateinverts for the sewer connection to the main and at the house to confirm minimum 2% slope is possible. 3.Show the location of stormwater systems, sanitary sewer systems, water mains and water service lines adjacent to or within the proposed subdivision.Provide approximate invert elevations for side sewer at house, property line and new connection to main to show feasibility. Call out length and size of all pipe to verify slopes. Thank you.