Eng Comments #5.doc
City of Edmonds
TH
121 5 AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221
Website: www.ci.edmonds.wa.us
DEVELOPMENT SERVICES DEPARTMENT
Planning • Building • Engineering
Plan Review Corrections
Plan Check : Date:
# 2008-0123 July 29, 2008
Project Name/Address:
Jeffries/19018 Sound View Pl
Contact Person/Address/Fax:
Ben Jeffries 19018 Sound View Pl Edmonds, WA 98020
ND
Reviewer: JoAnne ZulaufDivision:Engineering (2 Sending)
During review of the subject submittal, it was found that the following information, corrections, or
clarifications would need to be addressed. Our handouts can be found online at the City of
Edmonds web site www.ci.edmonds.wa.us under City Government/Development
Services/Engineering Division.
Please note that site plan and drainage plan must match. May note on site plan “see drainage plan” for
the drainage details, cb invert #s etc. but basic info should be on all plans.
1.6/26/08 Impervious surface calculations on site plan do not match new calculations submitted on
drainage plans. Please revise site plan.
Provide a thorough breakdown of the existing and proposed impervious surface on the site plan, for example;
Existing Impervious: Roof outline: xxxxx Year built: xxxx
Driveway: xxxx xxxx
Decks: xxxx xxxx
Total: xxxxx
Proposed Impervious: Roof outline: xxxx
Deck: xxx
Walkway: xxx
Total: xxx
2.
06/26/08 Site plan still shows storm drain line to be used, please revise site plan to show changes
submitted on drainage plan for storm drainage (at least “to be abandon or removed” and “see drainage
plan”)
It is not permitted to build structures over a city storm drain line. In order to build in the location indicated
by the submitted plans, the storm drain pipe will need to be rerouted around the west side of the new
structure. It will be required that a new utility easement be granted the City of Edmonds to access pipe for
DATE MAILED/FAXED 6/29/2017 PAGE ____ OF ___
12
maintenance and repair. Please submit a site plan showing a proposed route with all relevant invert and rim
elevations, structures, ditch lines, etc. for review.
3.06/26/08 Your drainage report is being reviewed by our Storm Water Engineering Consultant.
4.
06/26/08 Done.
5..
06/26/08 Done
6.
06/26/08 Done.
7.
06/26/08 A 6” clean out with locking 12” cast iron lamphole cover is required at the property line and a
6 – 4” clean out is required at the house for the side sewer. Please add a note to plans “existing side
sewer lateral will be TV’d by Public Works to determine if in good working condition for reuse”
8.06/26/08 Not Done. Clearly label all areas on site plan. For example, it is difficult to tell if the area
between the garage and driveway is pavement/concrete area or something else.
9.06/26/08 Not Done. If removing concrete area, walk, driveway, and stairs near existing house, please
label “to be removed”.
10.06/26/08 Done.
11.06/26/08 Not Done. Existing fence and gate shown on site plan are in the right of way. Please remove
from right of way or apply for Encroachment Permit. Handout E#26 explains requirements for
Encroachment permit application. This handout can be found on our website following the instructions
above.
12.06/26/08 Not Done. Please indicate that existing access from Water St. will be removed with demolition
of existing house after new construction complete.
13.
06/26/08 Done.
14.06/26/08 New Comment: Show on all plans new proposed driveway access from Water St to
garage in rear of new home. Add impervious surface to impervious surface calculations.
Please resubmit 3 copies of the revised plans/documents to a Development Services Coordinator.
Please contact me at 425-771-0220 if you have specific questions regarding these plan corrections.
DATE MAILED/FAXED 6/29/2017 PAGE ____ OF ___
22