MEMORANDUM
Date:
July 7, 2011
To:
Gina Coccia, Planner
From:
Jennifer Lambert, Engineer Technician
Subject:
PLN20110044,ADB –15,120 SF Pre-Fabricated Modular
th
21605–76Ave W
Engineering has reviewed and approved the subject application withthe following
comments/conditions to be noted in the staff report.
Compliance with Engineering codes and construction standards will be reviewed with the
building permit application for development of the site.
In addition please note the following mayhave an impact on the layout:
The size of the proposed raingarden may or may not be adequate. If the
raingarden needs to be resized additional parking stalls may need to be
removed.
Raingardens collecting runoff from areas greater than 5000 sqft shallbe
located away fromthe structure such that it does notintersect with the 1H:1V
slope from the bottom edge of the raingarden. The minimum separation from
the raingarden and a structure is 5’ or aminimum of 10’ ifthe structure has a
basement.
Proposed utility location. Without drainage reports, rim and invert locations,
etc. it is not possible to determine if the proposed utility locations will allow
the systems to function properly.
Thank you.