Loading...
Eng_Comments_1,7-7-11.pdf MEMORANDUM Date: July 7, 2011 To: Gina Coccia, Planner From: Jennifer Lambert, Engineer Technician Subject: PLN20110044,ADB –15,120 SF Pre-Fabricated Modular th 21605–76Ave W Engineering has reviewed and approved the subject application withthe following comments/conditions to be noted in the staff report. Compliance with Engineering codes and construction standards will be reviewed with the building permit application for development of the site. In addition please note the following mayhave an impact on the layout: The size of the proposed raingarden may or may not be adequate. If the raingarden needs to be resized additional parking stalls may need to be removed. Raingardens collecting runoff from areas greater than 5000 sqft shallbe located away fromthe structure such that it does notintersect with the 1H:1V slope from the bottom edge of the raingarden. The minimum separation from the raingarden and a structure is 5’ or aminimum of 10’ ifthe structure has a basement. Proposed utility location. Without drainage reports, rim and invert locations, etc. it is not possible to determine if the proposed utility locations will allow the systems to function properly. Thank you. City of Edmonds