City of Edmonds ENG20090156
TH
121 5 AVENUE NORTH EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221
Website: www.ci.edmonds.wa.us
PUBLIC WORK DEPARTMENT
Planning • Building • Engineering
Engineering Plan Review Comments
Permit Application :Date:
# ENG20090156 6/4/09
th
Project Name/Address:
21616 – 76 Ave W
Contact Person/Address, Fax or E-mail:
Ron Sacco & Evelyn Chase – evelyn@conneldesign.com
Reviewer: JENNIFER COLLINS Division:
ENGINEERING
During review of the subject submittal, it was found that the following information, corrections, or
clarifications would need to be addressed. All Handouts referred to in these comments can be accessed at
our website: www.ci.edmonds.wa.us under City Government / Development Services Department /
Engineering Division then scroll down to Handouts:
1.Please revise the civil drawings and the architectuals so that they match.
a.The layout of the driveway approach and width of the driveway differ between plans.
2.State on the plans which erosion control methods will be applied to the project. At a minimum,
standard detail E1.3, catch basin protection, is required.
3.Please clarify the drainage of the new driveway.
a.It appears that very little, if any, surface water runoff will actually be collected in the
trench drain.
4.Show that the radius of the driveway approach are adequate for the turn radius of the delivery
vehicle on the plans and please provide the calculations for this determination.
5.Please show on the plans that curb will be painted yellow 5’ beyond the west end of the driveway
and restriping existing yellow curb section as needed.
6.Please show on the plans an adequate driveway approach where the east wing will still allow for
ADA standards to be met when transitioning from the walkway to the sidewalk.
SOME OPTIONS
a.Install the driveway approach per Edmonds Standard Detail E2.26. Readjust the
walkway so that walkway does not tie into the driveway approach wing, but onto the
sidewalk.
b.Install the driveway approach consistent with the attached detail. Widening the
sidewalk behind the driveway entrance by a minimum of 2’ to allow for a 5’ sidewalk,
with max 2% cross slope, to be maintained.
In both of the options provided above the existing hand rail will need to be removed or
redisgned.
DATE E-MAILED 6/4/09 PAGE()
1
City of Edmonds ENG20090156
TH
121 5 AVENUE NORTH EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221
Website: www.ci.edmonds.wa.us
PUBLIC WORK DEPARTMENT
Planning • Building • Engineering
Engineering Plan Review Comments
c.If you have another solution please resubmit and we will review for approval. Please
keep in mind that the maximum riveway slope is 14%.
Please resubmit 3 copies of the revised traffic control plans and associated documents with a written
response to each item to an Engineering Technician. Please contact me at 425-771-0220 ext 1321 or by e-
mail at collinsj@ci.edmonds.wa.us if you have specific questions regarding these plan corrections.
DATE E-MAILED 6/4/09 PAGE()
2