Loading...
eng20110259_104_ST_SW-24111_ROW-PSE.pdf City of EdmondsENG20110259 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments PermitApplication:Date: #ENG2011 0259November 10, 2011 th Project Name/Address: 2411–104Ave W –WO#109063925 Contact Person/Address, Fax or E-mail: Kelli Martin Reviewer: JENNIFER LAMBERTDivision: ENGINEERING During review of the subject submittal, it was found that the following information, corrections, or clarifications would need to be addressed. All Handouts referred to in these comments can be accessed at our website: www.ci.edmonds.wa.usunder City Government / Development Services Department / Engineering Division then scroll down to Handouts: General 1.Please provide approval from Olympic View Water Sewer District (OVWSD) for the proposed work. 2.Please add a note to the plans that if the cuts extend beyond the centerline of the road a fullwidth grind and overlay will be required. Sheet 3 of 8 th 1.The city storm main extends north of 104than what is shown (approximately to the middle of 23615 th 104Ave W). Please revise plans accordingly. th 2.It appears that a portion of the proposed gas main along 104Ave W will be replaced within the sidewalk. a.Please show all cuts within the sidewalk and/or asphalt. b.Please note what material will be replaced (i.e. sidewalk panel,asphalt roadway, etc). c.Please show that 5’ separation will be maintained between the proposed gas and the City Storm Main. Sheet 5 of 8 1.The city has a future Stormwater project that is proposed to run conveyance and infiltration lines along th the north side (within the shoulder) of 238St SW. DATE E-MAILED11/10/2011PAGE(1) City of EdmondsENG20110259 TH 121 5AVENUE NORTHEDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORK DEPARTMENT Planning • Building • Engineering Engineering Plan Review Comments a.Please show the new line as close tothe aphalt edge or within the roadway; such that the proposed line meets OVWSD requirements as well as maintain 5’ separation from the City Stormwater Main. b.Please show any asphalt cuts on the plans. If there are significant cuts within the roadway, please note that ‘A ½ width grind and overlay may be required’. st 2.Please note on the plans that a ‘A ½ width grind and overlay will be required on 101Ave W’. Sheet 6 of 8 1.Please note on the plans that a ‘A ½ width grind and overlay will be required on Firdale Ave W’. th 2.If the cuts on 238St SW are within the asphalt walkway, please note on the plans that, ‘The walkway th will be replaced from Firdale Ave W to the limits of construction on 238St SW’. th 3.If the cuts on 238St SW are not within the asphalt walkway, please note as such on the plans. Sheet 7 of 8 1.Please note on the plans that a ‘A ½ width grind and overlay will be required on Firdale Ave W’. Sheet 8 of 8 1.Please note on the plans that a ‘A ½ width grind and overlay will be required on Firdale Ave W and rd 243Pl SW’. ***Please make sure that any changes made above are also reflected on the appropriate Traffic Control Plans. *** Please resubmit 3 copies of the revised traffic control plansand associated documents with a written response to each item to an Engineering Technician. Please contact me at 425-771-0220ext 1321or by e- mail at jennifer.lambert@ci.edmonds.wa.usif you have specific questions regarding these plan corrections. DATE E-MAILED11/10/2011PAGE(1)