eng20140039-water main-civil-E1.docx CITY OF EDMONDS PLAN REVIEW COMMENTS ENGINEERING DIVISION (425) 771-0220 City Website: www.edmondswa.gov DATE: February 18, 2014 TO: Wade Watkinson, KPFF FROM: JoAnne Zulauf, Engineering Technician RE: Application #: eng20140039 Project: Water Main th Project Address: 21601 76 Ave W During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please submit three (3) sets of revised plans/documents with a written response to each of the items below to a permit coordinator. City of Edmonds handouts, standard details and development code can be referenced on the City website. All the work on this project is considered “Right of Way” improvements because it is located within the right of way or within City easements. If you want to keep the separation of the right of way from the work within the property, it would be acceptable to rename the column “Private Improvements” to read “Public Easement Improvements”. Please revise the Bond Quantity Worksheet as follows: Page 2: a.Please add temporary fencing to delineate construction areas. b.Plastic covering for stockpiles will be necessary for this project. c.Add a minimum of 15 hrs for a tesc supervisor d.Please add three additional catch basin inlet protections. e.A minimum of 15 hrs should be estimated for the water truck dust control. Page 3: a.Quantities for Backfill and Compaction do not appear to reflect the 415 lf of pipe with width and depth of trench. Please revise the excavation bulk quantities. b.Excavation-see a. Page 4: th a.Please see the attached map showing the required extent of pavement replacement on 76 Ave W. Please revise quantities for AC removal to reflect the additional quantity. b.Add 20lf of extruded curb. c.Please add sealant lineal footage for all trenches. d.Sidewalk replaced in the right of way shall be 5” thick. Please revise from 4” thick. e.Add additional square footage for striping the crosswalks, stop lines, etc. added with the extended overlay requirements. eng20140039-water main-civil-E1 Page 1 of 2 Page 5: th a.AC road measure for 76 Ave W shall be for 5” road thickness. Also revise to reflect additional overlay areas. Page 6: a.Please add the two bollards to be located at the fire hydrant on site. Page 8: th a.Two curb ramps will be disturbed on 76 Ave W. Please add cost to “Write in Items”. Please make any additional changes necessary due to further plan revisions. Page 2 of 2