Loading...
eng20140093- Carlson.pdf City of Edmonds TH 121 5AVENUE NORTH •EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineering Plan Review Comments Plan Check :Date: #ENG20140093February25, 2014 Project Name/Address: Carlson Residence Driveway-646 Alder Street Contact Person/Address/Fax: Max Schmidt max@quercuslandscape.com Reviewer:Chris RiveraDivision:Engineering During review of the subject submittal,it was found that the following information, corrections, or clarifications wouldneed to be addressed. All Handouts referred to in these comments can be accessedat our website: www.ci.edmonds.wa.usunder City Government / Development Services Department / Engineering Division then scroll down to Handouts: 1)Please add a note thatfilter socks will be added as needed per Edmonds Standard Detail E1.3. 2)Please add a note that all disturbed soils will be compost amended. 3)Driveway approach and wheel paths should shift further east to give more clearance from the homeand gas meter. 4)The new driveway approachwill count towards total new impervious surface area. Please provide total sqft for new ramp.Please provide total proposed impervious calculations. 5)Please add notethatcurb will be replaced as calledoutin handout E2.26.Please show on site plan areas of the curb/gutter tobe replaced for the new driveway approach. 6)Please show on plans the 2’ asphalt cut and patch adjacent to curb/gutterto be replaced. Handout E2.26. 7)If the concrete entry walkway is poured in the same foot print as existing it will not be counted as new impervious surface. Please note on planswhether you are replacingexistingconcrete or adding new impervious. 8)Please clarifyif pavers are intended to work as a pervious or impervious surface. If pavers are intended to be installed as a pervious surface pleaserefer to the Permeable Pavement Systems Flow Chart (Figure 1) of the Permable Pavement Policyto make sure project meets requirements. If requirements are meet, install according to handout E72B,Low Impact Development (LID) Storm Water Best Management Practices (BMP).If pavers are intended to be animpervious surface, install according to manufacturer’s requirements. DATE FAXED/E-MAILED2/25/2014PAGE __1__ OF __1_ 9)Please show on site plan sqft of all existing impervious surfacesand provide year of construction. Please provide total calculations forallproposed impervious surfaces and existingimpervious surfaceon the plans. i.e. walkways, gravel areas, patios, roof, etc. 10)From the Site Classification Worksheet (page 5of Handout E72 , attached), please provide a copy of the completedtable. Please resubmit 3 copies of the revised plans/documents.Please contact me at 425-771-0220 if you have specific questions regarding these plan corrections. DATE FAXED/E-MAILED2/25/2014PAGE __1__ OF __1_