Loading...
ENG20160119-APPROVED PERMIT.pdfTY OF EDMONDS 121 5TH AVENUE NORTH; EDMONDS, WA 98020 tn� 181 PHONE: (425) 771-0220 - FAX: (425) 771-0221 *PERNUT`MUST BE POSTED ON JOBS TE* STATUS: ISSUED ENG20160119 RIGHT OF WAY PERMIT (6-EUC) Permit Number: ENG20160119 Expiration Date: 12/29/2017 Job Address: 7600 212TH ST SW, EDMONDS Location: 76th and 212th Frontier Communications PACIFIC CABLE Attn: Shelley Haugstad 11321 HWY 99 S#10 180041st Street Everett, WA 98201 *Revision of original permit* Audits ofe)dsting cables are required, this is preliminary workto be,completed for City of Edmonds intersection improvement project. Workproposed is in ebsting vault east ofthe intersection. DISRUPTION INFORMATION ASSESSED VALUE: $0,00 PROPERTY AREA° 0 SIDEWALK: (OXO) DURATION IN MONTHS:0 FEE: $0;,00 STREET DISRUPTION TRENCH CUT: ( 0 X 0 PARKING. (,OXO) DURATION IN MONTHS: 0 FEE $0,00 YEAR OF OVERLAY: 0 FEE $0,,00 ALLEY: ( OXO) DURATION IN MONTHS: 0 FEE: $0,00 INDEMNITY The Applicant has signed an application ivhich states he/she holds the City of Edmonds harmless from injuries, damages or claims ofany kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any ofils departments or employees, including but not limited to the defense ofany legal proceedings including defense costs and attorney fees'by reason ofgranting this permit. THE CONTRACTOR IS RESPONSIBLE FOR WORKMANSHIP' AND MATERIALS FOR A PERIOD OFONEYEAR FOLLOWING THE FINAL INSPECTION AND ACCEPTANCE OFTHEWORK 0 Traffic Control and public safety shall be in accordance with City regulations.. as required by the City Engineer. Every flagger must be trained as required by (WAC) 296-155-305 and must have certification verifying completion of the required training in their possesion. « Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. • Three sets of construction drawings of proposed work are required with the permit application. CALL DIALrA-DIG (1-800-424-5555) BEFORE ANY EXCAVATION CALL FOR INSPECTION (425) 771-0220 "?EXT. 1326 24 HOUR NOTICE1tEQUIRED FOR ALL INSPECTION REQUESTS SIGNED BY RELEASED SPACE PROVIDED Printed: W 513/2-17 DATE ❑ FILE COPY ❑ INS PECTOR COPY ❑ APPLICANT COPY 20 • Restore ROW to City standards •= RestoreLandscape to like or better conditions. • Call for locates of underground utilities prior to any excavation. • Alert affected residents and/or businesses prior to work start, • Conform to approved working drawings and Traffic Control plan. • Utility patch restoration to be in accordance with Edmonds Standard detail E2.3' • Maintain erosion & sedimentation control. Keep street clean. • Call for required inspections as noted. • Traffic Control per approved plan and MUTCD. Refer to City of Edmonds traffic control requirements. • This permit is only approval for work within the right of way. Work on private properties will need approval from property owners. • Applicant shall repair/replace all damage to utilities or frontage improvements' in City right-of-way per City standards that is caused by or occurs during the permitted project. • Sound/Noise originating fromtemporary construction sites as a result' of construction activity are exempt fromthe noise limits of ECC Chapter, 5.30 only during the hours of 7:00amto 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites /activities must comply With the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. • Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the issuance of this pen -nit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance not limit in any way the City's ability to enforce any ordinance provision. • &Traffic Control • E Engineering Final PARTIAL INSPECTION DATE: INITIAL: NOTES: PARTIAL INSPECTION' DATE: 1NITI! A LNOTE FINAL INSPECTION APPROVED DATE:" INITIAL: CUSTOMER: FRONTIER CONTACT. Dow Brandley 425-263-5101 LOCATION: 76th Ave W & 212th St SW Edmonds WA 04/19/17 5122710 1. Designed By: Robert Pratt WSTCS#010077 K A 0 G E t yia eu ORTCS#06162 1'WAtlrrmo 1AANA1M,4rW, off: 503-729-7287 Ext 1013 Cell 0 603539-0548 'hr 9C__PA"_0t :RYIG01 11% PLEASE SCHEDULE WITH DISPATCH @ 800-343-4049 OP11 AND PROVIDE A COPY OF THE APPROVED TRAFFIC CONTROL PLAN K&D Services, as the preparer of this traffic control plan makes no representation as to its' general adequacy or being approved for implementation. Approval must result from the Traffic Engineer or other Public Official having statutory enforcement authority in the jurisdiction. Utilization and implementation of this plan shall be a result of that approval. Ref. MUTCD 2009 SA-.P_t 10 n. .................... 1 I 3 1 1 1 1 I t is+ I fly h N Lane Width 10' P t AQ d 30 q" Notes: 1. Maintain ped. access to and through crosswalks 2. Maintain Min. 10' lanes 3. Maintain local access 4. Notify Transit Authority at least 48 hrs. in advance of bus stop closure 5. Traffic control plan and all devices shall comply with MUTCD, PROWAG & WSDOT 6. DEVICE SPACING Flag Taper 20' Signs per WSDOT Tapers per WSDOT 7. 28" Cones 36" Barrels 48" Signs 24" Paddle 8. Adjust to field conditions INVENTORY: I 3 -ROAD WORK AHEAD 1 -RIGHT LANE CLOSED AHEAD' 1 -TRANSITION LEFT 30 -CONES RStA os a pee Merge Taper 150' Buffer 75' ��t4())Df> �'A',IV�,,�����.... Sign Spacing (X) 200'+l- Devices Taper 20' �w + �+ +N `�,Spotters to guide pedestrians Devices Tangent 40' � ,,,,?/through work area safely W err tlr�nr + t .JAIS NMED Legend i i t _. Illllllllli ® Work Area • Cone Bucket truck '�'' Spotter road work ahead W20-1 Right lane closed ahead OW -122 II road narrows W4-2 Spotters to guide pedestrians through work area safely 150' Merge Taper 200"' YA YNIy! � �IPOY 200"flg o ro sc,a� NO I , ,FIRE AND POLICE 72 HOURS IN ADVANCE