ENG20170397-APPROVED PERMIT.pdf_ Ot,- ELl'i' to 1
ROW PERMIT NO.: ENG
ISSUE DATE:
]1 R GTHT-OF-WAY CC01\4S I<'RUCT IOlN
P ERMRT APPLIICATRON
PROJECT DAME: 106329554
CONTRACTOR: PSE/Infrasource
Mailing Address: 1660 Park Lane Burlington Wa 98233
CONTACT: Susan Sidick
Pliolle #: 425-457-6353
Fax #:
State License #: INFRASL871C2 Email #: susan.sidick@pse.com
City Business License #: NR-023614 ❑ Liability Insurance ❑ Bonded
AIDIDRESS OR INTERSECTION OF CONSTRUCTION: 18719 94th AVE W
ROW WORK ASSOCIATED WITH THE FOLLOWING TYPE OF PROJECT: ,
❑ Commercial ❑ Subdivision ❑ City Project ❑ Traffic Control (Only)
❑ Multi -Family ❑ Single Family ❑ Other
❑ EUC (PUD, VERIZON, PSE,
COMCAST, OVWSD):
Is this permit pact of a blanket perinit? ❑ Yes ❑ No
ANY ASSOCIATED PERMITS? 131,D# ENO#
DESCRIPTION OF PROPOSED WORK(Be Specific),: Work area is approx 150' S c/l of
187th ST SW & 12' W & 8' E c/1 of 94th AVE W to install gas service 1 3x5 & 1 2x4 paving cut
anticipated.
WAS STREET OVERLAYED WITHIN THE LAST FIVE 5) YEARS? YES ❑ NO ❑ Year:
PAVEMENT CUT: Yes ❑ No If yes, indicate size of cut: 3 x 5
CONCRETE CUT: ❑ Yes ❑ No If yes, indicate size of cut: x
RIGHT-OF-WAY
CLOSURE
AREA
TOTAL
DURATION
(NUMBER OF MONTHS)
Sidewalk 48 Iles +
LF
X
LF
SF
Alley 72 Ilrs +
LF
X
LF
SF
Parking 72 Hrs +
LF
X
I L,FJ
SF
APPLICANT TO READ AND SIGN
*Traffic control and public safety shall be in accordance with City regulations as required by the City
Engineer. Every flagger must be trained as required by (WAC) 296-155-305 and must have certification
verifying completion of the required training in their possession.
*Restoration is to be in accordance with City codes and Standards. All street -cut trench work shall be
patched with asphalt or City approved material prior to the end of the workday — NO EXCEPTIONS.
Indemnity: The Applicant has sighed an application which states he/she hold the City of
Edmonds harmless from injuries, damages or claims of any kind or description
whatsoever, foreseen or unforeseen, that may he made against the City of Edmonds or
any of its departments or employees, including defense costs and attorney fees by reason
of granting this permit.
I have read the above statements and understand the permit requirements and acknowledge that I must
follow all requirements in order for the permit to be valid.
SIGNATURE HATE 10/06/2017
Contractor or Agent
NO WORTS SHALL, BEGIN PRIOR TO PERMIT ISSUANCE
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 008997
Card Exp. 08/13/2019
gregory.harwood@pse.com
(425)424-642
0
yG
l•-OZM
p Y �
� ¢ Od3Hl
o ovoa
'1 3NVI 3N
I
I
I
14 114
I
14 14
Q
LEGEND
®
28" TRAFFIC CONE
®
BORE PIT
TRAFFIC FLOW
FLAGGER
WORK VEHICLE
SIGN LOCATION
WARNING FLAG
CHANNELIZATION
DEVICE SPACING
MPH
TAPER
TANGENT
55/70
40
80
35/45
30
60
25/30
20
40
PUGET
' SOUND
ENERGY
Job#106329554
18719 94th Ave W, Edmonds, WA
September 15, 2017
Sheet 1 of 2 brent.pogson@pse.com
(425) 398-6158
Notes:
1. All signs and spacing to conform to the MUTCD
and City of Edmonds standards.
2. All sidewalks, driveways, exits and egresses shall be
completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
4. Sign size can be a minimum of 48" x 48" and shall not
obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for traveling
lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m.
8. Work area will be 12' WCL of 94th Ave W &
approximately 232' SCL of 187th St SW.
9. If used, place NO -PARK signs 72 hours in advance
of the day that the work is to be done.
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 008997
Card Exp. 08/13/2019
gregory.harwood@pse.com
(425)424-642
PUGET
SOUND
ENERGY
Job#106329554
18719 94th Ave W, Edmonds, WA
September 15, 2017
Sheet 2 of 2 brent.pogson@pse.com
(425) 398-6158
\ �y
yG 6-0
o ovoa
�ad�dMeMo.
LEGEND
®
28" TRAFFIC CONE
®
BORE PIT
TRAFFIC FLOW
FLAGGER
WORK VEHICLE
SIGN LOCATION
WARNING FLAG
CHANNELIZATION
DEVICE SPACING
MPH
TAPER
TANGENT
55/70
40
80
35/45
30
60
25/30
20
40
� a
b ---- co ------
Notes:
1. All signs and spacing to conform to the MUTCD
and City of Edmonds standards.
2. All sidewalks, driveways, exits and egresses shall be
completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
4. Sign size can be a minimum of 48" x 48" and shall not
obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for traveling
lane width.
6. Alert affected residents and businesses.
7. Work to take place between 9 a.m. and 4 p.m.
8. Work area will be 8' ECL of 94th Ave W & approximately
232' SCL of 187th St SW.
9. If used, place NO -PARK signs 72 hours in advance
of the day that the work is to be done.
Job #:
106329554
Date:
9/5/17
Jurisdiction:
Edmonds
Right of Way Permit?
❑� YES ❑ NO
Est. Start Date:
10/09/17
Est. Duration:
8 HOURS
PRE -INSPECTION REPORT ®PUGETSOUND ENERGY
Address: 18719 94TH AVE W
City / Zip: EDMONDS 98020
Customer: GAIL GIFFORD 425-223-6805
CUST PHONE NUMBER
PM / Insp: Kiara Hays 425-213-9205
PHONE NUMBER
WORK DESCRIPTION:
INSTALL 40' OFI-1/8"PESCATSTUBAND 38' OFI-1/8"PESCATEXT. SETA425M5A
OIL 14T6IN WC.
Construction Method
Open Trench ❑
Trenchless ❑
PLAT
MAP: 160 067
G 3: CL W
rnl
u;
rn
v~i
I
El
I
I I
I
I I
� I
PL
187TH ST SW
S
I
1
I
I
1
I
0=
Fire Hydrant (165' S OF TIE IN)
00
V
l0
I
1
1
I
I
LLI I
Q 1
2 S
H
01
I
I I
I
I I
I
G CL W
PL
7
Work Location
Size of Cut
Surface Type
150 f CL
187TH ST
W &_2— W f CL 94TH AVE W
3X5
ASPHALT
150 - 9,Sb f CL
187TH ST
SW & 8 'E
of CL 94TH AVE W
2X4
ASPHALT
'N S of CL
& 'E W of CL
❑
❑
FLAGGERS #
OFFICERS #
MPH
SPEED LIMIT
❑ TROLLY LINES ❑ BUS STOP #
❑ TRAFFIC SIGNAL ❑ ARTERIAL
❑ METER HOODS #
❑ NO PARKS #
❑
0
❑Multi
❑
❑
❑
❑�
Commercial ❑
Residential ❑
-Family
y ❑
New Constr. ❑
Stub ❑
Extension ❑
Compete Sery ❑
Altered Commercial ❑ Leak Repair
Altered Residential ❑ CP Work
Replacement Service ❑ Pothole
Main Maintenance ❑ Extension
Service Maintenance
valve Maintenance
Cut & Cap
Service Information
Diameter Meter
❑ 5/8" ❑ 250
11/8" 425
❑ 11/4" ❑ 630
❑ 2" ❑ 1000
Mtr Loc: O/L
❑ Template Bar
EFV ❑
❑ 1800 Bollards 2.5" #
❑ 2600 ❑Bollards 4" #
❑ 10,000 ❑ FUEL LINE PERMIT NEEDED
Fuel Line Length:
Fuel Line Diameter:
18624
18626
5/8" PE
��4f 1993
18702
118716
18 704
5/8' WE
1995
18730
t 'Y83PE IN T -
7s
238E
ti
2395
e,
No electric grid information available
S160062, Q160067
10-05-2017
hC M7l son w raammms Mee$ is uAWC11001@rQQ N"%M NfCQ. aonM"ra
Tw WlOpit, O•t6 MbT'C�O�•G•C/1r C10ot4 �OC�±�On1C'{Yi Op�70 �01 CILOCO TSCdri00'�7d 1n�T1'a01100�v chOt UG=I jecs
yroec ama+sa in,•ns� b; R+Cw Seu�d 6+arp;. Mc n'+cC �s no11e eo woo b oploTrinp Tw ee4 a �ooOtOn o•en; SSE +xnaoc Kd fi : i
2•'STW IP 1
6696-1964
Y�
1 /T STW-U
1968
18701
SME
5/8" WE
2002
18 723
u
1 1/8" MPE IP 270S 130'E
107013151-2002
5/8" PE
1993
9232
9228
5/9' MPE
2002
3t
2"ST W IP 21'N Tb
6696-1964
187TH ST S
1 I 18732
Scale 1:722 +
Lat\Long=47.8291,-122.3585
9224
5/8" PE
1991
US* PE
1994
18730
92
Q PUGET SOUND ENERGY
, &—%W 1Y e
I lov
-low
0 u
>
W
I
rh