ENG-Comment-1.pdfof Ell-'Vo CITY OF EDMONDS PLAN REVIEW COMMENTS 4�3"'A ENGINEERING DIVISION .(425) 771-0220 City Website: www.edmondswa.gov DATE: December 31, 2019 TO: Heidi Helgeson heidi@h2darchitects.com FROM: Jennifer Lambert, Engineering Technician Jennifer.lambert@edmondswa.gov RE: Application 9: BLD20191533 Project: Murphy - Demo Project Address: 406 2nd Ave N During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please submit revised plans/documents including a written response to each item below. Resubmittals can be made at the Development Services Department on the 2nd floor of City Hall. Permit Center hours are M, T, Th & F from 8am-4:30pm and on Wednesdays from 8:30am-noon. City of Edmonds handouts, standard details, application and other forms, and development code may be referenced on the City website: www.edmondswa.gov under Services/Permits and Development. GENERAL 1) A right-of-way permit is required to perform work within the City right-of-way (ROW). A ROW Permit Application shall be completed by the contractor and submitted to the City prior to issuance of the building permit. 2) If any easements exist, please show all information within the plan sets. Note AFN's for existing easements and/or recording documents for proposed easements as applicable. 3) Show haul routes. Truck and trailer will not be permitted. 4) This demo plan sheet should show only the existing features (no proposed features). However, show the proposed foundation line of the proposed structure if the sewer is not being cut and capped at the property line (see note 5b below). 5) Show the sewer being cut and capped. a. If the side sewer (from the property line to the house) is not proposed to be re -used, show the sewer being cut and capped at the property line. b. If the existing side sewer is proposed to be re -used, the line must be cut and capped a minimum of 20' from existing and/or proposed foundation, whichever is closest to the property line. 6) Show the existing water service line being disconnected at the meter and the installation of a hose bib with an AVB at the meter. 7) Show existing utilities on the plans 8) The project is located within the downtown area. Please show and/or describe the haul route. TESC 1) Show filter fence location on the plans and incorporate and reference City standard detail ER-900. 2) Show the construction entrance on the plans and incorporate and reference City standard detail ER-901. 3) Please show and add a note to the plans that filter socks will be added to any catch basins downstream from the construction site. Incorporate and reference City standard detail ER- 902. 4) Orange protective barrier fencing shall be placed at the drip line of trees to remain and around areas proposed for low impact development techniques, such as rain gardens, infiltration systems, etc., to protect the area from compaction. 5) Please provide the location of the temporary stockpile. Add a note that the stockpile is to be covered within 24 hours. 6) Add note: All disturbed areas to be compost amended per 2014 SWMMWW BMP T.5.13. 7) Add note: Install and maintain all TESC measures according to approved plans, City of Edmonds standard details, and all other measures that may be required during construction. Page 2 of 2