Loading...
ENGINEER RESPONSE TO ENG.pdfcivil & structural R ESUB ENGINEERING engineering &planning i �„ ��F. � 4 2015 c ull�DIN DWARWONT EW (IF EO 08 December 3, 2015 Jennifer Lambert City of Edmonds 1215th Avenue N Edmonds, WA 98020 RE: Permit Application #BLD20151238 Engineering Plan Review Project Name: Hendrickson Residence Project Address: 410 2nd Avenue N Dear Ms. Lambert, Itemized below is our response to the November 30, 2015 review comments submitted for the above referenced project. Our response appears in bold. C1.1- COVER SHEET AND GENERAL NOTES 1. Please reference the building permit on the plans (BLD20151238). Permit number referenced. C2.1- TEMPORARY EROSION CONTROL PLAN 1. There are trees along 2nd Ave that are not noted to remain. a. If these trees are to remain the silt fence should be located at the drip line of the tree to protect the tree roots. Please revise the plans accordingly. Silt fence adjusted as noted. 2. If there are tree from the adjacent properties where the drip line extends onto the subject site, please show the trees and their drip lines from the adjacent sites. There are not drip lines from adjacent sites. 3. Please show protection fencing at the drip line of the trees. Fencing added as noted. 4. The existing concrete driveway could be used as a construction entrance as long as no vehicles will drive off of the concrete area. Add a note/revise plans if needed. Note added to plans. 5. Please add a note to the plans that state the existing utilities will be removed and/or capped under the demolition permit (BLD20151239). Note added to plans. 250 4th Avenue South, Suite 200 Edmonds, WA 98020 ph. 425.778.8500 1 f. 425.778.5536 www.cgengineering.com Hendrickson Residence 15193.20 Civil Comment Response 6. Please show the grading and grading calculations on this plan sheet. Grading contours, spot elevations, and quantity calculations added to sheet. 7. Show the proposed and existing topographic lines on this plan sheet. Existing and proposed topography shown. 8. Revise the title of this plan sheet to include grading. Revised as noted. C3.1—GRADING AND UTILITY PLAN GENERAL 1. Please remove the grading from this plan sheet and put it on the C2.1. December 2, 2015 Page 2 of 3 Grading is still depicted on this sheet to show sloping to drains, cover over pipe, etc. It has been added to C2.1 as requested. 2. Please remove grading from the title. Removed. 3. Add a note to the plans that if the existing sidewalk is damaged and/or does not meet current ADA standards the sidewalk will need to be replace. Note added. WATER 1. Please add a note that the meter box is to be replace and the meter is to be raised. Note added to meter callout. SEWER 1. Per the plans there appear to be trees planted over the City sewer main. Please provide a description of what trees are located on or near the sewer main. Callouts from survey added to plans. There is a 10" holly, 8" deciduous, and a 6" deciduous over or near the main. 2. The side sewer is shown to go through an existing tree that is stated to remain. Is the tree to remain? If so, please show the sewer line located outside of the drip line of the tree. Side sewer relocated as noted to avoid tree. 250 4th Avenue South, Suite 200 Edmonds, WA 98020 � --- ph. 425.778.8500 1 f. 425.778.5536 ENGINEERING www.cgengineering.com Hendrickson Residence 15193.20 Civil Comment Response December 2, 2015 Page 3 of 3 It is unclear from the plans if the proposed side sewer is existing and proposed is to be reused. If the sewer is proposed to be reused, the sewer will need to be inspected by the City's Public Works department to determine if it can be reused. Contact Edmonds sewer division, 425-771-0235. a. If the sewer cannot be reused, anew connection will be required. The connection at the main will need to be a romac inserta tee installed by the contractor (not the City of Edmonds). New connection is provided. Inserta Tee note added. 4. Please add a note that the cleanout located at the edge of easement is a 6" cleanout and will have a 12" cast iron lamphole cover with %" hexbolts. Cleanout note added. 5. Show a cleanout located within 2' of the structure. Cleanout added. STORM 1. The proposed detention system is located within the drip line of the tree. If this tree is to remain, the detention system must be located outside of the drip line of the tree. Please revise the plans accordingly. Detention system rotated out of drip line. 2. Please show where the footing drains will discharge to. Please note that the footing drains cannot discharge into the detention system unless it is designed to collect for groundwater. Revise the plans accordingly. Footing drain shown connecting to outfall of detention system. 3. Add a note to the plans that the roof drains located under the driveway must have a minimum of 2' of cover. Note added. If you have any questions or comments regarding the responses to this review please do not hesitate to call. Sincerely, CG Engineering GreGuil n, PE, SE Prin 250 4th Avenue South, Suite 200 Edmonds, WA 98020 ----- ph. 425.778.8500 1 f. 425.778.5536 �,� www.cgengineering.com