Loading...
Engineering Comments 1 - Revised.pdfof ED,Vo CITY OF EDMONDS N PLAN REVIEW COMMENTS ., ENGINEERING DIVISION 14'sr. , s9° (425) 771-0220 City Website: www.edmondswa.gov DATE: October 25, 2018 REVISED November 5, 2018 TO: Janet Elene J_elene@hotmail.com FROM: Natalie Griggs, Engineering Technician Natalie.griggs@edmondswa.gov RE: Application 4: BLD20181288 Project: New ADU Project Address: 7901 206d' St SW During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please submit revised plans/documents including a written response to each item below. Resubmittals can be made at the Development Services Department on the 2nd floor of City Hall. Permit Center hours are M, T, Th & F from 8am-4:30pm and on Wednesdays from 8:30am-noon. City of Edmonds handouts, new updated standard details with new reference numbers, application and other forms, and development code may be referenced on the City website: www.edmondswa.gov under Services/Permits and Development. SITE PLAN 1) The new impervious surface area associated with the proposed ADU appears to be incorrect. Please also add the area proposed to connect the existing residence to the proposed ADU to the total new impervious surface area. 2) The water line shown from the existing water meter ends to the east of the existing asphalt driveway. Show the entire water line to the existing residence on the plans. 3) There is an incomplete side sewer line shown from the west side of the existing residence that crosses in front of the residence and terminates directly east of the existing asphalt driveway. This incomplete side sewer line is not shown to be connecting to anything. This incomplete side sewer line is called out as a new storm line connecting to existing. Please address this discrepancy in the plans and label connection from either the existing residence to the main line. 4) Temporary erosion control fence is shown surrounding the entire property. Please show the specific location where the filter fence will be utilized on the plans and incorporate and reference City standard detail ER-900. 5) Please add a note to the plans that all disturbed soils will be compost amended per BMP T5.13. 6) Note the existing sewer line and cleanout(s) on the plans. Note which of the sewer lines are existing and which are proposed for the ADU. If a new side sewer line will be installed to connect to the proposed ADU, a cleanout shall be located within 2' of the proposed ADU exterior and shall be no more than I foot below grade (if not brought to final grade). Please show on the plans. 7) November 5, 2018: As described per comments addressed by Planning, three parking spaces shall be required with the addition of the ADU. Please revise the site plan to clearly show where these three parking spaces will be located on site. a. The three parking spaces shall be located on private property. b. The parking spaces shall be a minimum of 8 1/2 feet wide by 16 t/2 feet long. c. Given traffic volume on 206th St SW, an on -site turnaround may be beneficial. Page 2 of 2