Engineering Comments 1.pdfCITY OF EDMONDS PLAN REVIEW COMMENTS ENGINEERING DIVISION (425)771-0220 City Website: www.edmondswa.gov DATE: January 9, 2019 FROM: JoAnne Zulauf, Engineering Technician JoAnne.zulauf@edmondswa.gov RE: Application #: BLD20181652 Project: Wassall - Single Family Residence Project Address: 639 2nd Ave W (formerly 118 Caspers) During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please submit revised plans/documents including a written response to each item below. Resubmittals can be made at the Development Services Department on the 2nd floor of City Hall. Permit Center hours are M, T, Th & F from 8am-4:30pm and on Wednesdays from 8:30am-noon. City of Edmonds handouts, New updated standard details with new reference numbers, application and other forms, and development code may be referenced on the City website: www.edmondswa.gov under Services/Permits and Development. GENERAL 1) Submit ROW Permit Application form 2) Submit Side Sewer Permit Application form 3) Include construction sequence. Refer to sample on City website. 4) The General notes on the plans are an older version. Please add current notes. Refer to sample on City website. Please change the WSDOT/APWA version to the current year. 5) A Stormwater Covenant is required to be recorded against the property based on the proposed stormwater facilities for the project. Please complete the covenant, including notarization and any required exhibits and submit to the city. Ensure the stormwater covenant meets Snohomish County Record Drawing requirements. The document must be complete, but will not be recorded prior to permit issuance. Prior to construction, final location of facilities are to be verified (by field inspection and asbuilt) and then the covenant will be recorded. 6) Show all City utilities that are adjacent to the site, include size and material. 7) Add note to plan: Utility patches shall be combined and full width or half width overlay will be required depending on the extent of disturbance. Where utility patches fall entirely within one travel lane, the overlay shall extend to the centerline of roadway. Where utility patches extend into both travel lanes then a full width overlay is required. FRONTAGE IMPROVMENTS 1) Show the sidewalk along Caspers to be replaced with concrete sidewalk. 2) Four foot transitional concrete sidewalk panels at the end of the new frontage sidewalk are required to adjust between ADA compliant sidewalks and existing conditions. Please add a four ft panel on Caspers extending beyond the property frontage and also on 2nd Ave extending beyond the property frontage. 3) Please add the full WSDOT detail for one directional curb ramps to the plans (it includes all the pertinent notes etc.). Add call out on plan to refer to detail. 4) It appears there is an entry error of the elevation points on the sidewalk along 2nd Ave. At the elevation point 38.62 on the west point of the sidewalk and 38.34 on east side, it results in a cross slope over 5%. Please revise to show the cross slope as 2% or less and check other elevation points for accuracy. 5) Show crosswalk striping in heavy pen weight to indicate it will be repainted with project. WATER 1) As indicated by the Fire Department, a fire sprinkler system is required for this property. Typically if there is an existing water service line from the water main to the meter, the water service line/meter will not be the appropriate size and a new tap will be required. The applicant will be required to pay for the new tap on the main and the new meter. Please revise plans to include the following: a. Please add a note that a 1" meter is to be installed b. Show the water meter located in the right-of-way, such that the back of the meter is on the property line or just behind the sidewalk. c. Please show a 1-1/2" water service line to be installed from the back of the meter to the house (as required for a combination fire and domestic service). d. Please label the pipe material and note tracer wire to be installed on the water service line. 2) Show that there is a minimum of 3' of horizontal separation between the water service and dry utilities (i.e. power, phone, gas, cable, etc.). Currently the gas is too close to the proposed water service line. 3) A minimum of 10' of horizontal separation is required between water and sewer lines. In this case, because the water meter will be replaced the current line can be noted to "cut and cap" and the new service can be shown in a location meeting the separation requirement. 4) Please add a note to the plans that all final restoration shall be completed by the contractor not the City of Edmonds. SEWER 1) Label pipe material and size. The sewer lateral (from the main to the property line shall be 6". Once on private property the sewer may reduce to 4". 2) Label cleanout at the property line as 6" with 12" cast iron lamphole cover with %2" hexbolts. Label size of clean out at house. 3) Provide invert elevations at the main, the cleanout at the property line and at the house so that a minimum 2% slope and minimum 2' pipe coverage can be verified. If the slope of the pipe exceeds 20% the pipe will need to be anchored. 4) If the existing side sewer is to be reused. Please add a note that the existing side sewer will need to be TV'd by the contractor and video must be submitted to the City for review and approval to re -use. Page 2 of 3 5) If the existing sewer lateral (main to property line) is proposed to be reused, the City's Public Works Department will need to TV the lateral to determine if it is acceptable to re- use. Add notes to the plans to contact Edmonds Public Works Sewer Division, 425-771- 0235, to schedule inspection. 6) If a new sewer lateral is proposed and the connection will be core drilled, show the connection at the sewer main per City standards and with a Romac Inserta-tee. If the sewer connection will be cut in, please show a wye to be installed. DRY UTILITIES 1) Show all dry utilities and required utility separation. Please add a note that a minimum of 3' separation is required between the dry utilities (power, gas, phone, cable, etc.) and sewer, water, and storm and 5' from any City main lines. STORMWATER ENGINEER REVIEW Refer to separate plan review comments by City Stormwater Engineer, Zachary Richardson. Please contact Zack directly at 425-771-0220 or by email at zachary.richardson(a edmondswa.i!ov with any specific questions you may have regarding his comments. Page 3 of 3