Engineering Comments 1.pdfof ED40CITY OF EDMONDS
�° PLAN REVIEW COMMENTS
ENGINEERING DIVISION
�sr_ ig90 (425) 771-0220
City Website: www.edmondswa.gov
DATE: September 7, 2018
FROM: JoAnne Zulauf, Engineering Technician
joanne.zulauf@edmondswa.gov
RE: Application #: BLD20181095
Project: Wrigley- Single Family Residence
Project Address: 21423 98th Ave W
During review of the above noted application, it was found that the following information,
corrections, or clarifications are needed. Please submit revised plans/documents including a written
response to each item below.
Resubmittals can be made at the Development Services Department on the 2nd floor of City Hall.
Permit Center hours are M, T, Th & F from 8am-4:30pm and on Wednesdays from 8:30am-noon.
GENERAL
1) Submit ROW Permit Application form
2) Submit Side Sewer Permit Application form
3) A Stormwater Covenant is required to be recorded against the property based on the
proposed stormwater facilities for the project. Please complete the covenant, including
notarization and any required exhibits and submit to the city. Ensure the stormwater
covenant meets Snohomish County Record Drawing requirements. The document must be
complete, but will not be recorded prior to permit issuance. Prior to construction, final
location of facilities are to be verified (by field inspection and asbuilt) and then the covenant
will be recorded.
4) Please add note: "Utility patches shall be combined and full width or half width overlay will
be required depending on the extent of disturbance. Where utility patches fall entirely
within one travel lane, the overlay shall extend to the centerline of roadway. Where utility
patches extend into both travel lanes then a full width overlay is required."
5) Please correct the north driveway note to state "install" instead of "installed".
6) Add top of wall elevation and toe of wall elevation to plans.
TESC
1) Orange protective barrier fencing shall be placed at the drip line of trees to remain.
SEWER
1) Please correct the sewer call out to state "install" instead of "installed".
STORM
1) Provide invert elevations for drain drywell trenches.
STORMWATER ENGINEER REVIEW
Refer to attached plan review comments by City Stormwater Engineer, Zachary Richardson.
Please contact Zack directly at 425-771-0220 or by email at
zachary.richardson(dedmondswa.2ov with any specific questions you may have regarding his
comments.
Page 2 of 2