Engineering Comments 2.pdfof Ell-'Vo CITY OF EDMONDS
PLAN REVIEW COMMENTS
4�3"'A
ENGINEERING DIVISION
.(425) 771-0220
City Website: www.edmondswa.gov
DATE: July 13, 2018
TO: Kelli Martin
thepennitnetwork@gmaii.com
FROM: Jennifer Lambert, Engineering Technician
Jennifer.lambert@edmondswa.gov
RE: Application 4: BLD20180354
Project: James Weis - Single Family Residence
Project Address: 16630 — 74th PI W
During review of the above noted application, it was found that the following information,
corrections, or clarifications are needed. Please submit revised plans/documents including a written
response to each item below.
Resubmittals can be made at the Development Services Department on the 2nd floor of City Hall.
Permit Center hours are M, T, Th & F from 8am-4:30pm and on Wednesdays from 8:30am-noon.
City of Edmonds handouts, standard details, application and other forms, and development code
may be referenced on the City website: www.edmondswa.gov under Services/Permits and
Development.
1st Review — 5/18/18
2nd Review — 7/13/18
GENERAL
1) OK
2) OK
3) OK
4) OK
5) OK
6) This comment was left to refer to as changes are made to the plans. Disruption fees
shall apply to cuts made in streets that have been overlaid within the last 5-years.
Refer to City map to verify status of street and use the calculator in Permit Trax
(ROW permit) to determine specific fee based on the size of the cut and the year in
which it was overlaid. The fee to cut into a street was overlaid within the last year has
a multiplier of 5 times the fee. A street overlaid within the last 2 years has a multiplier
of 4 times the fee, and so forth.
7) This comment was left to refer to as changes are made to the plans. Please make sure
to revise all plans sheets as changes are made.
SITE PLAN
1) OK
2) OK
3) 7/13/18 — Comment was not addressed.
5/18/18 Comment: The City sewer main does not exist as shown. Please show all City
utilities located in 74rh P1 W and 76th Ave W.
GRADING AND TESC PLAN (Sheet C1 of 2)
1) OK
2) OK
3) OK
4) OK
5) 7/13/18 — Comment was not addressed. It appears that there are still portions of the
driveway that exceed 14%. All portions of the driveway need to be 14% or under.
Please keep in mind that if you design at 14%, it creates a situation where the
contractor has no margin for error.
5/18/18 Comment: Consistent with Edmonds Community Development Code 18.80.060,
driveway slopes shall not exceed 14% slope.
a. The contours don't appear to match the spot elevations provided.
b. It appears on the plans the south side of the driveway is almost 30% steep. Please
show how you will maintain a minimum of 12' wide driveway and under 14% slope.
Please note the 14% requirement on the plans.
6) OK
STORMWATER AND UTILITY PLAN (Sheet C2 of 2)
1) OK
2) OK
3) OK
4) OK
5) OK
6) OK
7) OK
8) OK
WATER
1) OK
2) OK
Page 2 of 3
3) OK
CF,WF.R
1) OK
2) OK
3) OK
4) OK
7/13/18 — New Comment
5) Please add a note to the plans that if the sewer cannot be reused, the sewer line will
need to be located outside of the buffer.
6) The City sewer main is not shown correctly on 74te Pl W. Please revise the plans
accordingly.
7) Show the City Force line that exists within 761" Ave W.
DRY UTILITIES
1) No comments at this time. If location of utilities change comments may arise.
STORM
1) OK
2) OK
3) OK
4) OK
STORMWATER ENGINEER REVIEW
See below for additional comments. The previous review comments by City Stormwater
Engineer, Zachary Richardson have been addressed. Please contact Zack directly at 425-771-
0220 or by email at zacharv.richardson(&edmondswa.gov with any specific questions you may
have regarding his comments.
1) The final drain pipe, connecting to the public drainage system, is laid backwards and
will direct right-of-way runoff onto the site. Revise the drainage design so that a
minimum of 0.5% positive slope is achieved.