Engineering Comments 2.pdfof Ell-'Vo CITY OF EDMONDS PLAN REVIEW COMMENTS 4�3"'A ENGINEERING DIVISION .(425) 771-0220 City Website: www.edmondswa.gov DATE: July 13, 2018 TO: Kelli Martin thepennitnetwork@gmaii.com FROM: Jennifer Lambert, Engineering Technician Jennifer.lambert@edmondswa.gov RE: Application 4: BLD20180354 Project: James Weis - Single Family Residence Project Address: 16630 — 74th PI W During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please submit revised plans/documents including a written response to each item below. Resubmittals can be made at the Development Services Department on the 2nd floor of City Hall. Permit Center hours are M, T, Th & F from 8am-4:30pm and on Wednesdays from 8:30am-noon. City of Edmonds handouts, standard details, application and other forms, and development code may be referenced on the City website: www.edmondswa.gov under Services/Permits and Development. 1st Review — 5/18/18 2nd Review — 7/13/18 GENERAL 1) OK 2) OK 3) OK 4) OK 5) OK 6) This comment was left to refer to as changes are made to the plans. Disruption fees shall apply to cuts made in streets that have been overlaid within the last 5-years. Refer to City map to verify status of street and use the calculator in Permit Trax (ROW permit) to determine specific fee based on the size of the cut and the year in which it was overlaid. The fee to cut into a street was overlaid within the last year has a multiplier of 5 times the fee. A street overlaid within the last 2 years has a multiplier of 4 times the fee, and so forth. 7) This comment was left to refer to as changes are made to the plans. Please make sure to revise all plans sheets as changes are made. SITE PLAN 1) OK 2) OK 3) 7/13/18 — Comment was not addressed. 5/18/18 Comment: The City sewer main does not exist as shown. Please show all City utilities located in 74rh P1 W and 76th Ave W. GRADING AND TESC PLAN (Sheet C1 of 2) 1) OK 2) OK 3) OK 4) OK 5) 7/13/18 — Comment was not addressed. It appears that there are still portions of the driveway that exceed 14%. All portions of the driveway need to be 14% or under. Please keep in mind that if you design at 14%, it creates a situation where the contractor has no margin for error. 5/18/18 Comment: Consistent with Edmonds Community Development Code 18.80.060, driveway slopes shall not exceed 14% slope. a. The contours don't appear to match the spot elevations provided. b. It appears on the plans the south side of the driveway is almost 30% steep. Please show how you will maintain a minimum of 12' wide driveway and under 14% slope. Please note the 14% requirement on the plans. 6) OK STORMWATER AND UTILITY PLAN (Sheet C2 of 2) 1) OK 2) OK 3) OK 4) OK 5) OK 6) OK 7) OK 8) OK WATER 1) OK 2) OK Page 2 of 3 3) OK CF,WF.R 1) OK 2) OK 3) OK 4) OK 7/13/18 — New Comment 5) Please add a note to the plans that if the sewer cannot be reused, the sewer line will need to be located outside of the buffer. 6) The City sewer main is not shown correctly on 74te Pl W. Please revise the plans accordingly. 7) Show the City Force line that exists within 761" Ave W. DRY UTILITIES 1) No comments at this time. If location of utilities change comments may arise. STORM 1) OK 2) OK 3) OK 4) OK STORMWATER ENGINEER REVIEW See below for additional comments. The previous review comments by City Stormwater Engineer, Zachary Richardson have been addressed. Please contact Zack directly at 425-771- 0220 or by email at zacharv.richardson(&edmondswa.gov with any specific questions you may have regarding his comments. 1) The final drain pipe, connecting to the public drainage system, is laid backwards and will direct right-of-way runoff onto the site. Revise the drainage design so that a minimum of 0.5% positive slope is achieved. Page 3 of 3