Engineering Comments-1.pdfof ED40 CITY OF EDMONDS CIVIL PLAN REVIEW COMMENTS ENGINEERING DIVISION �sr_ ig90 (425) 771-0220 City Website: www.edmondswa.gov DATE: April 25, 2019 TO: Jesse Jarrell, Western Engineers jessej@wesi.co FROM: JoAnne Zulauf, Engineering Technician Joanne.zulauf@edmondswa.gov RE: Subdivision File #: ph120180037 Project: Evans Short Plat 2-Lot Project Address: 20020 83rd Ave W During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit two (2) sets of revised plans/documents with a written response to each of the items below to an engineering technician. Resubmittals can be made at the Development Services Department on the 2nd floor of City Hall. Permit Center hours are M, T, Th & F from 8am-4:30pm and on Wednesdays from 8:30am-noon. City of Edmonds handouts, standard details and development code can be referenced on the City website. GENERAL 1. 4/25/19 Under Review. Please provide an itemized engineers cost estimate for both on -site and off -site (right-of-way) improvements, including all utilities, traffic control, NGPA fencing and restoration/enhancement plantings. Use the King County Site Improvement Bond Quantity Worksheet and utilize the "write-in" sections where appropriate. • At a minimum, a bond is required to be placed for all erosion control measures and right-of- way improvements. Please note, if you intend to post a bond in order to record the subdivision and ahead of constructing the required improvements, the bond amount shall be based on the entire scope of the project. The amount of the bond will be based on 120% of the City approved estimate. The City will inform you of the appropriate bond amount after review of the cost estimate. Please obtain the appropriate subdivision improvement bond forms from the City — available on the City website. Inspection fees for this project will be calculated at 3.3% of the 100% City approved estimate for all improvements. Sheet 2 — Grading and SWPPP 1. General Construction Notes. a. Please revise general note #1 to reference the applicable versions of the WSDOT/APWA and the SWMMWW. b. Revise general note #19. There is no detention system being installed for stormwater on this project. c. Please see the General Notes provided on our website for the current city water quality technician. 2. Show job shack location, if any. 3. Please show a rock construction entrance or add call out if existing driveway will be used. 4. Expand clearing limits to include the work in the road. SHEET 4 Road, Drainage and Utility Notes 1. The City's Public Works Operations and Maintenance Department provides Fire/Aid address signs, as required, upon payment of required fees ($75/sign). One (1) fire aid address sign will be required with the proposed development and the plans shall reflect a process that requires the contractor/property owner to contact the Engineering Division by email at engineeringpemits(a)edmondswa.gov 2-weeks in advance of the requested sign fabrication. 2. Please add a note to the plans that states the painted fogline and centerline will be restriped, as required, prior to project completion. 3. Revise plans to show widening of the south bound lane of 83rd Ave W to provide for minimum 11-ft wide travel lanes. Add a cross section of 83rd to the plans showing existing and proposed. 4. Utility patches shall be combined and full width or half width overlay will be required depending on the extent of disturbance. Where utility patches fall entirely within one travel lane, the overlay shall extend to the centerline of roadway. Where utility patches extend into both travel lanes then a full width overlay is required. Revise plans as needed to show the full sawcut areas consistent with this policy and add note to this effect on the plans. Sheet 6 — WATER & SANITARY SEWER 1. 6" cleanout required on the right of way side of the property line with 12" lamphole cover with 1/2" hexbolts. 2. Move all side sewer invert information to this sheet. 3. Add note to plans: "Side Sewer shall be TV'd by property owner/contractor to determine condition for reuse. A copy of the TV shall be submitted to the Public Works building for review." 4. Add note to plans: "Sewer Lateral shall be TV'd by the City to determine condition for reuse. Once exposed, please call the Sewer Division at 425-771-0235." 5. Provide an approx. invert for the existing side sewer stub. 6. Add note that City will TV sewer main prior to final acceptance. 7. Meter(s) shall be placed against the right of way side of property line and outside of driveway approach. 8. Show blue reflector required in the street ROW identifying fire hydrant locations. Refer to City Standard Detail. 9. Hydrant shall be a distance of 3 ft from the edge of pavement. 10. Revise fire line connection to the main. The connection shall reflect the information provided on the standard detail. Page 2 of 3 Sheet X of X — TRAFFIC CONTROL 1. Please submit a traffic control and haul route plan for review and approval. STORMWATER ENGINEER REVIEW Refer to attached plan review comments by City Stormwater Engineer, Zachary Richardson. Please contact Zack directly at 425-771-0220 or by email at zachary.richardson(a edmondswa.i!ov with any specific questions you may have regarding his comments. Page 3 of 3