Loading...
Engineering Comments-Civil Revision 1.pdfCITY OF EDMONDS CIVIL PLAN REVIEW COMMENTS ENGINEERING DIVISION (425) 771-0220 City Website: www.edmondswa.gov DATE: July 29, 2019 TO: Rob Michel rwmichel@nwlink.com FROM: Jeanie McConnell, Engineering Program Manager jeanie.mcconnell@edmondswa.gov RE: Subdivision File 4: PLN20130020 Project: Soundview Lane — 3 lot SP — REVISION 1 Project Address: 7231 Soundview Lane During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit three (3) sets of revised plans/documents with a written response to each of the items below to an Engineering Technician. City of Edmonds handouts and standard details can be referenced on the City website under Permit Assistance. 1) A revision was submitted to construct two keystone block retaining walls instead of rockeries. Plans showing the revision were submitted, but there were no calculations accompanying the submittal and some information was missing that would allow for a complete review of the submittal. Please address/respond to the following: a. Provide structural calculations for the retaining wall b. Provide top and bottom of wall elevations at each end of the proposed retaining wall c. Indicate distance between house and wall. Will a surcharge be placed on the wall by the home? Please note if there is a basement or if no basement, include foundation elevation if there is a potential surcharge. Page 1 of 1