Loading...
Engineering Review Comments 1.pdfof Ell-'Vo CITY OF EDMONDS PLAN REVIEW COMMENTS 4�3"'A ENGINEERING DIVISION .(425) 771-0220 City Website: www.edmondswa.gov DATE: August 10, 2018 TO: Greg Andrews greg@tutmarc.com FROM: Jennifer Lambert, Engineering Technician Jennifer.lambert@edmondswa.gov RE: Application 4: BLD20181039 Project: Thronson — Hot tub Project Address: 18604 Soundview PI During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please submit revised plans/documents including a written response to each item below. Resubmittals can be made at the Development Services Department on the 2nd floor of City Hall. Permit Center hours are M, T, Th & F from 8am-4:30pm and on Wednesdays from 8:30am-noon. City of Edmonds handouts, New updated standard details with new reference numbers, application and other forms, and development code may be referenced on the City website: www.edmondswa.gov under Services/Permits and Development. 1) Show a cleanout in the vicinity of the hot tub for the draining of the hot tub. a. Hot tubs cannot have a direct connection to sanitary sewer. Drainage of hot tubs must be pumped to sewer system via cleanout. b. The cleanout shall be located 20-30' from the hot tub. c. Please revise the plans accordingly. 2) Submit Side Sewer Permit Application form if you need to install a cleanout. 3) Please show an AVB installed at the nearest fill location (hose bib). 4) Please add a note to the plans that all disturbed soils will be compost amended per BMP T5.13.