Loading...
Engr and Storm Request for Info2-Langford 2lot SP-PLN20180064.pdfMEMORANDUM REQUEST FOR ADDITIONAL INFORMATION Date: June 20, 2019 To: Kernen Lien, Environmental Programs Manager From: Jeanie McConnell, Engineering Program Manager Subject: PLN20180064, Langford 2-lot short plat 1136 Vista Place The comments provided below are based upon review of the preliminary civil plans & documents for the subject short plat. Additional information is requested from the applicant at this time in order to continue review of the application and provide preliminary approval of the short plat. Please ask the applicant to provide a written response to each of the comments below and revise and resubmit plans accordingly. Comments 1 — December 6, 2018 Comments 2 — June 20, 2019 GENERAL 1. ok 2. ok 3. ok 4. June 20, 2019 — The driveway for existing lot 1 has been shown to cross the adjacent parcel (parcel # 00507000002200). Is there an existing access easement across this property? 12/6/2018 comment - Show existing access easement areas and existing pavement areas on one plan sheet. Will the existing and proposed pavement areas fall within existing easement areas? 5. ok 6. June 20, 2019 — Pavement width shall be a minimum of 12-feet given only 2 lots will be taking access from the existing private road on the west side of the development. Revise the preliminary development plan to show required road widening. 12/6/2018 comment - Refer to South Snohomish County Fire District comments for access width requirements. City of Edmonds UTILITIES 1. ok 2. ok 3. ok STORMWATER ENGINEER REVIEW Refer to attached plan review comments by City Stormwater Engineer, Zachary Richardson. Please contact Zack directly at 425-771-0220 or by email at zachary.richardson(a,edmondswa.gov with any specific questions you may have regarding his comments. As noted under comment #3 in the attached stormwater comments, the geotech aspect of the subject plan review will be sent out for peer review due to the steep slope, critical area nature of the project. The peer review fee will be pass through to the applicant. As of the writing of the stormwater comments, it has since been decided that the peer review is will be placed on hold until all review comments provided by the City Planning Division have been addressed. Thank you. of E°M STO RM WATE R REVIEW COMMENTS City of Edmonds Engineering Division To: Applicant Date: June 18, 2019 Project Name: Langford 2-lot Short Plat Permit Number: PLN20180064 Address: 1136 Vista PI Review Type: Preliminary Plat Submittal Date: 6/04/19 Reviewer: Zack Richardson, PE City of Edmonds, Stormwater Engineer Recommendation: I recommend that PLN20180064 be withheld until the comments below are adequately addressed. Review Comments: 1. Please identify the overflow routes for both the pump system and infiltration system in the event of failure; address or mitigate impacts as need to avoid creating erosion or flooding nuisances issues. 2. Update plans to address the retrofit requirements of ECDC 18.30.060.D.5.b.i for any existing unmitigated impervious surfaces to remain; please provide a developed conditions exhibit to identify which areas are included for mitigation and show & sum the retrofit and new plus replaced areas separately. a. Appendix A suggests that all BMPs are infeasible for the existing roadway, however, is appears the propose CB could easily be located in a location which would collect a portion of the existing access road and the proposed driveway (or add a second CB) and the same BMP can serve both surfaces. 3. Additional concerns for the proposal of infiltration in this critical geotechnical area have been raised and additional geotechnical review is being requested. Please address all comments provided by the geotechnical reviewer (consultant). Page 1 of 1