Loading...
Exhibit 2-Landau Associates Geotech report.pdfRECEIVED LANDAU JUL 3 0 1991 ASSOCIATES. INC. COMMDIa CTORVICES Erg neerro a!Y! e&vt-j9i3<_ . July 30, 1991 City of Edmonds. - 250 Fifth Avenue North Edmonds, WA 98020 Attention Mr. Peter Hahn RE: PRELfMINARY GEOTECHNICAL INVESTIGATION EDMONDS SHOPPING CENTER EDMONDS, WASHINGTON This letter presents the results of our preliminary geotechnical investigation for the Edmonds Shopping Center property, located at the northwest corner of the intersection of Dayton Street and State Route 104 (Sunset Avenue) in Edmonds, Washington. The purpose of our services was to provide information regarding the property's geologic condition and geotechnical considerations related to potential future site development. Our work has been accomplished in general accordance with the scope of services described in Supplemental No. 1 to our agreement with the City of Edmonds (City) dated June 11, 1991. The site is approximately 4.4 acres in size, relatively- flat (gentle upward slope to the north and east), and is located northwest of the intersection of Dayton Street and State Route 104. The site is presently asphalt paved and was occupied by a Safeway food store and several small businesses in attached strip malls at the time of our field work_ Structures at the site do not appear to show exterior distress. A conversation with a Safeway employee indicated that interior floor warping is present within the food store. The existing pavement is moderately patched and shows some signs of settlement, particularly towards the edges of the parking lot. Document Review Several sources of geotechnical information for the site and nearby properties were reviewed. The information from these sources, combined with information from our exploratory borings, is the basis for our preliminary assessment of geologic conditions and development considerations for the site. The following information sources, from our files and the City of Edmonds' records, were reviewed:- 07/30/91 eviewed 07/30/91 MAONMRAHN0729-LET 1'.0. flox b129 • iil)�11-)Nt)�, WA HINC f(1N 9020-9129 • +2,)h) 776-N7U" • 1i15: 12"u) 77= r...K) • Boring logs for the site from an investigation performed by Pittsburgh Testing Laboratory, March 12, 1966 • Boring Logs from the Comprehensive Sewerage Plan, Reid Middleton and Associates, March 31, 1969; fo; property at southeast intersection of $tate Route 104 and Dayton Street . • Washington State Department of Highways Soils Report for State'3toute 104, Ferry St. to 5th Ave., November 1, 1967 • goring Logs by Washington State Department of Highways for Dayton St. Sewer" Line, March 1970 • Various geotechnical reports and letters for the Harbor Square Development at the southwest corner of Dayton Street and State Route 104, by Hemphill Consulting Engineers, including Edmonds . Athletic Club, Building No. 6 (October 8;1984); Edmonds Athletic Club, Building No. 6 (December 10,1984); Harbor Inn Hotel, Building No. 8 (February 25,1984); Harbor Square, Building No. 2 (February 25,1984) • Geotechnical report for Alaska NW Publishing Co. by Charles C. May Consulting Engineers, June 22, 1974 • Geotechnical report for Alaska Magazine Warehouse by Neil Twelker and Associates, December 21, 1976 • Geotechnical report for Alaska NW Publishing Co. Addition by Neil Twelker and Associates, February 7,1978 • Geotechnical report for South County Senior Center Addition by Cascade Testing Laboratory, Inc., August 15,1976. Subsurface Conditions In addition to a review of available information, three soil borings were completed at the site to further characterize existing site conditions. These borings were advanced to depths of 19 to 23 ft; boring locations are shown on the Site Map, Figure 1. Soils encountered during boring advancement were classified in accordance with the soil classification system presented in Attachment 1. Logs of these explorations are also attached (Attachment 2). The site is underlain by fill overlying soft organic silt. The organic silt is underlain by a variable thickness of medium dense to very dense sand and gravel deposits, which are underlain by glacial till. The fill consisted of 4.5 to 7.5 ft of medium dense silty sand and gravel. The organic silt ranged from about 2.5 to 10 ft thick in the Landau Associates' borings, has a very soft to soft consistency, and includes silt, variable amounts of organics, and occasional peat. Native soils beneath the silt/organic layer include medium dense to very dense, clean mM/n MMortnsu AHNO 2s.Ler 2 sand and gravel and silty sand. Groundwater was encountered at the time of drilling,at 9.0 to 14.0 ft below the existing ground surface, although static water levels may be shallower. The subsurface conditions encountered in the Landau Associates' borings are consistent with those anticipated based on our document review. General Site Development Sulistirface conditions are generally conducive to future site development. However, the soft organic soils at the site are susceptible to significant settlements, even under relatively light loading conditions. Consequently, all buildings or settlement sensitive structures should be founded on piles extended at least to the sand and gravel units underlying native soft/organic soils. Depending on the design loads, it may be necessary tb extend piles into the glacial till, anticipated to be present at depths of 20 ft or more below existing site grades. With proper site preparation, typical floor loads can be supported on structural slabs placed at the existing site grades. If the grade in the floor slab area is raised, or if high floor loads are anticipated, it may be necessary to preload the floor slab area to minimize post construction settlements, or support floor slab loads on piles. If the existing site grade is raised over large areas, areal settlement is anticipated. To m minimize areal settlements subsequent to construction, it aybe necessary to place preload fill prior to construction or grading. Our observations of existing parking lot pavement performance also indicate possible differential settlement at the site. Minimizing site grade changes and preloading can reduce the magnitude of differential settlements. Because of the high likelihood of* site .settlement, flexible utility connections to main utility lines and structures may be advisable. The length of time and amount of preload required would be dependent on specific subsurface conditions, design site grades and loadings, and construction schedules. Use of this Letter Landau Associates has provided these preliminary geotechnical recommendations for the City of Edmonds to aid in the evaluation of the Edmonds Shopping Center property. The recommendations made in this letter are based on assumptions that site soil conditions were reasonably defined by our field explorations and document review. Our recommendations are preliminary and are not appropriate for use as the basis of site development or design. Should the City purchase the property, additional geotechnical investigation, laboratory testing, and engineering analyses are recommended once site development plans are available. 07/30/91 EDMOMMHAHNW LET 3 '.:•,••,±)A',' : S'li, V*TAi ,':! Landau Associates has performed this preliminary geotechnical investigation in accordance with generally accepted engineering practices in effect in the Snohomish County area at the time the services' were provided. This warranty stands in lieu of all other warranties, express or implied. While this report can'be used as a guide, it must be understo6d that it is neither a rejection nor an endorsement of the site. , We appreciate the opportunity of working with the City of Edmonds on this project and look forward to assisting you in the future. Please contact us if you have any questions regarding the information contained in this report. LANDAU ASSOCIATES, INC. By. wrence Beard, P.E. Pmject M nager and Deborah Ladd Senior Staff Engineer LDB/DL/njb No. 7431.10 Attachments 07/30/91 MM0NDBgMM074 1V 4 -,rr:i. IN(. e Jamas Street —;.— — KEY B-1 B-3 ' Approximate Boring ` Location and Identification Parking Restaurant �I I �G7 Shops Parking 9`0' i I \P ® B-2 SAFEWAY I Parking F / / V;Shops B -3X/ e0- HARBOR SQUARE � Parking o Oaf II /� V Adapted from Alan Gerard Design Incorporated (1984). Site Map 5 0 100 200 Approximate Scale In Feet Figure 1 SOIL CLASSIFICATION SYSTEM MAJOR GRAPHIC LETTER SYMBOL SYMBOL() TYPICAL (2)(3) DESCRIPTIONS OlVIigIONS t# "jN W ii graded gravel: graveVsand mlxture(s); CLEAN GW oft or no linea GRAVEL AND GRAVEL GRAVELLY SOIL (Little or;. •. poorly -graded gravel; gtavel/sand mixture(s); .;+. GP no fines) d .• a :. �Q 0 ` little or hofines .0 ^ (Moro than 50'k GRAVEL of coarse fraction GM Sil avel; gravel/sand/silt mixtures) ry gr o retained an WITH FINES rA w04 sieve) amount c fble GC zap Clayey gravel; gravet/sand/silt mixwm(s) � CLEAN �+::. =:� �'.: .; ; SW Well -graded sand: rave{ sand; Little or no flees g gravelly tiw SAND AND SAND SANDY SOIL (Little or SP poorly -graded sand; gravelly sand; little or no Mies V no fines) 50% ;.i :2 9 (Mare than of coarse fraction SAND : SM Silty sand: sand/sllt mixture(s) passed through WITH FINES $4 sieve) (Appreciable ` SC Clayey sand; sandiday mixture(s) amount of fines) Inorganic silt and very One sand; rock floor: silty- or ML clayey -fine sand or clayey silt with slight plasticity .0 o SILT AND CLAY inorganic day of low to medium plasticity; gravelly CL clay: sandy day; sary day; lean day O (Liquid Limit less than 50) c a OL Organic silt; organic, silty clay of low plasticity tu o MH Inorganic sill; micaceous or diatomaceous fine sand or silty soil ku z SILT AND CLAY CH Inorganic day of high plasticity; fat day m (Liquid Limit greater than So) OH Organic day of medium to high plasticity; organic sill HIGHLY ORGANIC SOIL PT Peat; humus; swamp soil with high organic content Notes: 1. Dual tetter symbob it.e., SM -SP) for a sand or gravel itkdlc re a soil wile an ostlmated S 15% floes. Multiple letter symbols P.O.. MUCL) Irdl-tes bordergne or nulltipte 90111 dassill0a110ns. Only oro twit loner symbors mspective pattern Is shown 0n logs. 2. Sol descriptions shown on logs use the tem+ind09y and general approach for thio Visual•At vow Procedrre. DascrOftn and /ddVWft r(on al softs. as outlined In ASTM D 2488. 3. Sou descriptions (wh1ch are based On estimated values) are as follows: Primary Soil Type(s) - I.e.,'GRAVEL'.'SNNIr.'SILT, �WY', 0t0. Secondary Soil Type(s) (:05%) - I.e..'gravety','sanW,'dayey'. etc. Modlfler(a) (a5% and S1 S%) - I.e..'Wilh Omer, *Www sand", "with day'. etc. Minor Compon(nt(s) (s5%) - I.e.,'trace graver,'traee sartd'.'Irace day', etc Soil Classification System I Attachment 1 _ t 3 Boling 1 Approximate Elevation 15 Feet Depth (fest) Soil Classilication System Symbol Description Sample Interval (feet) Blows per Foot(a) » System 2' asphalt Interval (feet) Fpper 01-75 SM/GM• Medium brown and gray, fine to coarse SAND wRh gravel and silt, and fine to coarse GRAVEL with sand and sift (medium dense, moist) (fill) 2.51.0 23 7.5-10.0 MUOL ganics ganics andk brown s reads, anmedium gray-brown oro ganic SILT (very soft, 7.5-9.0 1 for 18' 0.1-4.5 SWGM moist) 2.5-4.0 12 10.0-17.5 SP Gray. medium to coarse SAND with gravel 12.5-14.0 38 (medium dense to dense, wet) 17.5.19.0 GP Gray, fine to coarse GRAVEL with sand (dense to 17.5-19.0 52 very dense, wet) Boring completed to 19.0 ft on 7/15/91. Groundwater encountered at time of drilling at 9.0 ft. Boring 2 Approximate Elevation 15 Feet 8.5.14.0 ML/OL Dark brown SILT with organics interleyered with 12.5-14.0 1 for 18' thin layers of gray, fine to coarse sand; sandier towards base, gradational contact (very soft, moist) 14.0-18.5 SP Gray, medium to coarse SAND with gravel and 17.5-19.0 21 trace silt (medium dense, wet) 18.5-225 SM Gray, silty, fine SAND with gravel (medium dense 21.0-22.5 40 to dense, moist) (till) Boring completed to 225 ft on 7/15191. Groundwater encountered at time of drilling at 14.0 ft. (a) Blows required to drive 2.0 -Inch OD split -barrel sample 1 foot with a hammer weight of 140 pounds and a stroke of 30 Inches. LANDAU ASSOCIATES, INC. Log of Borings 7 Attachment 2 Sod Classification Sample Blows Depth System Interval (feet) Fpper (feet) Symbol Description » 2' asphalt 0.1-4.5 SWGM Medium brown to gray, silty fine to coarse SAND 2.5-4.0 12 with gravel and silly fine to coarse GRAVEL with sand (medium dense, moist to wet) (fill) 4.5-8.5 OUPT Dark brown to brown -black, organic SILT and 7.5-9.0 3 PEAT (very soft, moist) 8.5.14.0 ML/OL Dark brown SILT with organics interleyered with 12.5-14.0 1 for 18' thin layers of gray, fine to coarse sand; sandier towards base, gradational contact (very soft, moist) 14.0-18.5 SP Gray, medium to coarse SAND with gravel and 17.5-19.0 21 trace silt (medium dense, wet) 18.5-225 SM Gray, silty, fine SAND with gravel (medium dense 21.0-22.5 40 to dense, moist) (till) Boring completed to 225 ft on 7/15191. Groundwater encountered at time of drilling at 14.0 ft. (a) Blows required to drive 2.0 -Inch OD split -barrel sample 1 foot with a hammer weight of 140 pounds and a stroke of 30 Inches. LANDAU ASSOCIATES, INC. Log of Borings 7 Attachment 2 Baling 3 Approximate Elevation 15 Feet (a) Blows required to drive 2.0 -inch OD split -barrel sample 1 toot with a hammer weight of 140 pounds and a stroke of 30 inches. LANDAU ASSOCIATES, INC. 8 Log of Borings Attachment 2 son Sample Blows Classification Interval per Foot(a) Depth (feet) System , Symbol Description (feet) 3" .asphalt SM/GM Medium brown to gray, silty, fine to coarse SAND 2.5~4:0 8 0.2-4.5 with gravel and silty fine to coarse GRAVEL with sand (loose, moist to wet) (till) 4.5-9.5 MUOL Medium brown and dark brown SILT with organics, 7.5-9.0 3 twigs and reeds, and organic SILT (very soft to soft, moist) 9.5-22.0 SW/GW Dark gravel and GRAVEL wite to coarse SAND h with silt (dense 12.5-14.0 17.5-19.0 87 50 for 5.5" sandy fine ton coarse to very dense, wet) 22.0-23.0 SP/SM Gray, medium to coarse SAND with gravel grading 22.5-23.5 50 for 5" to gray, fine to medium SAND with silt and gravel (very dense, moist) (till) Test ph completed to 23.0 It on 7115/91. Groundwater encountered at time of drilling at 9.5 R. (a) Blows required to drive 2.0 -inch OD split -barrel sample 1 toot with a hammer weight of 140 pounds and a stroke of 30 inches. LANDAU ASSOCIATES, INC. 8 Log of Borings Attachment 2