existing monopole structural analysis.pdf Date: September 17, 2014 Marianne Dunst GPD Group Crown Castle 520 S Main St. Suite 2531 3530 Toringdon Way Suite 300 Akron, OH 44311 Charlotte, NC 28277 (614) 859-1607 (704) 405-6580 dpalkovic@gpdgroup.com Subject: Structural Analysis Report Carrier Designation: AT&T Mobility Co-Locate Carrier Site Number: WA358 Carrier Site Name: Lake Ballinger Crown Castle Designation: Crown Castle BU Number: 840470 Crown Castle Site Name: LAKE BALLINGER Crown Castle JDE Job Number: 298709 Crown Castle Work Order Number: 918275 Crown Castle Application Number: 255122 Rev. 9 Engineering Firm Designation: GPD Group Project Number: 2014777.840470.01 Site Data: 23931 Highway 99, Edmonds, WA 98026 Snohomish County Latitude 47° 46' 54.3'', Longitude -122° 20' 37.9'' 57 Foot – EEI Monopole Tower Dear Marianne Dunst, GPD Group is pleased to submit this “Structural Analysis Report” to determine the structural integrity of the above mentioned tower. This analysis has been performed in accordance with the Crown Castle Structural ‘Statement of Work’ and the terms of Crown Castle Purchase Order Number 703012, in accordance with application 255122, revision 9. The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have determined the tower stress level for the structure and foundation, under the following load case, to be: LC5: Existing + Proposed Equipment Sufficient Capacity Note: See Table I and Table II for the proposed and existing/reserved loading, respectively. This analysis has been performed in accordance with the 2012 International Building Code based upon an ultimate 3-second gust wind speed of 110 mph converted to a nominal 3-second gust wind speed of 85 mph per section 1609.3.1 as required for use in the TIA-222-G Standard per Exception #5 of Section 1609.1.1. Exposure Category C and Risk Category II were used in this analysis. We at GPD Group appreciate the opportunity of providing our continuing professional services to you and Crown Castle. If you have any questions or need further assistance on this or any other projects please give us a call. Structural analysis prepared by: Tommy Knott, EI Respectfully submitted by: John N. Kabak, S.E. Washington #: 50892 520 South Main Street . Suite 2531 . Akron, Ohio 44311 . 330-572-2100 . Fax 330-572-2101 . www.GPDGroup.com Glaus, Pyle, Schomer, Burns & De Haven, Inc. dba Glaus, Pyle, Schomer, Burns & De Haven, PC 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 2 TABLE OF CONTENTS 1) INTRODUCTION 2) ANALYSIS CRITERIA Table 1 - Proposed Antenna and Cable Information Table 2 - Existing and Reserved Antenna and Cable Information Table 3 - Design Antenna and Cable Information 3) ANALYSIS PROCEDURE Table 4 - Documents Provided 3.1) Analysis Method 3.2) Assumptions 4) ANALYSIS RESULTS Table 5 - Section Capacity (Summary) Table 6 - Tower Components vs. Capacity 4.1) Recommendations 5) APPENDIX A tnxTower Output 6) APPENDIX B Base Level Drawing 7) APPENDIX C Additional Calculations tnxTower Report - version 6.1.4.1 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 3 1) INTRODUCTION The existing 57' monopole has two major sections connected by a slip joint. It has 12 sides and is evenly tapered from 25.0" (flat-flat) at the base to 13.5" (flat-flat) at the top. The structure is galvanized and has no tower lighting This tower is a 57 ft Monopole tower designed by Engineered Endeavors, Inc. in February of 1999. The tower was originally designed for a wind speed of 90 mph per TIA/EIA-222-F. 2) ANALYSIS CRITERIA This analysis has been performed in accordance with the 2012 International Building Code based upon an ultimate 3-second gust wind speed of 110 mph converted to a nominal 3-second gust wind speed of 85 mph per section 1609.3.1 as required for use in the TIA-222-G Standard per Exception #5 of Section 1609.1.1. Exposure Category C and Risk Category II were used in this analysis. Table 1 - Proposed Antenna and Cable Information Center Number Number Feed Mounting Line Antenna of Antenna Model of Feed Line Note Level (ft) Elevation Manufacturer Antennas Lines Size (in) (ft) 3 Alcatel Lucent 3JR52703AAAA 3 Alcatel Lucent 9442 RRH 700 W/SOLAR 3 Alcatel Lucent RRH 2x60W-1900MHz 2 3/8 57.0 60.0 3 Alcatel Lucent RRH2X40-07L-DE 1 4 3/4 3 Alcatel Lucent RRH4X25-WCS 3 Commscope SBNHH-1D65C 1 Raycap DC6-48-60-18-8F Notes: 1) See Appendix B for proposed coax layout. tnxTower Report - version 6.1.4.1 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 4 Table 2 - Existing and Reserved Antenna and Cable Information Center Number Number Feed Mounting Line Antenna of Antenna Model of Feed Line Note Level (ft) Elevation Manufacturer Antennas Lines Size (in) (ft) 12 Kathrein 860 10025 Powerwave 6 LGP21401 Technologies 1 3/8 1 Raycap DC6-48-60-18-8F 12 7/8 6 Ericsson KRY 112 71/2 6 Kathrein 742 265 60.0 57.0 Powerwave 2 P65-17-XLH-RR Technologies KMW 1 AM-X-CD-16-65-00T-RET 6 7/8 1 Communications 3 Kathrein 742 265 3 Alcatel Lucent 9442 RRH 57.0 1 Platform Mount \[LP 601-1\] 42.0 3 Kathrein 840 10054 41.0 41.0 1 Side Arm Mount \[SO 104-3\] 6 5/16 38.0 3 Motorola DAP Vx RF 40.0 40.0 1 Pipe Mount \[PM 601-3\] Notes: 1) Equipment to be Removed Table 3 - Design Antenna and Cable Information Center Number Number Feed Mounting Line Antenna of Antenna Model of Feed Line Level (ft) Elevation Manufacturer Antennas Lines Size (in) (ft) 4 AP 193320 8 AP 199016 57 57 Low Profile Platform w/ T- 1 Mounts Low Profile Platform w/ T- 1 Mounts 47 47 9 SP 9014 3) ANALYSIS PROCEDURE Table 4 - Documents Provided Document Remarks Reference Source Earth Consultants Project #: E- 4-GEOTECHNICAL REPORTS5096443 CCISITES 7147-357, Dated 9/1/1998 4-TOWER FOUNDATION Engineered Endeavors Project #: 5096434 CCISITES DRAWINGS/DESIGN/SPECS 4628, Dated 2/15/1999 4-TOWER MANUFACTURER Engineered Endeavors Project #: 5096394 CCISITES DRAWINGS 4628, Dated 2/15/1999 tnxTower Report - version 6.1.4.1 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 5 3.1) Analysis Method tnxTower (version 6.1.4.1), a commercially available analysis software package, was used to create a three-dimensional model of the tower and calculate member stresses for various loading cases. Selected output from the analysis is included in Appendix A. 3.2) Assumptions 1) Tower and structures were built in accordance with the manufacturer’s specifications. 2) The tower and structures have been maintained in accordance with the manufacturer’s specification. 3) The configuration of antennas, transmission cables, mounts and other appurtenances are as specified in Tables 1 and 2 and the referenced drawings. 4) When applicable, transmission cables are considered as structural components for calculating wind loads as allowed by TIA-222-G. This analysis may be affected if any assumptions are not valid or have been made in error. GPD Group should be notified to determine the effect on the structural integrity of the tower. 4) ANALYSIS RESULTS Table 5 - Section Capacity (Summary) Section Component Critical SF*P_allow % Elevation (ft)SizeP (K)Pass / Fail No.TypeElement(K)Capacity L157 - 27PoleTP19.82x13.5x0.18751-6.15802.4772.2Pass L227 - 0PoleTP25x18.813x0.252-9.191405.9772.3Pass Summary Pole (L2)72.3Pass Rating = 72.3Pass Table 6 - Tower Component Stresses vs. Capacity – LC5 Notes Component Elevation (ft) % Capacity Pass / Fail 1 Anchor Rods 0 73.7 Pass 1, 2 Base Plate 0 83.8 Pass 1 Base Foundation 0 43.6 Pass Base Foundation 1 0 35.1 Pass Soil Interaction Structure Rating (max from all components) = 83.8% Notes: 1) See additional documentation in “Appendix C – Additional Calculations” for calculations supporting the % capacity consumed. 2) Capacities up to 105% are considered acceptable based on analysis methods used. 4.1) Recommendations The existing tower and its foundation are sufficient for the proposed loading and do not require modifications. tnxTower Report - version 6.1.4.1 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 6 5) DISCLAIMER OF WARRANTIES GPD GROUP has not performed a site visit to the tower to verify the member sizes or antenna/coax loading. If the existing conditions are not as represented on the tower elevation contained in this report, we should be contacted immediately to evaluate the significance of the discrepancy. This is not a condition assessment of the tower or foundation. This report does not replace a full tower inspection. The tower and foundations are assumed to have been properly fabricated, erected, maintained, in good condition, twist free, and plumb. The engineering services rendered by GPD GROUP in connection with this Structural Analysis are limited to a computer analysis of the tower structure and theoretical capacity of its main structural members. No allowance was made for any damaged, bent, missing, loose, or rusted members (above and below ground). No allowance was made for loose bolts or cracked welds. This analysis is limited to the designated maximum wind and seismic conditions per the governing tower standards and code. Wind forces resulting in tower vibrations near the structure’s resonant frequencies were not considered in this analysis and are outside the scope of this analysis. Lateral loading from any dynamic response was not evaluated under a time-domain based fatigue analysis. GPD GROUP does not analyze the fabrication of the structure (including welding). It is not possible to have all the very detailed information needed to perform a thorough analysis of every structural sub-component and connection of an existing tower. GPD GROUP provides a limited scope of service in that we cannot verify the adequacy of every weld, plate connection detail, etc. The purpose of this report is to assess the capability of adding appurtenances usually accompanied by transmission lines to the structure. It is the owner’s responsibility to determine the amount of ice accumulation in excess of the code specified amount, if any, that should be considered in the structural analysis. The attached sketches are a schematic representation of the analyzed tower. If any material is fabricated from these sketches, the contractor shall be responsible for field verifying the existing conditions, proper fit, and clearance in the field. Any mentions of structural modifications are reasonable estimates and should not be used as a precise construction document. Precise modification drawings are obtainable from GPD GROUP, but are beyond the scope of this report. Miscellaneous items such as antenna mounts, etc., have not been designed or detailed as a part of our work. We recommend that material of adequate size and strength be purchased from a reputable tower manufacturer. Towers are designed to carry gravity, wind, and ice loads. All members, legs, diagonals, struts, and redundant members provide structural stability to the tower with little redundancy. Absence or removal of a member can trigger catastrophic failure unless a substitute is provided before any removal. Legs carry axial loads and derive their strength from shorter unbraced lengths by the presence of redundant members and their connection to the diagonals with bolts or welds. If the bolts or welds are removed without providing any substitute to the frame, the leg is subjected to a higher unbraced length that immediately reduces its load carrying capacity. If a diagonal is also removed in addition to the connection, the unbraced length of the leg is greatly increased, jeopardizing its load carrying capacity. Failure of one leg can result in a tower collapse because there is no redundancy. Redundant members and diagonals are critical to the stability of the tower. GPD GROUP makes no warranties, expressed and/or implied, in connection with this report and disclaims any liability arising from material, fabrication, and erection of this tower. GPD GROUP will not be responsible whatsoever for, or on account of, consequential or incidental damages sustained by any person, firm, or organization as a result of any data or conclusions contained in this report. The maximum liability of GPD GROUP pursuant to this report will be limited to the total fee received for preparation of this report. tnxTower Report - version 6.1.4.1 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 7 APPENDIX A TNXTOWER OUTPUT tnxTower Report - version 6.1.4.1 Platform Mount \[LP 601-1\] Pipe Mount \[PM 601-3\] DAP Vx RF DAP Vx RF DAP Vx RF 840 10054 w/ Mount Pipe 840 10054 w/ Mount Pipe 840 10054 w/ Mount Pipe Side Arm Mount \[SO 104-3\] (4) 860 10025 (4) 860 10025 (4) 860 10025 DC6-48-60-18-8F DC6-48-60-18-8F (2) KRY 112 71/2 (2) KRY 112 71/2 (2) KRY 112 71/2 9442 RRH 700 W/SOLAR 9442 RRH 700 W/SOLAR 9442 RRH 700 W/SOLAR RRH 2x60W-1900MHz RRH 2x60W-1900MHz RRH 2x60W-1900MHz (2) LGP21401 (2) LGP21401 (2) LGP21401 RRH2X40-07L-DE RRH2X40-07L-DE RRH2X40-07L-DE RRH4X25-WCS RRH4X25-WCS RRH4X25-WCS 3JR52703AAAA w/ Mount Pipe 3JR52703AAAA w/ Mount Pipe 3JR52703AAAA w/ Mount Pipe (2) 742 265 w/ Mount Pipe (2) 742 265 w/ Mount Pipe (2) 742 265 w/ Mount Pipe SBNHH-1D65C w/ Mount Pipe SBNHH-1D65C w/ Mount Pipe SBNHH-1D65C w/ Mount Pipe Side Arm Mount \[SO 701-3\] 57 40 41 41 41 41 41 41 41 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 DESIGNED APPURTENANCE LOADING TYPEELEVATIONTYPEELEVATION Platform Mount \[LP 601-1\] 57 RRH 2x60W-1900MHz 57 Side Arm Mount \[SO 701-3\] 57 RRH 2x60W-1900MHz 57 SBNHH-1D65C w/ Mount Pipe 57 9442 RRH 700 W/SOLAR 57 57.0 ft SBNHH-1D65C w/ Mount Pipe 57 9442 RRH 700 W/SOLAR 57 SBNHH-1D65C w/ Mount Pipe 57 9442 RRH 700 W/SOLAR 57 (2) 742 265 w/ Mount Pipe 57 (2) KRY 112 71/2 57 (2) 742 265 w/ Mount Pipe 57 (2) KRY 112 71/2 57 (2) 742 265 w/ Mount Pipe 57 (2) KRY 112 71/2 57 3JR52703AAAA w/ Mount Pipe 57 DC6-48-60-18-8F 57 3JR52703AAAA w/ Mount Pipe 57 DC6-48-60-18-8F 57 3JR52703AAAA w/ Mount Pipe 57 (4) 860 10025 57 RRH4X25-WCS 57 (4) 860 10025 57 RRH4X25-WCS 57 (4) 860 10025 57 RRH4X25-WCS 57 Side Arm Mount \[SO 104-3\] 41 RRH2X40-07L-DE 57 840 10054 w/ Mount Pipe 41 RRH2X40-07L-DE 57 840 10054 w/ Mount Pipe 41 RRH2X40-07L-DE 57 840 10054 w/ Mount Pipe 41 (2) LGP21401 57 DAP Vx RF 41 (2) LGP21401 57 DAP Vx RF 41 (2) LGP21401 57 DAP Vx RF 41 RRH 2x60W-1900MHz 57 Pipe Mount \[PM 601-3\] 40 MATERIAL STRENGTH GRADEFyFuGRADEFyFu A572-65 65 ksi 80 ksi TOWER DESIGN NOTES 1. Tower is located in Snohomish County, Washington. 2. Tower designed for Exposure C to the TIA-222-G Standard. 3. Tower designed for a 85 mph basic wind in accordance with the TIA-222-G Standard. 4. Tower is also designed for a 30 mph basic wind with 0.25 in ice. Ice is considered to increase in thickness with height. 5. Deflections are based upon a 60 mph wind. 6. Tower Structure Class II. 7. Topographic Category 1 with Crest Height of 0.00 ft 8. TOWER RATING: 72.3% 27.0 ft ALL REACTIONS ARE FACTORED AXIAL 12 K SHEARMOMENT 1 K47 kip-ft TORQUE 0 kip-ft 30 mph WIND - 0.2500 in ICE AXIAL 9 K SHEARMOMENT 10 K507 kip-ft 0.0 ft TORQUE 0 kip-ft REACTIONS - 85 mph WIND Job: GPD Group LAKE BALLINGER BU#: 840470 Project: 2014777.840470.01 520 S Main St. Suite 2531 Client: Drawn by: App'd: Crown Castletknott Akron, OH 44311 Code: Date: Scale: TIA-222-G 09/17/14 NTS Phone: (330) 572-2289 GPD Group Path: Dwg No. E-1 FAX: (330) 572-2102 T:\\Crown\\840470\\01\\TNX\\840470.eri Feed Line Distribution Chart 0' - 57' RoundFlatApp In FaceApp Out FaceTruss Leg Face AFace BFace C 57.0057.00 48.5048.5048.5048.50 41.0041.0041.0041.00 27.0027.00 8.008.008.008.008.008.008.008.008.008.008.008.008.008.008.008.00 0.000.00 Job: GPD Group LAKE BALLINGER BU#: 840470 Project: 2014777.840470.01 520 S Main St. Suite 2531 Client: Drawn by: App'd: Crown Castletknott Akron, OH 44311 Code: Date: Scale: TIA-222-G 09/17/14 NTS Phone: (330) 572-2289 GPD Group Path: Dwg No. E-7 FAX: (330) 572-2102 T:\\Crown\\840470\\01\\TNX\\840470.eri 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 8 Tower Input Data There is a pole section. This tower is designed using the TIA-222-G standard. The following design criteria apply: Tower is located in Snohomish County, Washington. 1) Basic wind speed of 85 mph. 2) Structure Class II. 3) Exposure Category C. 4) Topographic Category 1. 5) Crest Height 0.00 ft. 6) Nominal ice thickness of 0.2500 in. 7) Ice thickness is considered to increase with height. 8) Ice density of 56 pcf. 9) A wind speed of 30 mph is used in combination with ice. 10) Temperature drop of 50 °F. 11) Deflections calculated using a wind speed of 60 mph. 12) A non-linear (P-delta) analysis was used. 13) Pressures are calculated at each section. 14) Stress ratio used in pole design is 1. 15) Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not 16) considered. Options Consider Moments - Legs Distribute Leg Loads As Uniform Treat Feedline Bundles As Cylinder Consider Moments - Horizontals Assume Legs Pinned Use ASCE 10 X-Brace Ly Rules Consider Moments - Diagonals Assume Rigid Index Plate Calculate Redundant Bracing Forces Use Moment Magnification Use Clear Spans For Wind Area Ignore Redundant Members in FEA Use Code Stress Ratios Use Clear Spans For KL/r SR Leg Bolts Resist Compression Use Code Safety Factors - Guys Retension Guys To Initial Tension All Leg Panels Have Same Allowable Escalate Ice Bypass Mast Stability Checks Offset Girt At Foundation Always Use Max Kz Use Azimuth Dish Coefficients Consider Feedline Torque Use Special Wind Profile Project Wind Area of Appurt. Include Angle Block Shear Check Include Bolts In Member Capacity Autocalc Torque Arm Areas Poles Leg Bolts Are At Top Of Section SR Members Have Cut Ends Include Shear-Torsion Interaction Secondary Horizontal Braces Leg Sort Capacity Reports By Component Always Use Sub-Critical Flow Use Diamond Inner Bracing (4 Sided) Triangulate Diamond Inner Bracing Use Top Mounted Sockets Add IBC .6D+W Combination Use TIA-222-G Tension Splice Capacity Exemption Tapered Pole Section Geometry Section Elevation Section Splice Number Top Bottom Wall Bend Pole Grade Length Length of DiameterDiameter Thickness Radius ft ft ft Sides in in in in L1 57.00-27.00 30.00 3.00 12 13.5000 19.8200 0.1875 0.7500 A572-65 (65 ksi) L2 27.00-0.00 30.00 12 18.8130 25.0000 0.2500 1.0000 A572-65 (65 ksi) Tapered Pole Properties SectionTip Dia. Area I r C I/C J It/Q w w/t 24342 in in in in in in in in in L1 13.9762 8.0374 181.8118 4.7659 6.9930 25.9991 368.3999 3.9558 3.1155 16.616 20.5192 11.8531 583.1361 7.0284 10.2668 56.7985 1181.59185.8337 4.8093 25.649 L2 20.1172 14.9432 657.2435 6.6456 9.7451 67.4433 1331.75367.3546 4.3719 17.488 25.8819 19.9237 1557.7847 8.8605 12.9500 120.2923 3156.49429.8059 6.0300 24.12 tnxTower Report - version 6.1.4.1 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 9 Tower Gusset Gusset Gusset Grade Adjust. Factor Adjust. Weight Mult. Double Angle Double Angle Elevation Area Thickness AFactor Stitch Bolt Stitch Bolt f (per face) ASpacing Spacing r Diagonals Horizontals 2 ft ft in in in L1 57.00- 1 1 1 27.00 L2 27.00-0.00 1 1 1 Feed Line/Linear Appurtenances - Entered As Round Or Flat Description SectoComponent Placement Total Number Start/EnWidth or PerimeteWeight r Type Number Per Row d Diameter ft Position r plf in in Step Pegs B Surface Ar 57.00 - 8.00 1 1 0.000 0.8000 2.720 (CaAa) 0.000 Safety Line 3/8 B Surface Ar 57.00 - 8.00 1 1 0.000 0.3750 0.220 (CaAa) 0.000 3'' Flex Conduit B Surface Ar 48.50 - 41.00 1 1 0.000 3.0000 0.478 (CaAa) 0.000 Feed Line/Linear Appurtenances - Entered As Area Description Face Allow Component Placement Total CA Weight AA or Shield Type Number 2 Leg ft ft/ft plf * LDF5-50A(7/8'') B No Inside Pole 57.00 - 8.00 12 No Ice 0.00 0.330 1/2'' Ice 0.00 0.330 CR 50 396 PE(3/8'') B No Inside Pole 57.00 - 8.00 1 No Ice 0.00 0.090 1/2'' Ice 0.00 0.090 FB-L98-002-XXX( 3/8)C No Inside Pole 57.00 - 8.00 2 No Ice 0.00 0.065 1/2'' Ice 0.00 0.065 WR-VG86T( 3/4) C No Inside Pole 57.00 - 8.00 4 No Ice 0.00 0.529 1/2'' Ice 0.00 0.529 * 9207(5/16'') B No Inside Pole 41.00 - 8.00 6 No Ice 0.00 0.600 1/2'' Ice 0.00 0.600 3'' Flex Conduit B No Inside Pole 48.50 - 8.00 1 No Ice 0.00 0.478 1/2'' Ice 0.00 0.478 Feed Line/Linear Appurtenances Section Areas Tower Tower Face AACACAWeight R F AA AA Sectio Elevation In Face Out Face 2222 n ft ft ft ft ft K L1 57.00-27.00 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 5.775 0.000 0.27 C 0.000 0.000 0.000 0.000 0.07 L2 27.00-0.00 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 2.232 0.000 0.21 C 0.000 0.000 0.000 0.000 0.04 Feed Line/Linear Appurtenances Section Areas - With Ice Tower Tower Face Ice AACACAWeight R F AA AA Sectio Elevation or ThicknessIn Face Out Face 2222 ftftft n ft Leg in ft K L1 57.00-27.00 A 0.511 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 12.532 0.000 0.33 C 0.000 0.000 0.000 0.000 0.07 tnxTower Report - version 6.1.4.1 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 10 Tower Tower Face Ice AACACAWeight R F AA AA Sectio Elevation or Thickness In Face Out Face 2222 n ft Leg in ft ft ft ft K L2 27.00-0.00 A 0.455 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 6.119 0.000 0.24 C 0.000 0.000 0.000 0.000 0.04 Feed Line Center of Pressure Section Elevation CPCPCPCP X Z X Z Ice Ice ft in in in in L1 57.00-27.00 0.2303 -0.1329 0.4123 -0.2380 L2 27.00-0.00 0.0987 -0.0570 0.2423 -0.1399 Shielding Factor Ka Tower Feed Line Description Feed Line K K aa Section Record No. Segment No Ice Ice Elev. L1 1 Step Pegs 27.00 - 1.0000 1.0000 57.00 L1 2 Safety Line 3/8 27.00 - 1.0000 1.0000 57.00 L1 11 3" Flex Conduit 41.00 - 1.0000 1.0000 48.50 Discrete Tower Loads Description Face Offset Offsets: Azimuth Placement CA CA Weight AAAA or Type Horz AdjustmenFront Side Leg Lateral t Vert 22 ft ft ft ft K ft ° ft Platform Mount \[LP 601-1\] C None 0.0000 57.00 No Ice 28.47 28.47 1.12 1/2'' 33.59 33.59 1.51 Ice Side Arm Mount \[SO 701-C None 0.0000 57.00 No Ice 2.83 2.83 0.20 3\] 1/2'' 3.92 3.92 0.24 Ice SBNHH-1D65C w/ Mount A From Leg 4.00 0.0000 57.00 No Ice 11.59 9.79 0.10 Pipe 0.00 1/2'' 12.31 11.31 0.19 3.00 Ice SBNHH-1D65C w/ Mount B From Leg 4.00 0.0000 57.00 No Ice11.59 9.79 0.10 Pipe 0.00 1/2'' 12.31 11.31 0.19 3.00 Ice SBNHH-1D65C w/ Mount C From Leg 4.00 0.0000 57.00 No Ice11.59 9.79 0.10 Pipe 0.00 1/2'' 12.31 11.31 0.19 3.00 Ice (2) 742 265 w/ Mount PipeA From Leg 4.00 0.0000 57.00 No Ice7.85 6.41 0.08 0.00 1/2'' 8.45 7.63 0.14 0.00 Ice (2) 742 265 w/ Mount PipeB From Leg 4.00 0.0000 57.00 No Ice7.85 6.41 0.08 0.00 1/2'' 8.45 7.63 0.14 0.00 Ice (2) 742 265 w/ Mount Pipe C From Leg 4.00 0.0000 57.00 No Ice 7.85 6.41 0.08 0.00 1/2'' 8.45 7.63 0.14 0.00 Ice tnxTower Report - version 6.1.4.1 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 11 Description Face Offset Offsets: Azimuth Placement CA CA Weight AAAA or Type Horz Adjustmen Front Side Leg Lateral t Vert 22 ft ft ft ft K ft ° ft 3JR52703AAAA w/ Mount A From Leg 4.00 0.0000 57.00 No Ice 11.60 13.66 0.15 Pipe 0.00 1/2'' 12.22 15.11 0.26 3.00 Ice 3JR52703AAAA w/ Mount B From Leg 4.00 0.0000 57.00 No Ice 11.60 13.66 0.15 Pipe 0.00 1/2'' 12.22 15.11 0.26 3.00 Ice 3JR52703AAAA w/ Mount C From Leg 4.00 0.0000 57.00 No Ice 11.60 13.66 0.15 Pipe 0.00 1/2'' 12.22 15.11 0.26 3.00 Ice RRH4X25-WCS A From Leg 4.00 0.0000 57.00 No Ice 4.45 3.81 0.09 0.00 1/2'' 4.77 4.11 0.13 3.00 Ice RRH4X25-WCS B From Leg 4.00 0.0000 57.00 No Ice 4.45 3.81 0.09 0.00 1/2'' 4.77 4.11 0.13 3.00 Ice RRH4X25-WCS C From Leg 4.00 0.0000 57.00 No Ice 4.45 3.81 0.09 0.00 1/2'' 4.77 4.11 0.13 3.00 Ice RRH2X40-07L-DE A From Leg 4.00 0.0000 57.00 No Ice 4.00 2.56 0.07 0.00 1/2'' 4.29 2.81 0.10 3.00 Ice RRH2X40-07L-DE B From Leg 4.00 0.0000 57.00 No Ice 4.00 2.56 0.07 0.00 1/2'' 4.29 2.81 0.10 3.00 Ice RRH2X40-07L-DE C From Leg 4.00 0.0000 57.00 No Ice 4.00 2.56 0.07 0.00 1/2'' 4.29 2.81 0.10 3.00 Ice (2) LGP21401 A From Leg 4.00 0.0000 57.00 No Ice 1.29 0.23 0.01 0.00 1/2'' 1.45 0.31 0.02 3.00 Ice (2) LGP21401 B From Leg 4.00 0.0000 57.00 No Ice 1.29 0.23 0.01 0.00 1/2'' 1.45 0.31 0.02 3.00 Ice (2) LGP21401 C From Leg 4.00 0.0000 57.00 No Ice 1.29 0.23 0.01 0.00 1/2'' 1.45 0.31 0.02 3.00 Ice RRH 2x60W-1900MHz A From Leg 4.00 0.0000 57.00 No Ice 2.19 1.41 0.04 0.00 1/2'' 2.40 1.59 0.06 3.00 Ice RRH 2x60W-1900MHz B From Leg 4.00 0.0000 57.00 No Ice 2.19 1.41 0.04 0.00 1/2'' 2.40 1.59 0.06 3.00 Ice RRH 2x60W-1900MHz C From Leg 4.00 0.0000 57.00 No Ice 2.19 1.41 0.04 0.00 1/2'' 2.40 1.59 0.06 3.00 Ice 9442 RRH 700 W/SOLAR A From Leg 4.00 0.0000 57.00 No Ice 2.49 2.21 0.05 0.00 1/2'' 2.71 2.42 0.07 0.00 Ice 9442 RRH 700 W/SOLAR B From Leg 4.00 0.0000 57.00 No Ice 2.49 2.21 0.05 0.00 1/2'' 2.71 2.42 0.07 3.00 Ice 9442 RRH 700 W/SOLAR C From Leg 4.00 0.0000 57.00 No Ice 2.49 2.21 0.05 0.00 1/2'' 2.71 2.42 0.07 0.00 Ice (2) KRY 112 71/2 A From Leg 4.00 0.0000 57.00 No Ice 0.68 0.45 0.01 0.00 1/2'' 0.80 0.56 0.02 0.00 Ice (2) KRY 112 71/2 B From Leg 4.00 0.0000 57.00 No Ice 0.68 0.45 0.01 0.00 1/2'' 0.80 0.56 0.02 0.00 Ice (2) KRY 112 71/2 C From Leg 4.00 0.0000 57.00 No Ice 0.68 0.45 0.01 0.00 1/2'' 0.80 0.56 0.02 0.00 Ice DC6-48-60-18-8F A From Leg 4.00 0.0000 57.00 No Ice 2.57 2.57 0.02 0.00 1/2'' 2.80 2.80 0.04 3.00 Ice DC6-48-60-18-8F B From Leg 4.00 0.0000 57.00 No Ice 2.57 2.57 0.02 0.00 1/2'' 2.80 2.80 0.04 3.00 Ice tnxTower Report - version 6.1.4.1 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 12 Description Face Offset Offsets: Azimuth Placement CA CA Weight AAAA or Type Horz Adjustmen Front Side Leg Lateral t Vert 22 ft ft ft ft K ft ° ft (4) 860 10025 A From Leg 4.00 0.0000 57.00 No Ice 0.16 0.14 0.00 0.00 1/2'' 0.23 0.20 0.00 3.00 Ice (4) 860 10025 B From Leg 4.00 0.0000 57.00 No Ice 0.16 0.14 0.00 0.00 1/2'' 0.23 0.20 0.00 3.00 Ice (4) 860 10025 C From Leg 4.00 0.0000 57.00 No Ice 0.16 0.14 0.00 0.00 1/2'' 0.23 0.20 0.00 3.00 Ice *** Side Arm Mount \[SO 104-C None 0.0000 41.00 No Ice 3.30 3.30 0.29 3\] 1/2'' 4.13 4.13 0.32 Ice Pipe Mount \[PM 601-3\] C None 0.0000 40.00 No Ice 4.39 4.39 0.20 1/2'' 5.48 5.48 0.24 Ice 840 10054 w/ Mount Pipe A From Leg 2.00 0.0000 41.00 No Ice 6.48 3.66 0.08 0.00 1/2'' 7.31 4.75 0.13 1.00 Ice 840 10054 w/ Mount Pipe B From Leg 2.00 0.0000 41.00 No Ice 6.48 3.66 0.08 0.00 1/2'' 7.31 4.75 0.13 1.00 Ice 840 10054 w/ Mount Pipe C From Leg 2.00 0.0000 41.00 No Ice 6.48 3.66 0.08 0.00 1/2'' 7.31 4.75 0.13 1.00 Ice DAP Vx RF A From Leg 2.00 0.0000 41.00 No Ice 2.27 2.27 0.03 0.00 1/2'' 2.51 2.51 0.05 -3.00 Ice DAP Vx RF B From Leg 2.00 0.0000 41.00 No Ice 2.27 2.27 0.03 0.00 1/2'' 2.51 2.51 0.05 -3.00 Ice DAP Vx RF C From Leg 2.00 0.0000 41.00 No Ice 2.27 2.27 0.03 0.00 1/2'' 2.51 2.51 0.05 -3.00 Ice Tower Forces - No Ice - Wind Normal To Face Section Add Self F e C q D D A F w Ctrl. FzFRE Elevation Weight Weight a Face c psf 2 ft K K e ft K plf L1 57.00-0.34 1.02 A 1 118 11 43.1190.87 29.071 C 27.00 B 1 111 43.119 C 1 111 43.119 L2 27.00-0.25 1.78 A 1 115 11 51.7490.85 31.488 C 0.00 B 1 111 51.749 C 111151.749 Sum Weight: 0.59 2.79 OTM 47.05 kip-1.72 ft Tower Forces - No Ice - Wind 60 To Face Section Add Self Fe CqDDAF w Ctrl. FzFRE Elevation Weight Weight a Face c psf 2 ft K K e ft K plf L1 57.00-0.34 1.02 A 1 118 11 43.1190.87 29.071 C 27.00 B 1 111 43.119 tnxTower Report - version 6.1.4.1 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 13 Section Add Self F e C q D D A F w Ctrl. FzFRE Elevation Weight Weight a Face c psf 2 ft K K e ft K plf C 1 111 43.119 L2 27.00-0.25 1.78 A 1 115 11 51.7490.85 31.488 C 0.00 B 1 111 51.749 C 1 111 51.749 Sum Weight: 0.59 2.79 OTM 47.05 kip-1.72 ft Tower Forces - No Ice - Wind 90 To Face Section Add Self F e C q D D A F w Ctrl. FzFRE Elevation Weight Weight a Face c psf 2 ft K K e ft K plf L1 57.00-0.34 1.02 A 1 118 11 43.1190.90 30.084 B 27.00 B 1 1.03511 43.119 C 1 111 43.119 L2 27.00-0.25 1.78 A 1 115 11 51.7490.85 31.488 C 0.00 B 1 111 51.749 C 1 111 51.749 Sum Weight: 0.59 2.79 OTM 48.30 kip-1.75 ft Tower Forces - With Ice - Wind Normal To Face Section Add Self F e C q D D A F w Ctrl. FzFRE Elevation Weight Weight a Face c psf 2 ft K K e ft K plf L1 57.00-0.40 1.35 A 1 1.22 11 45.6760.14 4.603 C 27.00 B 1 1.211 45.676 C 1 1.211 45.676 L2 27.00-0.28 2.13 A 1 1.22 11 54.0500.13 4.916 C 0.00 B 1 1.211 54.050 C 1 1.211 54.050 Sum Weight: 0.68 3.47 OTM 7.43 kip-ft0.27 Tower Forces - With Ice - Wind 60 To Face Section Add Self Fe CqDDAF w Ctrl. FzFRE Elevation Weight Weight a Face cpsf 2 ft K K e ftKplf L1 57.00-0.40 1.35 A 1 1.22 11 45.6760.14 4.603 C 27.00B 11.21145.676 C 1 1.211 45.676 L2 27.00-0.28 2.13 A 1 1.22 11 54.0500.13 4.916 C 0.00B 11.21154.050 C 1 1.211 54.050 Sum Weight: 0.68 3.47 OTM 7.43 kip-ft0.27 Tower Forces - With Ice - Wind 90 To Face tnxTower Report - version 6.1.4.1 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 14 Section Add Self F e C q D D A F w Ctrl. FzFRE Elevation Weight Weight a Face c psf 2 ft K K e ft K plf L1 57.00-0.40 1.35 A 1 1.22 11 45.6760.14 4.603 C 27.00 B 1 1.211 45.676 C 1 1.211 45.676 L2 27.00-0.28 2.13 A 1 1.22 11 54.0500.13 4.916 C 0.00 B 1 1.211 54.050 C 1 1.211 54.050 Sum Weight: 0.68 3.47 OTM 7.43 kip-ft0.27 Tower Forces - Service - Wind Normal To Face Section Add Self F e C q D D A F w Ctrl. FzFRE Elevation Weight Weight a Face c psf 2 ft K K e ft K plf L1 57.00-0.34 1.02 A 1 18 11 43.1190.39 12.961 C 27.00 B 1 111 43.119 C 1 111 43.119 L2 27.00-0.25 1.78 A 1 17 11 51.7490.38 14.038 C 0.00 B 1 111 51.749 C 1 111 51.749 Sum Weight: 0.59 2.79 OTM 20.97 kip-0.77 ft Tower Forces - Service - Wind 60 To Face Section Add Self F e C q D D A F w Ctrl. FzFRE Elevation Weight Weight a Face c psf 2 ft K Ke ft K plf L1 57.00-0.34 1.02 A 1 18 11 43.1190.39 12.961 C 27.00 B 1 111 43.119 C 1 111 43.119 L2 27.00-0.25 1.78 A 1 17 11 51.7490.38 14.038 C 0.00 B 1 111 51.749 C 1 111 51.749 Sum Weight: 0.59 2.79 OTM 20.97 kip-0.77 ft Tower Forces - Service - Wind 90 To Face Section Add Self Fe CqDDAF w Ctrl. FzFRE Elevation Weight Weight a Face cpsf 2 ftKKe ftKplf L1 57.00-0.34 1.02 A 1 18 11 43.1190.40 13.412 B 27.00B 11.0351143.119 C 1 111 43.119 L2 27.00-0.25 1.78 A 1 17 11 51.7490.38 14.038 C 0.00B 111151.749 C 1 111 51.749 Sum Weight: 0.59 2.79 OTM 21.53 kip-0.78 ft tnxTower Report - version 6.1.4.1 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 15 Load Combinations Comb. Description No. 1 Dead Only 2 1.2 Dead+1.6 Wind 0 deg - No Ice 3 0.9 Dead+1.6 Wind 0 deg - No Ice 4 1.2 Dead+1.6 Wind 30 deg - No Ice 5 0.9 Dead+1.6 Wind 30 deg - No Ice 6 1.2 Dead+1.6 Wind 60 deg - No Ice 7 0.9 Dead+1.6 Wind 60 deg - No Ice 8 1.2 Dead+1.6 Wind 90 deg - No Ice 9 0.9 Dead+1.6 Wind 90 deg - No Ice 10 1.2 Dead+1.6 Wind 120 deg - No Ice 11 0.9 Dead+1.6 Wind 120 deg - No Ice 12 1.2 Dead+1.6 Wind 150 deg - No Ice 13 0.9 Dead+1.6 Wind 150 deg - No Ice 14 1.2 Dead+1.6 Wind 180 deg - No Ice 15 0.9 Dead+1.6 Wind 180 deg - No Ice 16 1.2 Dead+1.6 Wind 210 deg - No Ice 17 0.9 Dead+1.6 Wind 210 deg - No Ice 18 1.2 Dead+1.6 Wind 240 deg - No Ice 19 0.9 Dead+1.6 Wind 240 deg - No Ice 20 1.2 Dead+1.6 Wind 270 deg - No Ice 21 0.9 Dead+1.6 Wind 270 deg - No Ice 22 1.2 Dead+1.6 Wind 300 deg - No Ice 23 0.9 Dead+1.6 Wind 300 deg - No Ice 24 1.2 Dead+1.6 Wind 330 deg - No Ice 25 0.9 Dead+1.6 Wind 330 deg - No Ice 26 1.2 Dead+1.0 Ice+1.0 Temp 27 1.2 Dead+1.0 Wind 0 deg+1.0 Ice+1.0 Temp 28 1.2 Dead+1.0 Wind 30 deg+1.0 Ice+1.0 Temp 29 1.2 Dead+1.0 Wind 60 deg+1.0 Ice+1.0 Temp 30 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp 31 1.2 Dead+1.0 Wind 120 deg+1.0 Ice+1.0 Temp 32 1.2 Dead+1.0 Wind 150 deg+1.0 Ice+1.0 Temp 33 1.2 Dead+1.0 Wind 180 deg+1.0 Ice+1.0 Temp 34 1.2 Dead+1.0 Wind 210 deg+1.0 Ice+1.0 Temp 35 1.2 Dead+1.0 Wind 240 deg+1.0 Ice+1.0 Temp 36 1.2 Dead+1.0 Wind 270 deg+1.0 Ice+1.0 Temp 37 1.2 Dead+1.0 Wind 300 deg+1.0 Ice+1.0 Temp 38 1.2 Dead+1.0 Wind 330 deg+1.0 Ice+1.0 Temp 39 Dead+Wind 0 deg - Service 40 Dead+Wind 30 deg - Service 41 Dead+Wind 60 deg - Service 42 Dead+Wind 90 deg - Service 43 Dead+Wind 120 deg - Service 44 Dead+Wind 150 deg - Service 45 Dead+Wind 180 deg - Service 46 Dead+Wind 210 deg - Service 47 Dead+Wind 240 deg - Service 48 Dead+Wind 270 deg - Service 49 Dead+Wind 300 deg - Service 50 Dead+Wind 330 deg - Service Maximum Tower Deflections - Service Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. ° ° L1 57 - 27 9.003 50 1.4146 0.0049 L2 30 - 0 2.501 44 0.7694 0.0012 Critical Deflections and Radius of Curvature- Service Wind tnxTower Report - version 6.1.4.1 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 16 Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ° ° ft 57.00 Platform Mount \[LP 601-1\] 50 9.003 1.4146 0.0049 7824 41.00 Side Arm Mount \[SO 104-3\] 50 4.762 1.0364 0.0025 2445 40.00 Pipe Mount \[PM 601-3\] 50 4.526 1.0125 0.0023 2301 Maximum Tower Deflections - Design Wind Section Elevation Horz. Gov. Tilt Twist No. Deflection Load ft in Comb. ° ° L1 57 - 27 32.432 24 5.1006 0.0176 L2 30 - 0 9.014 24 2.7750 0.0042 Critical Deflections and Radius of Curvature- Design Wind Elevation Appurtenance Gov. Deflection Tilt Twist Radius of Load Curvature ft Comb. in ° ° ft 57.00 Platform Mount \[LP 601-1\] 24 32.432 5.1006 0.0176 2194 41.00 Side Arm Mount \[SO 104-3\] 24 17.161 3.7382 0.0088 684 40.00 Pipe Mount \[PM 601-3\] 24 16.310 3.6518 0.0084 643 Compression Checks Pole Design Data Section Elevation Size L LKl/r A PRatio P f u u n No. P u 2 ft ft ft in K K P f n L1 57 - 55.5789 TP19.82x13.5x0.1875 30.00 0.00 0.0 8.2182 -3.64 605.76 0.006 55.5789 - 8.3989 -3.70 619.08 0.006 54.1579 54.1579 - 8.5796 -3.77 632.41 0.006 52.7368 52.7368 - 8.7604 -3.85 645.73 0.006 51.3158 51.3158 - 8.9411 -3.92 659.05 0.006 49.8947 49.8947 - 9.1219 -4.00 672.37 0.006 48.4737 48.4737 - 9.3026 -4.08 685.70 0.006 47.0526 47.0526 - 9.4834 -4.17 699.02 0.006 45.6316 45.6316 - 9.6641 -4.25 712.34 0.006 44.2105 44.2105 - 9.8449 -4.34 725.66 0.006 42.7895 42.7895 - 10.025-4.43 735.01 0.006 41.3684 6 41.3684 - 10.206-5.43 743.97 0.007 39.9474 3 39.9474 - 10.387-5.53 752.78 0.007 38.5263 1 38.5263 - 10.567-5.63 761.45 0.007 37.1053 8 37.1053 - 10.748-5.73 769.95 0.007 35.6842 6 35.6842 - 10.929-5.83 778.31 0.007 tnxTower Report - version 6.1.4.1 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 17 Section Elevation Size L LKl/r A PRatio P f u u n No. P u 2 ft ft ft in K K P f n 34.2632 3 34.2632 - 11.110-5.93 786.51 0.008 32.8421 1 32.8421 - 11.290-6.04 794.57 0.008 31.4211 8 31.4211 - 30 11.471-6.15 802.47 0.008 6 30 - 27 11.853-2.85 818.65 0.003 1 L2 30 - 27 TP25x18.813x0.25 30.00 0.00 0.0 15.441-3.69 1138.18 0.003 3 27 - 25.5789 15.677-6.66 1155.57 0.006 2 25.5789 - 15.913-6.79 1172.96 0.006 24.1579 1 24.1579 - 16.149-6.92 1190.34 0.006 22.7368 0 22.7368 - 16.384-7.05 1207.73 0.006 21.3158 9 21.3158 - 16.620-7.18 1225.12 0.006 19.8947 9 19.8947 - 16.856-7.31 1242.51 0.006 18.4737 8 18.4737 - 17.092-7.45 1259.90 0.006 17.0526 7 17.0526 - 17.328-7.58 1277.29 0.006 15.6316 6 15.6316 - 17.564-7.72 1293.65 0.006 14.2105 5 14.2105 - 17.800-7.86 1305.54 0.006 12.7895 5 12.7895 - 18.036-8.01 1317.28 0.006 11.3684 4 11.3684 - 18.272-8.15 1328.88 0.006 9.94737 3 9.94737 - 18.508-8.29 1340.32 0.006 8.52632 2 8.52632 - 18.744-8.44 1351.63 0.006 7.10526 2 7.10526 - 18.980-8.59 1362.79 0.006 5.68421 1 5.68421 - 19.216-8.74 1373.80 0.006 4.26316 0 4.26316 - 19.451-8.89 1384.67 0.006 2.84211 9 2.84211 - 19.687-9.04 1395.39 0.006 1.42105 8 1.42105 - 0 19.923-9.19 1405.97 0.007 7 Pole Bending Design Data Section Elevation Size MRatio MRatio MM ff ux uy nx ny No. MM ux uy ft kip-ft kip-ft kip-ft kip-ft MM ff nxny L1 57 - 55.5789 TP19.82x13.5x0.1875 20.89 167.01 0.125 0.00 167.01 0.000 55.5789 - 30.75 174.49 0.176 0.00 174.49 0.000 54.1579 54.1579 - 40.69 182.13 0.223 0.00 182.13 0.000 52.7368 52.7368 - 50.72 189.94 0.267 0.00 189.94 0.000 51.3158 51.3158 - 60.84 197.91 0.307 0.00 197.91 0.000 49.8947 49.8947 - 71.04 206.04 0.345 0.00 206.04 0.000 48.4737 48.4737 - 81.32 214.34 0.379 0.00 214.34 0.000 47.0526 47.0526 - 91.69 222.80 0.412 0.00 222.80 0.000 tnxTower Report - version 6.1.4.1 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 18 Section Elevation Size MRatio MRatio MM ff ux uy nx ny No. M M ux uy ft kip-ft kip-ft kip-ft kip-ft M M ff nxny 45.6316 45.6316 - 102.15 231.43 0.441 0.00 231.43 0.000 44.2105 44.2105 - 112.72 240.21 0.469 0.00 240.21 0.000 42.7895 42.7895 - 123.38 247.82 0.498 0.00 247.82 0.000 41.3684 41.3684 - 134.78 255.42 0.528 0.00 255.42 0.000 39.9474 39.9474 - 146.87 263.07 0.558 0.00 263.07 0.000 38.5263 38.5263 - 159.05 270.78 0.587 0.00 270.78 0.000 37.1053 37.1053 - 171.32 278.54 0.615 0.00 278.54 0.000 35.6842 35.6842 - 183.67 286.34 0.641 0.00 286.34 0.000 34.2632 34.2632 - 196.11 294.20 0.667 0.00 294.20 0.000 32.8421 32.8421 - 208.64 302.09 0.691 0.00 302.09 0.000 31.4211 31.4211 - 30 221.26 310.03 0.714 0.00 310.03 0.000 30 - 27 110.67 326.90 0.339 0.00 326.90 0.000 L2 30 - 27 TP25x18.813x0.25 137.56 442.54 0.311 0.00 442.54 0.000 27 - 25.5789 261.15 456.25 0.572 0.00 456.25 0.000 25.5789 - 274.15 470.17 0.583 0.00 470.17 0.000 24.1579 24.1579 - 287.22 484.31 0.593 0.00 484.31 0.000 22.7368 22.7368 - 300.37 498.65 0.602 0.00 498.65 0.000 21.3158 21.3158 - 313.59 513.20 0.611 0.00 513.20 0.000 19.8947 19.8947 - 326.89 527.96 0.619 0.00 527.96 0.000 18.4737 18.4737 - 340.26 542.93 0.627 0.00 542.93 0.000 17.0526 17.0526 - 353.72 558.11 0.634 0.00 558.11 0.000 15.6316 15.6316 - 367.25 573.04 0.641 0.00 573.04 0.000 14.2105 14.2105 - 380.86 586.16 0.650 0.00 586.16 0.000 12.7895 12.7895 - 394.54 599.36 0.658 0.00 599.36 0.000 11.3684 11.3684 - 408.31 612.63 0.666 0.00 612.63 0.000 9.94737 9.94737 - 422.16 625.98 0.674 0.00 625.98 0.000 8.52632 8.52632 - 436.09 639.39 0.682 0.00 639.39 0.000 7.10526 7.10526 - 450.10 652.87 0.689 0.00 652.87 0.000 5.68421 5.68421 - 464.19 666.41 0.697 0.00 666.41 0.000 4.26316 4.26316 - 478.36 680.01 0.703 0.00 680.01 0.000 2.84211 2.84211 - 492.62 693.67 0.710 0.00 693.67 0.000 1.42105 1.42105 - 0 506.96 707.39 0.717 0.00 707.39 0.000 Pole Shear Design Data Section Elevation Size Actual Ratio Actual Ratio VT ff n n No. VVTT u u u u ft K kip-ft K kip-ft V T ff nn L1 57 - 55.5789 TP19.82x13.5x0.1875 6.90 302.88 0.023 0.21 338.65 0.001 55.5789 - 6.97 309.54 0.023 0.21 353.82 0.001 54.1579 tnxTower Report - version 6.1.4.1 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 19 Section Elevation Size Actual Ratio Actual Ratio VT ff n n No. VVTT u u u u ft K kip-ft K kip-ft V T ff nn 54.1579 - 7.03 316.20 0.022 0.21 369.31 0.001 52.7368 52.7368 - 7.09 322.86 0.022 0.00 385.14 0.000 51.3158 51.3158 - 7.15 329.53 0.022 0.00 401.30 0.000 49.8947 49.8947 - 7.21 336.19 0.021 0.00 417.79 0.000 48.4737 48.4737 - 7.27 342.85 0.021 0.00 434.61 0.000 47.0526 47.0526 - 7.33 349.51 0.021 0.00 451.77 0.000 45.6316 45.6316 - 7.41 356.17 0.021 0.42 469.26 0.001 44.2105 44.2105 - 7.47 362.83 0.021 0.42 487.08 0.001 42.7895 42.7895 - 7.54 367.50 0.021 0.42 502.51 0.001 41.3684 41.3684 - 8.49 371.99 0.023 0.42 517.91 0.001 39.9474 39.9474 - 8.55 376.39 0.023 0.42 533.43 0.001 38.5263 38.5263 - 8.61 380.72 0.023 0.42 549.05 0.001 37.1053 37.1053 - 8.67 384.98 0.023 0.42 564.79 0.001 35.6842 35.6842 - 8.73 389.15 0.022 0.42 580.62 0.001 34.2632 34.2632 - 8.79 393.26 0.022 0.42 596.54 0.001 32.8421 32.8421 - 8.86 397.28 0.022 0.42 612.55 0.001 31.4211 31.4211 - 30 8.92 401.23 0.022 0.42 628.64 0.001 30 - 27 4.09 409.32 0.010 0.19 662.86 0.000 L2 30 - 27 TP25x18.813x0.25 4.99 569.09 0.009 0.23 897.33 0.000 27 - 25.5789 9.13 577.78 0.016 0.42 925.13 0.000 25.5789 - 9.18 586.48 0.016 0.42 953.37 0.000 24.1579 24.1579 - 9.23 595.17 0.016 0.42 982.02 0.000 22.7368 22.7368 - 9.29 603.87 0.015 0.42 1011.10 0.000 21.3158 21.3158 - 9.34 612.56 0.015 0.42 1040.61 0.000 19.8947 19.8947 - 9.39 621.26 0.015 0.42 1070.54 0.000 18.4737 18.4737 - 9.45 629.95 0.015 0.42 1100.89 0.000 17.0526 17.0526 - 9.50 638.65 0.015 0.42 1131.68 0.000 15.6316 15.6316 - 9.56 646.83 0.015 0.42 1161.95 0.000 14.2105 14.2105 - 9.61 652.77 0.015 0.42 1188.55 0.000 12.7895 12.7895 - 9.67 658.64 0.015 0.42 1215.32 0.000 11.3684 11.3684 - 9.73 664.44 0.015 0.42 1242.22 0.000 9.94737 9.94737 - 9.78 670.16 0.015 0.42 1269.28 0.000 8.52632 8.52632 - 9.84 675.82 0.015 0.42 1296.47 0.000 7.10526 7.10526 - 9.90 681.39 0.015 0.42 1323.81 0.000 5.68421 5.68421 - 9.96 686.90 0.014 0.42 1351.27 0.000 4.26316 4.26316 - 10.01 692.34 0.014 0.42 1378.85 0.000 2.84211 2.84211 - 10.07 697.70 0.014 0.42 1406.56 0.000 1.42105 1.42105 - 0 10.13 702.98 0.014 0.42 1434.38 0.000 tnxTower Report - version 6.1.4.1 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 20 Pole Interaction Design Data Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria No. PMMVTStress Stress u ux uy u u ft Ratio Ratio P M M V T fffff nnxnynn L1 57 - 55.5789 0.006 0.125 0.000 0.023 0.001 0.132 1.000 4.8.2 55.5789 - 0.006 0.176 0.000 0.023 0.001 0.183 1.000 4.8.2 54.1579 54.1579 - 0.006 0.223 0.000 0.022 0.001 0.230 1.000 4.8.2 52.7368 52.7368 - 0.006 0.267 0.000 0.022 0.000 0.273 1.000 4.8.2 51.3158 51.3158 - 0.006 0.307 0.000 0.022 0.000 0.314 1.000 4.8.2 49.8947 49.8947 - 0.006 0.345 0.000 0.021 0.000 0.351 1.000 4.8.2 48.4737 48.4737 - 0.006 0.379 0.000 0.021 0.000 0.386 1.000 4.8.2 47.0526 47.0526 - 0.006 0.412 0.000 0.021 0.000 0.418 1.000 4.8.2 45.6316 45.6316 - 0.006 0.441 0.000 0.021 0.001 0.448 1.000 4.8.2 44.2105 44.2105 - 0.006 0.469 0.000 0.021 0.001 0.476 1.000 4.8.2 42.7895 42.7895 - 0.006 0.498 0.000 0.021 0.001 0.504 1.000 4.8.2 41.3684 41.3684 - 0.007 0.528 0.000 0.023 0.001 0.536 1.000 4.8.2 39.9474 39.9474 - 0.007 0.558 0.000 0.023 0.001 0.566 1.000 4.8.2 38.5263 38.5263 - 0.007 0.587 0.000 0.023 0.001 0.595 1.000 4.8.2 37.1053 37.1053 - 0.007 0.615 0.000 0.023 0.001 0.623 1.000 4.8.2 35.6842 35.6842 - 0.007 0.641 0.000 0.022 0.001 0.649 1.000 4.8.2 34.2632 34.2632 - 0.008 0.667 0.000 0.022 0.001 0.675 1.000 4.8.2 32.8421 32.8421 - 0.008 0.691 0.000 0.022 0.001 0.699 1.000 4.8.2 31.4211 31.4211 - 30 0.008 0.714 0.000 0.022 0.001 0.722 1.000 4.8.2 30 - 27 0.003 0.339 0.000 0.010 0.000 0.342 1.000 4.8.2 L2 30 - 27 0.003 0.311 0.000 0.009 0.000 0.314 1.000 4.8.2 27 - 25.5789 0.006 0.572 0.000 0.016 0.000 0.578 1.000 4.8.2 25.5789 - 0.006 0.583 0.000 0.016 0.000 0.589 1.000 4.8.2 24.1579 24.1579 - 0.006 0.593 0.000 0.016 0.000 0.599 1.000 4.8.2 22.7368 22.7368 - 0.006 0.602 0.000 0.015 0.000 0.608 1.000 4.8.2 21.3158 21.3158 - 0.006 0.611 0.000 0.015 0.000 0.617 1.000 4.8.2 19.8947 19.8947 - 0.006 0.619 0.000 0.015 0.000 0.625 1.000 4.8.2 18.4737 18.4737 - 0.006 0.627 0.000 0.015 0.000 0.633 1.000 4.8.2 17.0526 17.0526 - 0.006 0.634 0.000 0.015 0.000 0.640 1.000 4.8.2 tnxTower Report - version 6.1.4.1 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 21 Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria No. PMMVTStress Stress u ux uy u u ft Ratio Ratio P M M V T fffff nnxnynn 15.6316 15.6316 - 0.006 0.641 0.000 0.015 0.000 0.647 1.000 4.8.2 14.2105 14.2105 - 0.006 0.650 0.000 0.015 0.000 0.656 1.000 4.8.2 12.7895 12.7895 - 0.006 0.658 0.000 0.015 0.000 0.665 1.000 4.8.2 11.3684 11.3684 - 0.006 0.666 0.000 0.015 0.000 0.673 1.000 4.8.2 9.94737 9.94737 - 0.006 0.674 0.000 0.015 0.000 0.681 1.000 4.8.2 8.52632 8.52632 - 0.006 0.682 0.000 0.015 0.000 0.689 1.000 4.8.2 7.10526 7.10526 - 0.006 0.689 0.000 0.015 0.000 0.696 1.000 4.8.2 5.68421 5.68421 - 0.006 0.697 0.000 0.014 0.000 0.703 1.000 4.8.2 4.26316 4.26316 - 0.006 0.703 0.000 0.014 0.000 0.710 1.000 4.8.2 2.84211 2.84211 - 0.006 0.710 0.000 0.014 0.000 0.717 1.000 4.8.2 1.42105 1.42105 - 0 0.007 0.717 0.000 0.014 0.000 0.723 1.000 4.8.2 Section Capacity Table Elevation Component Size Critical P øP% Pass S ection allow ft Type Element K K Capacity Fail No. L1 57 - 27 Pole TP19.82x13.5x0.1875 1 -6.15 802.47 72.2 Pass L2 27 - 0 Pole TP25x18.813x0.25 2 -9.19 1405.97 72.3 Pass Summary ELC: LC 5 Pole (L2) 72.3 Pass Rating = 72.3 Pass tnxTower Report - version 6.1.4.1 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 22 APPENDIX B BASE LEVEL DRAWING tnxTower Report - version 6.1.4.1 57 ft Monopole Tower Structural Analysis September 17 2014 Project Number 2014777.840470.01, Application 255122, Revision 9 CCI BU No 840470 Page 23 APPENDIX C ADDITIONAL CALCULATIONS tnxTower Report - version 6.1.4.1 Moment Capacity of Drilled Concrete Shaft (Caisson) for TIA Rev F or G Note: Shaft assumed to have ties, not spiral, transverse reinforcing Site DataMaximum Shaft Superimposed Forces 840470 TIA Revision: BU #:G Lake Ballinger Max. Factored Shaft Mu: Site Name:558.00 ft-kips (Note) 255122 Rev. 9 Max. Factored Shaft Pu: Application #:9kips Max Axial Force Type: Comp. Note: Max shaft superimposed moment does not necessarily Loads Already Factored Note: equal the shaft top reaction moment. <--- Disregard For M (WL)1.3 <--- Disregard Shaft Factored Loads For P (DL)1.3Load Factor 1.0Mu:558ft-kips Pier Properties 1.0Pu:9kips Concrete: Pier Diameter =Material Properties 4.5ft 2 Concrete Compressive Strength, f = Concrete Area = 2290.24000psi in c Reinforcement Yield Strength, F = 60ksi y Reinforcement:Reinforcing Modulus of Elasticity, E = 29000ksi Clear Cover to Tie =Reinforcement Yield Strain = 4.00in0.00207 Horizontal Tie Bar Size =Limiting Compressive Strain = 5 0.003 Vertical Cage Diameter =ACI 318 Code 3.65ft Vertical Cage Diameter =Select Analysis ACI Code = 43.75in2008 Vertical Bar Size =Seismic Properties 8 Bar Diameter =Seismic Design Category = 1.00in B 2 Bar Area =Seismic Risk = 0.79 Low in Number of Bars = 16 2 A Total= 12.64 in S SOLVE (RUN) <--- Press Upon Completing All Input A/ A (Rho) = 0.00550.55% s conc. ACI 10.5 , ACI 21.10.4, and IBC 1810. Results: Min As for Flexural, Tension Controlled, Shafts:Governing Orientation Case: 1 (3)*Sqrt(f) / F = 0.0032 cy 200 / F = 0.0033 y Case 1Case 2 Distance From Edge to Neutral Axis = in 7.88 Extreme Steel Strain, = 0.0156 t Minimum Rho Check:t > 0.0050, Tension Controlled Actual Req'd Min. Rho =Reduction Factor, = 0.33%Flexural 0.9 Provided Rho = 0.55% OK Ref. Shaft Max Axial Capacities, Max(Pn or Tn): Output Note: Negative Pu = Tension Max Pu = (=0.65)*Pn. Pn per ACI 318 (10-2) For Axial Compression, *Pn = Pu = 4421.13kips 9.00kips at Mu = (=0.65)*Mn =Drilled Shaft Moment Capacity, *Mn = 1703.92ft-kips 1279.00 ft-kips Drilled Shaft Superimposed Mu = 558.00 ft-kips Max Tu, (=0.9)*Tn = 682.56kips 0.00ft-kips at Mu = (=0.90)*Mn =(Mu / *Mn, Drilled Shaft Flexure CSR =43.6% Drilled_Shaft_Moment_Capacity, DSMC, Version 1.1 - Effective 04/01/ 2010Analysis Date: 9/17/2014