Loading...
F-2.12 Site Details.pdfE 0 N N 0 ao i D m o� 0 0 0 0 W Q E 0 01 0 a 3 .o iu 0 N N 'ED IN AT :TIC TURF ERIMETER �► 12 OR 15" - 0.5" 45` — TOOLED EDGE CHAMFER (TYP.) 2.5" CLR 4 ° p ALTERNATE D p P I oD ® EXPANSION JOINT — AND WEAKENED I o PLAN/CONTROL #4 REBAR ° JOINT AT EACH CONTINUOUS POST. CONCRETE PAVING JOINTS TO © PLAN VIEW ALIGN WITH OF 12 OR 15" FENCE POSTS O r 0.5" 45° CHAMFER WHERE INCLUDED. B '4 a° a a Qa. a — " #4 REBAR 3/8 IMPREGNATED CONTINUOUS FIBER BOARD @ ALL h -NiLOCATIONS, FULL DEPTH FENCE POST OA SECTION LOCATE (2) CONTINUOUS LOCATIONS #4 BAR WITHIN THE BOTTOM 30% OF THE © ELEVATION CONTAINMENT CURB CURB MASS PROVIDE ADEQUATE COVER CHAINLINK 1 FENCE F-2.5 I / I / D ° p 2.5" CLR O D . ° TOOLED EDGE �o 0 (TYP.) ° o #4 REBAR LOCATE (2) CONTINUOUS CONTINUOUS #4 BAR OE PLAN VIEW a WITHIN THE BOTTOM 30% OF THE CURB a MASS PROVIDE FENCE POST a ADEQUATE COVER O 0.5" 45° CHAMFER Oa p 12a � E " � o � a � da OR 12 OR 15" I 1" CLR. 11 �a a a 15" f o a o � � p a MIN. 3" o o � o a � a O SECTION L► AT FENCE POSTS 1 CONCRETE CURB &EXPANSION JOINT F-2.12j NOT TO SCALE INFILL MATERIAL TO BE FLUSH WITH TOP OF CONCRETE CURB NOTCH CONCRETE TO EXTEND TURF TO FACE OF FENCE POST. ADHERE TURF BACKING TO CONCRETE SURFACE INFILLED SYNTHETIC ri_`��TURF (TYP.) F-2.1 SYNTHETIC TURF EDGE ANCHOR 2X4 RECYCLED PLASTIC TIMBER IN LENGTHS AS REQUIRED. SECURE RECYCLED PLASTIC TIMBER TO CONCRETE EDGE WITH APPROVED RAMSET NAIL. (SPACE 21 " MAX ON CENTER) EDGE ANCHOR AT CONCRETE CURB NOT TO SCALE 0.5" 45° CHAMFER o a CONTINUOUS CONC. I", dp d as a #4 REBAR CONTINUOUS @ PLAYFIELDS I FENCE POST FOOTING © ELEVATION CHAINLINK — FENCE POST CONCRETE CURB 3/8" IMPREGNATED FIBER BOARD @ ALL LOCATIONS, FULL DEPTH @ FENCE POST LOCATIONS WEDGE ANCHOR POWER LOAD/ RAM -SET 4 SYNTHETIC TURF EDGE ANCHOR F-2.12j NOT TO SCALE IN OUT OF PLAY PLAY FLAG: 1-1/2" X 11GA. MILD STEEL A36 FLATTENED EXPANDED SHEET OUTFIELD FENCING LINE POST FENCE FABRIC CONCRETE CURB FOUL POLE INTERGATED AS TERMINAL POST FOUL POLE FOOTING VI EW ?"-4" CLEAR OF TOP RAIL 6 OUTFIELD SIGN F-2.12 FENCE RAIL WITH CAP 7 (COLOR TBD) F-2.12 SET GROUND SLEEVE FLUSH WITH TOP OF CONCRETE CURB 5 FOUL POLE CONCRETE CURB TO BE FLUSH �F�-2.12 NOT TO SCALE WITH ADJACENT SURFACE ADJACENT SURFACE MAY VARY NOTES: 1. THE PLASTIC EDGE ANCHOR MAY BE TEMPORARILY SET WITH POWER -LOADS PLACED AT THE CONTRACTORS OPTION TO ASSIST IN ESTABLISHING THE PROPER LINE AND GRADE. THIS TEMPORARY HARDWARE MAY REMAIN AFTER FINAL INSTALLATION. 2. THE CONTRACTOR MAY CHOOSE TO UTILIZE STEEL POWER -LOAD DRIVEN OR RAM -SET CONCRETE ANCHOR NAILS, MINIMUM SHANK DIAMETER 5/32", MINIMUM HEAD/WASHER DIAMETER 3/8", SUFFICIENT LENGTH TO INSURE A MINIMUM 2" EMBEDMENT. INDIVIDUAL ANCHORS SHALL DEVELOP A MINIMUM 450LB SHEAR, 350LB TENSION IN 4,000PSI CONCRETE AT 2" EMBEDMENT. 3. ONCE INITIAL LINE AND GRADE HAS BEEN ESTABLISHED, INSTALL THE SPECIFIED RAM -SET OR POWER -LOAD DRIVEN CONCRETE ANCHORING NAILS IN MANNER CONSISTENT WITH THE APPROVED MANUFACTURERS PRINTED INSTRUCTION AND THE SPECIFIED SPACING. 4. WEDGE ANCHOR TO BE SET AT MIDDLE 50% OF EACH BOARD. 30" O.C. MAX., 4-6" FROM ENDS. 5. MINIMUM REQUIREMENTS FOR CONCRETE ANCHOR NAIL INSTALLATION DEPTH OF EMBEDMENT: 2" OR AS RECOMMENDED BY THE ANCHOR SUPPLIER, WHICHEVER IS GREATER. HORIZONTAL SPACING: NO GREATER THAN 21 " ON CENTER AND 6" FROM END OF ANY LENGTH OF LUMBER. STAGGER THE SPACING OF EACH ANCHOR UP AND DOWN WITHIN THE MIDDLE ONE-HALF THE FACE OF THE RECYCLED EDGE ANCHOR. 21" 21" 21" f (TYP) (TYP) —f (TYP) 6„ UPPER 25% l — — — — — — — — — — — — —41— — — — — — — — — 1 MIDDLE 50% ♦---------♦--------------- } f LOWER 25% FAIR FOUL (IN PLAY) TERRITORY 2' MIN 25' MIN. FOUL POLE: 4" O.D. PAINTED 5 YELLOW F-2.12 SCH 40 GALVANIZED INSTALL FOUL POLE AS A TERMINAL POST IN OUTFIELD FENCE 3' 111 GROUND-1 SLEEVE a �II a ,a ELEVATION OUTFIELD 1 FENCING F_2.9 FINISHED GRADE SURFACE VARIES FENCE LINE CURB 24" DIA. 5' DEEP CONCRETE FOOTING �Y 18 GAUGE ALUMINUM 4-YEAR VINYL BACKGROUND (2) #4 CONTINUOUS & GRAPHICS HOG RING SIGN TO OUTFIELD 24" MIN FENCE FABRIC METAL SIGN WITH GREEN BACKGROUND AND 12" MIN. WHITE NUMBERS. FENCE POST FOOTING NOTE: ALTERNATE TOOLED JOINTS AND EXPANSION 18" JOINTS 10' O.C. • MIN 6 OUFIELD SIGNS F-2.12j NOT TO SCALE LOCATION: BASEBALL FIELD LEFT FIELD FOUL LINE 315' CENTER FIELD 385' RIGHT FIELD FOUL LINE 315' TERMINATE FENCE CAP AT TERMINAL POSTS. CAP TO BE CONTINOUS AT 10' HEIGHT POST 4" DIAMETER POLYURETHANE SLIT PIPE FENCE CAP (COLOR TBD) TOP RAIL AT OUTFIELD FENCE OUTFIELD PERIMETER FENCING INSTALL FENCE CAP AT ALL OUTFIELD PERIMETER FENCE FENCE CAP NOT TO SCALE FENCE POST SECTION FENCEI CAP REVISION DATE LD:MOti I SCH(IDL D I S T R I C T ts EDMONDS WOO DWAY SYNTHETIC TURF CONVERSION DI.. AN 119 1st Avenue South, Suite 110 p. 206.285.0400 Seattle, Washington 98104 f. 206.285.0480 O V W AS S 71 R C r � 2� IQ) V . S 6\ 5+ �8 Ex P .011 Cq PE AEG DATE 2-9-2018 SCALE NTS DRAWN JCH CHECKED RSH COPYRIGHT O 2017 D.A. HOGAN & ASSOCIATES SITE DETAILS SHEET F-2,12