Loading...
F-2.2 Drainage Details.pdfSURFACE VARIES LOCKING CAST IRON FRAME & GRATE (18" X 24") a 26" GROUT ALL PIPE a WATERTIGHT ON BOTH SIDES OF CATCH BASIN (TYP. ) kH CPEP COLLECTOR PIPE (SEE DRAINAGE PLAN FOR INVERTS) 18" MIN PRECAST CONCRETE C.B.I.I INTERNAL DIMENSIONS= 26" L X 22"W X 40"D - I 1 F-2.2 4" a a a a 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7 11*1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 III III III 34» II III TYPE 1 CATCH BASIN NOT TO SCALE SLOPE To DRAIN ADJUSTMENT RISER(S) AS REQUIRED 4" MIN. GROUT 6" GRAVEL NOTE: FOR INVERT ELEVATIONS SEE DRAINAGE SHEET A FLOW INLET TOP SLAB ACCESS SEE FRAME AND COVER DETAIL CONTRACTOR TO GROUT TO FINISHED GRADE GRADE RING/RISERS INLET PIPE FILTE 2 F-2.2 OUTLET SUMP PLAN VIEW STANDARD OUTLET RISER FLOWKIT: 40A 48" I.D. MANHOLE STRUCTURE (58") O.D. STORMFILTER DESIGN NOTES STORMFILTER TREATMENTCAPACITY IS A FUNCTION OF THE CARTRIDGE SELECTION AND THE NUMBER OF CARTRIDGES. THE STANDARD MANHOLE STYLE IS SHOWN WITH THE MAXIMUM NUMBER OF CARTRIDGES (7). VOLUME SYSTEM IS ALSO AVAILABLE WITH MAXIMUM 7 CARTRIDGES. 072" MANHOLE STORMFILTER PEAK HYDRAULIC CAPACITY IS 1.5 CFS. IF THE SITE CONDITIONS EXCEED 1.5 CFS AN UPSTREAM BYPASS STRUCTURE IS REQUIRED. CARTRIDGE SELECTION CARTRIDGE HEIGHT 27" 18" LOW DROP RECOMMENDED HYDRAULIC DROP (H) 3.05' 2.3' 1.8' SPECIFIC FLOW RATE (gpm/sf) 2 gpm/ft2 1 gpm/ft2 2 gpm/ftz 1 1 gpm/ft2 2 gpm/ft2 1 gpm/ft2 CARTRIDGE FLOW RATE (gpm) 22.5 11.25 15 7.5 1 10 GENERAL NOTES 1. CONTECH TO PROVIDE ALL MATERIALS UNLESS NOTED OTHERWISE. 2. DIMENSIONS MARKED WITH ( ) ARE REFERENCE DIMENSIONS. ACTUAL DIMENSIONS MAY VARY. 3. FOR SITE SPECIFIC DRAWINGS WITH DETAILED VAULT DIMENSIONS AND WEIGHTS, PLEASE CONTACT YOUR CONTECH ENGINEERED SOLUTIONS LLC REPRESENTATIVE. www.contechES.com 4. STORMFILTER WATER QUALITY STRUCTURE SHALL BE IN ACCORDANCE WITH ALL DESIGN DATA AND INFORMATION CONTAINED IN THIS DRAWING. 5. STRUCTURE SHALL MEET AASHTO HS20 LOAD RATING, ASSUMING EARTH COVER OF 0' - 5' AND GROUNDWATER ELEVATION AT, OR BELOW, THE OUTLET PIPE INVERT ELEVATION. ENGINEER OF RECORD TO CONFIRM ACTUAL GROUNDWATER ELEVATION. CASTINGS SHALL MEET AASHTO M306 AND BE CAST WITH THE CONTECH LOGO. 6. FILTER CARTRIDGES SHALL BE MEDIA -FILLED, PASSIVE, SIPHON ACTUATED, RADIAL FLOW, AND SELF CLEANING. RADIAL MEDIA DEPTH SHALL BE 7-INCHES. FILTER MEDIA CONTACT TIME SHALL BE AT LEAST 39 SECONDS. >ATABLES 7. SPECIFIC FLOW RATE IS EQUAL TO THE FILTER TREATMENT CAPACITY (gpm) --FLE DIVIDED BY THE FILTER CONTACT SURFACE AREA (sq ft). INSTALLATION NOTES 1. ANY SUB -BASE, BACKFILL DEPTH, AND/OR ANTI -FLOTATION PROVISIONS ARE SITE -SPECIFIC DESIGN CONSIDERATIONS AND SHALL BE SPECIFIED BY ENGINEER OF RECORD. 2. CONTRACTOR TO PROVIDE EQUIPMENT WITH SUFFICIENT LIFTING AND REACH CAPACITY TO LIFT AND SET THE STORMFILTER STRUCTURE (LIFTING CLUTCHES INSIDE HEIGHT PROVIDED). 6' TYPICAL 3. CONTRACTOR TO INSTALL JOINT SEALANT BETWEEN ALL STRUCTURE SECTIONS AND ASSEMBLE STRUCTURE. 4. CONTRACTOR TO PROVIDE, INSTALL, AND GROUT INLET PIPE(S). iYDRAULIC DRO 5. CONTRACTOR TO PROVIDE AND INSTALL CONNECTOR TO THE OUTLET RISER STUB. (H) INLEMS11BY. HEIGHT STORMFILTER EQUIPPED WITH A DUAL DIAMETER HDPE OUTLET STUB AND SAND TO OUTLET' INCYYPICAL COLLAR. IF OUTLET PIPE IS LARGER THAN 8 INCHES, CONTRACTOR TO REMOVE THE 8 INCH OUTLET STUB AT MOLDED IN CUT LINE. COUPLING BY FERNCO OR EQUAL AND PROVIDED BY CONTRACTOR. 6. CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT CARTRIDGES FROM CONSTRUCTION -RELATED EROSION RUNOFF. UU I LE I SUMP HDPE OUTLET RISER SECTION A -A STORM WATER FILTER STRUCTURE NOT TO SCALE 0\/ ° V. 0 1 1 ° Id ° d CONCRETE WALL 6 F-2.10 0O4.I ` L �0 0 I �• ° 1 ° EXPANSION TOOLED O I I JOINT EDGE 0 dl� 0.625" DRAINAGE SLOT ACO SPORT 61 2000 CHANNEL 0 0 1 I ° 4 o a 41 ° 4 0 I I ° 61) _ d d b a I° a )� 0 ° 12" 4 ° I dI d l ° ° ° 0 oo) a I• ° i a - 6" O O) d O° I 1 °; a d I° ° ° a ° 4 d ° a Q d °... °- 41 d 4 ° a 4 d° a a 1 1 _ d 1 ° °° 1 a 4_1116d - - 3 F-2.2 SLOT DRAIN NOT TO SCALE ACRYLIC TENNIS 3 COURT PAVING 3" ASPHALT PAVING (2 LIFTS) 6" BASE COURSE PERMEABLE AGGREGATE COMPACTED SUBGRADE CONCRETE SITE SPECIFIC DATA REQUIREMENTS STRUCTURE ID CB#2 WATER QUALITY FLOW RATE (cfs) 0.051 PEAK FLOW RATE (cfs) 0.308 RETURN PERIOD OF PEAK FLOW (yrs) 100-YR CARTRIDGE HEIGHT (27", 18", LOW DROP(LD)) LID NUMBER OF CARTRIDGES REQUIRED 3 CARTRIDGE FLOW RATE 8.35 MEDIA TYPE (PERLITE, ZPG, PSORB) PSORB PIPE DATA: I.E. MATERIAL DIAMETER INLET PIPE #1 411.05 CPEP 12" INLET PIPE #2 OUTLET PIPE 409.25 CPEP 12" RIM ELEVATION 417.30 ANTI -FLOTATION BALLAST WIDTH HEIGHT N/A N/A NOTES/SPECIAL REQUIREMENTS: * PER ENGINEER OF RECORD 4 d �0O I. d [• I. CONCRETE WALL 6 d I a F-2., o ° i EXPANSION 1 a' 4 d 1 JOINT a 0 I a 1 d 1 a I a TOOLED EDGE 0O ° I a I 0.625" DRAINAGE SLOT3 ACO SPORT 0 O) I I 2000 CHANNEL F-2.2 11 ° 14 < 1 6.1 O fill ° d d O° ° 6" ° 6" ° a 4 ° 4 � O ° ILL 'q d 20.75" ° d O I ° ° d ° O °1 4 a ° O ° 1 ° 00 I � I °° ° ° O d DOd d d 4 ° ° d d d� 4 ° ° ° d °. Q 4 ° %° d 4 ° 4 d 0 4 ° ° ° 4° a d ° ° ° 4 d 4 ° 4 a a ° ° 4 F-2.2 SLOT DRAIN CATCH BASIN NOT TO SCALE a 4 ° d 4 4 ° 4 d boo � 00 3 F-2.1 ACRYLIC TENNIS COURT PAVING 3" ASPHALT PAVING (2 LIFTS) 6" BASE COURSE PERMEABLE AGGREGATE CONCRETE COMPACTED SUBGRADE -III REVISION DATE ts SCEML D 1 S l R EDMONDS WOO DWAY SYNTHETIC TURF CONVERSION D A H C)'G A N 119 1st Avenue South, Suite 110 p. 206.285.0400 Seattle, Washington 98104 f. 206.285.0480 F WAS S HA �O o cj 2�S 76 EXP.01�1 Cq FE ARG DATE 2-9-2018 SCALE NTS DRAWN JCH CHECKED RSH COPYRIGHT (D2017 D.A. HOGAN & ASSOCIATES DRAINAGE DETAILS SHEET F-2,2