F-2.4 Detention Details.pdf0 P2 n ao I J N I 0 0 0 3 0 0 0 a D 4) 0 a rn 3 v N `o a� 0 0 -2 N L� N Lz 1 F-2.4 2 F-2.4 STORMTECH SC-740 OR APPROVED EQUAL POLYETHYLENE (PE) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS" EL 412.00 CHAMBER EL 411.50 6" ADS GEOSYNTHETIC 601T NON -WOVEN GEOTEXTILE ALL AROUND CLEAN, CRUSHED ANGULAR STONE I 18" MIN PEA GRAVEL-3/8" - TO J" WASHED INFILLED SYNTHETIC TURF 00�0�00�� 6" MIN. IA lrll I rn ("VA ITI IrTI f' TI Inl- DRAINAGE LATERAL (TYP.) 2 F-2.3 1" WASHED GRAVEL PER AASHTO M43 #57 0 A_C�C on;_wOonO�o n =III I� 51" 6" MIN. 51" STORM TECH CHAMBER SECTION FINISH GRADE 12" MIN. 1 INFILLED SYNTHETIC TURF UOO�OUOO�OUOO�OUOO��J- �J, 00c/00d/g000 0 0l 110l 11 0111)I • _��I i� �I i� �I i� �� i� ADS i,z_-+v) 3I urwiTECH SC-740 CHAMBER GEOSYNTHETICS OR APPROVED EQUAL POLYETHYLENE 601T NON -WOVEN (PE) CORRUGATED WALL GEOTEXTILE OR STORMWATER COLLECTION CHAMBERS APPROVED EQUAL STORM TECH CHAMBER ISOLATOR ROW 6" PVC SDR-35 Ll J U UNDERDRAIN PIPE OO 000 000 00 000 00 0 0 0 0 0 O 000 OO 00� 00��0 O� O� O� O��O� Oho Oho 0 0 0 0 000 O O (7j00 00�` O� O �O� � O O 0 O OO OO OO O O STORMTECH END CAP STORMTECH CHAMBER 6" FOUNDATION STONE BENEATH CHAMBER 1" WASHED GRAVEL PER AASHTO M43 #57 ADS GEOSYNTHETICS 601T 0 0o NON -WOVEN GEOTEXTILE OR ADS APPROVED EQUAL GEOSYNTHETICS 601T NON -WOVEN GEOTEXTILE OR SECTION A -A APPROVED EQUAL STORMTECH DETENTION CHAMBERS NOT TO SCALE PRE-FAB STUBS AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "B" PRE-FAB STUBS AT TOP OF END CAP FOR PART NUMBERS ENDING WITH "T" PRE -CORED END CAPS END WITH "PC" 30" FG 417.30 EXTEND GEOTEXTILE 18" MIN. PAST TRENCH WALL (BOTH SIDES) 6" MIN. STORMTECH END CAP 30" COVER ENTIRE ROW WITH ADS GEOSYNTHETIC 601T NON -WOVEN GEOTEXTILE -�00��0 �o o �o 0 ODOo �p0o 0 000OoDO000OoDO( 0�0 o1)0 oo0o 0 o O0000�00° 000 ho < a000 00 o�o^oo�o SECTION B-B TOP MANIFOLD BOTTOM MANIFOLD CONNECTION CONNECTION PART # STUB A B C SC740EPE06T / SC740EPE06TPC 6 (150 mm) 10.9 (277 mm) 18.5" (470 mm) --- SC740EPE06B / SC740EPE06BPC --- 0.5" (13 mm) SC740EPE08T /SC740EPE08TPC g (200 mm) 12.2" (310 mm) 16.5" (419 mm) --- SC740EPE08B / SC740EPE08BPC --- 0.6" (15 mm) SC740EPE10T / SC740EPE10TPC 10" (250 mm) 13.4" (340 mm) 14.5" (368 mm) --- SC740EPE10B / SC740EPE10BPC --- 0.7" (18 mm) SC740EPE12T / SC740EPE12TPC 12 (300 mm) 14.7 (373 mm) 12.5" (318 mm) --- SC740EPE1213 / SC740EPE12BPC --- 1.2" (30 mm) SC740EPE15T / SC740EPE15TPC 15" (375 mm) 18.4" (467 mm) 9.0" (229 mm) --- SC740EPE1513 / SC740EPE15BPC --- 1.3" (33 mm) SC740EPE18T / SC740EPE18TPC 18" (450 mm) 19.7" (500 mm) 5.0" (127 mm) --- SC740EPE1813 / SC740EPE18BPC --- 1.6" (41 mm) SC740EPE24B* 24" (600 mm) 18.5" (470 mm) --- 0.1" (3 mm) STORMTECH SC-740 MANIFOLD DETAIL NOT TO SCALE ALL STUBS, EXCEPT FOR THE SC740EPE24B ARE PLACED AT BOTTOM OF END CAP SUCH THAT THE OUTSIDE DIAMETER OF THE STUB IS FLUSH WITH THE BOTTOM OF THE END CAP. FOR ADDITIONAL INFORMATION CONTACT STORMTECH AT 1-888-892-2694. FOR THE SC740EPE24B THE 24" (600 mm) STUB LIES BELOW THE BOTTOM OF THE END CAP APPROXIMATELY 1.75" (44 mm). BACKFILL MATERIAL SHOULD BE REMOVED FROM BELOW THE N-12 STUB SO THAT THE FITTING SITS LEVEL. NOTE: ALL DIMENSIONS ARE NOMINAL 6" PVC SDR-35 UNDERDRAIN PIPE STORMTECH GENERAL NOTES: 1. CHAMBERS SHALL BE STORMTECH SC-740, OR APPROVED EQUAL. 2. CHAMBERS SHALL BE MANUFACTURED FROM VIRGIN POLYPROPYLENE OR POLYETHYLENE RESINS. 3. CHAMBER ROWS SHALL PROVIDE CONTINUOUS, UNOBSTRUCTED INTERNAL SPACE WITH NO INTERNAL SUPPORT PANELS THAT WOULD IMPEDE FLOW OR LIMIT ACCESS FOR INSPECTION. 4. THE STRUCTURAL DESIGN OF THE CHAMBERS, THE STRUCTURAL BACKFILL, AND THE INSTALLATION REQUIREMENTS SHALL ENSURE THAT THE LOAD FACTORS SPECIFIED IN THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, SECTION 12.12, ARE MET FOR: 1) LONG -DURATION DEAD LOADS AND 2) SHORT -DURATION LIVE LOADS, BASED ON THE AASHTO DESIGN TRUCK WITH CONSIDERATION FOR IMPACT AND MULTIPLE VEHICLE PRESENCES. 5. CHAMBERS SHALL MEET ASTM F2922 (POLYETHYLENE) OR ASTM F2418 (POLYPROPYLENE), "STANDARD SPECIFICATION FOR THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". 6. CHAMBERS SHALL BE DESIGNED AND ALLOWABLE LOADS DETERMINED IN ACCORDANCE WITH ASTM F2787, "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". 7. ONLY CHAMBERS THAT ARE APPROVED BY THE SITE DESIGN ENGINEER WILL BE ALLOWED. THE CHAMBER MANUFACTURER SHALL SUBMIT THE FOLLOWING UPON REQUEST TO THE SITE DESIGN ENGINEER FOR APPROVAL BEFORE DELIVERING CHAMBERS TO THE PROJECT SITE: a. A STRUCTURAL EVALUATION SEALED BY A REGISTERED PROFESSIONAL ENGINEER THAT DEMONSTRATES THAT THE SAFETY FACTORS ARE GREATER THAN OR EQUAL TO 1.95 FOR DEAD LOAD AND 1.75 FOR LIVE LOAD, THE MINIMUM REQUIRED BY ASTM F2787 AND BY AASHTO FOR THERMOPLASTIC PIPE. b. A STRUCTURAL EVALUATION SEALED BY A REGISTERED PROFESSIONAL ENGINEER THAT DEMONSTRATES THAT THE LOAD FACTORS SPECIFIED IN THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, SECTION 12.12, ARE MET. THE 50 YEAR CREEP MODULUS DATA SPECIFIED IN ASTM F2418 OR ASTM F2922 MUST BE USED AS PART OF THE AASHTO STRUCTURAL EVALUATION TO VERIFY LONG-TERM PERFORMANCE. C. STRUCTURAL CROSS SECTION DETAIL ON WHICH THE STRUCTURAL EVALUATION IS BASED. 8. CHAMBERS AND END CAPS SHALL BE PRODUCED AT AN ISO 9001 CERTIFIED MANUFACTURING FACILITY. 9. STORMTECH SC-740 CHAMBERS SHALL NOT BE INSTALLED UNTIL THE MANUFACTURER'S REPRESENTATIVE HAS COMPLETED A PRE -CONSTRUCTION MEETING WITH THE INSTALLERS. 10. STORMTECH SC-740 CHAMBERS SHALL BE INSTALLED IN ACCORDANCE WITH THE "STORMTECH SC-740 CONSTRUCTION GUIDE". 11. CHAMBERS ARE NOT TO BE BACKFILLED WITH A DOZER OR AN EXCAVATOR SITUATED OVER THE CHAMBERS. STORMTECH RECOMMENDS 3 BACKFILL METHODS: STONESHOOTER LOCATED OFF THE CHAMBER BED. BACKFILL AS ROWS ARE BUILT USING AN EXCAVATOR ON THE FOUNDATION STONE OR SUBGRADE. BACKFILL FROM OUTSIDE THE EXCAVATION USING A LONG BOOM HOE OR EXCAVATOR. 12. THE FOUNDATION STONE SHALL BE LEVELED AND COMPACTED PRIOR TO PLACING CHAMBERS. 13. JOINTS BETWEEN CHAMBERS SHALL BE PROPERLY SEATED PRIOR TO PLACING STONE. 14. MAINTAIN MINIMUM - 6" (150 mm) SPACING BETWEEN THE CHAMBER ROWS. 15. EMBEDMENT STONE SURROUNDING CHAMBERS MUST BE WSDOT PERMEABLE BALLAST AS APPROVED 16. THE CONTRACTOR MUST REPORT ANY DISCREPANCIES WITH CHAMBER FOUNDATION MATERIALS BEARING CAPACITIES TO THE SITE DESIGN ENGINEER. 17. PROTECT THE SYSTEM INSTALLATION FROM SEDIMENT LADEN INPUTS THROUGHOUT THE INSTALLATION AND TO FINAL ACCEPTANCE. 18. STORMTECH SC-740 CHAMBERS SHALL BE INSTALLED IN ACCORDANCE WITH THE "STORMTECH SC-740 CONSTRUCTION GUIDE". 19. THE USE OF CONSTRUCTION EQUIPMENT OVER SC-740 CHAMBERS IS LIMITED: NO EQUIPMENT IS ALLOWED ON BARE CHAMBERS. NO RUBBER TIRED LOADERS, DUMP TRUCKS, OR EXCAVATORS ARE ALLOWED UNTIL PROPER FILL DEPTHS ARE REACHED IN ACCORDANCE WITH THE "STORMTECH SC-740 CONSTRUCTION GUIDE". WEIGHT LIMITS FOR CONSTRUCTION EQUIPMENT CAN BE FOUND IN THE "STORMTECH SSC-740 CONSTRUCTION GUIDE". 20. FULL 36" (900 mm) OF STABILIZED COVER MATERIALS OVER THE CHAMBERS IS REQUIRED FOR DUMP TRUCK TRAVEL OR DUMPING. VERIFY WITH THE ENGINEERPRIOR TO INTRODUCING CONSTRCUTION TRAFFIC OVER THE WORK IN PROGRESS. STORMTECH STRUCTURAL NOTES: 21. THE EXPECTED SERVICE PERFORMANCE OF THE STORMTECH SC-740 AND SC-310 CHAMBERS USING ASTM F2787 AND AASHTO LRFD PROCEDURES FOR LOADS, STRUCTURAL CAPACITY, AND LOAD AND RESISTANCE FACTORS. ANALYSES WERE CONDUCTED USING CHAMBER GEOMETRY FROM THE STORMTECH SOLID COMPUTER GEOMETRIES CONFIRMED BY CHAMBER MEASUREMENTS AFTER MANUFACTURE. EVALUATION CONSISTED OF FINITE ELEMENT COMPUTER MODELING OF CHAMBER PERFORMANCE AT DEPTHS OF FILL BETWEEN 18 AND 96 INCHES, AND FIELD TEST WITH DEPTHS OF FILL BETWEEN 6 AND 138 INCHES. TIME -DEPENDENT MATERIAL PROPERTIES FOR THE POLYPROPYLENE CHAMBERS WERE BASED ON TESTS PERFORMED ON SPECIMENS FROM ACTUAL CHAMBERS. 22. THEIR ANALYSES AND CALCULATION DEMONSTRATE THAT THE FACTOR OF SAFETY IS EQUAL TO OR GREATER THAN 1.95 FOR DEAD LOAD AND 1.75 FOR LIVE LOAD, THE MINIMUM VALUES REQUIRED BY ASTM F2787 AND BY AASHTO FOR THERMOPLASTIC PIPE, WHEN INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE STORMTECH SC-310/SC-740/DC-780 DESIGN MANUAL AT DEPTHS OF FILL BETWEEN 18 AND 96 INCHES AND SUBJECTED TO LIVE LOADS OF DESIGN TRUCK (HS-20) MAGNITUDE OR LESS, INCLUDING ALLOWANCES FOR IMPACT AND MULTIPLE PRESENCE. IT IS SUGGESTED THAT THE MINIMUM DEPTH OF FILL BE INCREASED TO 24 INCHES FOR UNPAVED INSTALLATIONS, WHERE RUTTING MIGHT REDUCE THE DEPTH OF FILL OVER TIME." USE OF A DOZER TO PUSH EMBEDMENT STONE BETWEEN THE ROWS OF CHAMBERS MAY CAUSE DAMAGE TO THE CHAMBERS AND IS NOT AN ACCEPTABLE BACKFILL METHOD. ANY CHAMBERS DAMAGED BY THE "DUMP AND PUSH" METHOD ARE NOT COVERED UNDER THE STORMTECH STANDARD WARRANTY. CONTACT STORMTECH AT 1-888-892-2694 WITH ANY QUESTIONS ON INSTALLATION REQUIREMENTS OR WEIGHT LIMITS FOR CONSTRUCTION EQUIPMENT REVISION 1 )\10NDS SCHGDL 1)1S l R I C DATE EDMONDS WOO DWAY SYNTHETIC TURF CONVERSION DA H AN 119 1st Avenue South, Suite 110 p. 206.285.0400 Seattle, Washington 98104 f. 206.285.0480 OF WAS// S Hq O r � 20 0 V Cq PE ARG DATE 2-9-2018 SCALE NTS DRAWN JCH CHECI<ED RSH COPYRIGHT 02017 D.A. HOGAN &ASSOCIATES DETENTION DETAILS SHEET F-2A