F-2.5 Irrigation & Washwater Details.pdfREVISION DATE
E
a
0)
N
v
Ki
ao
i
0
0
0
0
Q
0
0
T
D
"0
0
a
3
.a
0
0
0
3
0
0
.91
Lq
N
1
F-2.5
RIM 418.97
1' MIN UNDER
FINISHED GRADE
PIPE SUPPORTS
PROVIDE AT AT LEAST ONE 3" x 0.090"
ALUMINUM SUPPORT BRACKET ANCHORED
TO CONCRETE WALL W/ 5/8" STAINLESS
BOLTS (MAX 3' SPACING)
HANDHOLDS, STEPS, OR
LADDER
12" WATER TIGHT SHEAR GATE WITH
CONTROL ROD FOR
CLEANOUT/DRAIN
12" INLET PIPE
8" OUTLET PIPE
CATCH BASIN TYPE
2-48" W/ SOLID COVER
FLOW CONTROL
NOT TO SCALE
6" MIN
II��a]
PLAN VIEW
roiiry �LLMRMw�E TO ANY
PORTION OF THE FLOW
CONTROL TEE
FRAME, GRATE, & SOLID
COVER MARKED "DRAIN" WITH
LOCKING BOLTS
PLAN VIEW
Z iwiiN �Lr_/ARMINCE TO ANY
PORTION OF THE FLOW
CONTROL TEE
FRAME, GRATE, & SOLID
COVER MARKED "DRAIN" WITH
LOCKING BOLTS
RIM 414.17F4
--- -
1' MIN UNDER - - - - -
FINISHED GRADE
MAX WS EL 416.80
6" MIN.
77 — —
w, -
N
PIPE SUPPORTS .
PROVIDE AT AT LEAST ONE 3" x 0.090"
ALUMINUM SUPPORT BRACKET ANCHORED
N a TO CONCRETE WALL W/ 5/8" STAINLESS
BOLTS (MAX 3' SPACING)
w
cn
12" INLET PIPE I I a
F4O8.50
+` Z ¢ N
HANDHOLDS, STEPS, OR
6 MAX 12" OUTLET PIPE LADDER CN CO
IE 411.09 IE 411.09 a Z
Q 12" WATER TIGHT SHEAR GATE WITH �'
-71
a
N CONTROL ROD FOR
`r °O 12" 0 SLEEVE - 6" MAX LENGTH CLEANOUT/DRAIN N p
a W/ TAPER FIT TO INSIDE 48'
Z DIAMETER OF OUTLET PIPE
N 0.9"0 RESTRICTOR ORIFICE IN
48" PLATE BOLTED TO FLANGE, OR
DRILLED CAP. CATCH BASIN TYPE
a 2-48" W/ SOLID COVER TYPE 2 CB-48"
TYPE 2 CB-48"
NOT TO SCALE
NOT TO SCALE
CINCH ANCHOR
WIRE ROPE CLIP -
(STAINLESS STEEL)
DEFORMED 3/8"
STEEL ROD (STAINLESS
STEEL OR ALUMINUM)
LENGTH TO FIT
PIPE AND CROS
FLOW CONTROL
STRUCTURE
PIPE SUPPORT
FLOW CONTROL
CMP RISER PIPE �� STRUCTURE
p.
NON -SHRINK GROUT
0
CONTROL DEVICE ASSEMBLY TO BE 1'-0"MAX COUPLING
REMOVABLE FROM PVC PIPE STUB
INSIDE THE FCS °- a -IF 7
I II II �
' " I II II II II
- - - -
0
GASKET (TYP)
0
e "�<
PVC ADAPTER W/ DOUBLE
ORIFICE GASKET AND ADHESIVE
CN O0 BONDED SAND FINISH ON
ORIFICE PLATE EXTERIOR. MIN 7" LONG
CAULK SPACE BETWEEN
PVC ADAPTER AND
PIPE STUB
CONNECTION AND CONTROL DEVICE
MAX WS EL 412.00
RECTANGULAR NOTCH WEIR
BTM EL 410.50
WEIR WIDTH 0.25"
" MAX 12" OUTLET PIPE
IE 408.50)
12"0 SLEEVE - 6" MAX LENGTH
W/ TAPER FIT TO INSIDE
DIAMETER OF OUTLET PIPE
0.5" 0 RESTRICTOR ORIFICE IN
PLATE BOLTED TO FLANGE, OR
DRILLED CAP.
2
F-2.5
POINT OF CONNECTION -SCHEMATIC
NOT TO SCALE
hD:M0'N' I )�
ts
SCHOOL
D I S T R I C T
EDMONDS
WOO DWAY
SYNTHETIC TURF
CONVERSION
L.. HOGAN
119 1st Avenue South, Suite 110 p. 206.285.0400
Seattle, Washington 98104 f. 206.285.0480
O V W A S,y
��T S. � Hq R ��C
P �� ��I V� 0 O
r �
2� oQ) V
S 6\
�65+ 78 EX P . 01
Cq PE AEG
DATE 2-9-2018
SCALE NTS
DRAWN JCH
CHECKED RSH
COPYRIGHT O 2017 D.A. HOGAN & ASSOCIATES
IRRIGATION &
WASHWATER
DETAILS
SHEET
F-2,5