Loading...
fire protection footprint 1.pdfDayton Condominiums 550 Dayton Street Occupancies: R1, U1 Type of construction: V 1-hour 2 stories with basement Total building area: 8,481 sf 1997 UBC, UFC, UPC, WSEC. VIAQ, State Barrier Free Code Fire Apparatus Access: Paved North and South Active Fire Protection Fire sprinkler system (UBC Standard 9-1) Fire sprinkler controls (Rm. 808) Illuminated exit signs Fire alarm system w/ smoke detectors & pull stations Emergency lighting w/ battery back-up Fire extinguishers Passive Fire Protection Smoke control system Escape windows from sleeping rooms Structural Protection Exterior load bearing walls: 1 hour Interior load bearing walls: 1 hour Structural frame: 1 hour Permanent partitions: 1 hour Shaft enclosures: 1 hour Floor -ceiling: 1 hour Roof -ceiling: 1 hour Exterior openings: N/A Stair enclosure: 1 hour Roof material: Class B LEGEND ---------+ ONE- 4OUR RASED WALL ASSEMBLY ► REQUIRED E)OT TO THE EXTERIOR OF 1HE BWLDING 86 - WK RATED SELF -CLOSING DOOR FIRE DEPARTMENT CONNECTION ELEVATOR FRONT LOBBY ENTRY ----------STAIRWELL i �� FTJRRACE/ `-' wAT�NTR. RM. I805I r---1 L--J r---I 1 J O r-� 1 1 I 1 L_1 L--� BOfXl DOM BASEMENT FLOOR PLAN FIRE PROTECTION FOOTPRINT Date prepared: Last Updated: Dayton Condominiums 550 Dayton Street Occupancies: R1, Ut Type of construction: V 1—hour 2 stories with basement Total building area: 8,481 sf 1997 UBC, UFC, UPC, WSEC, VIAQ, State Barrier Free Code Fire Apparatus Access: Paved North and South Active Fire Protection Fire sprinkler system (UBC Standard 9-1) Fire sprinkler controls (Rm. 908) Illuminated exit signs Fire alarm system w/ smoke detectors & pull stations Emergency lighting w/ battery back—up Fire extinguishers Passive Fire Protection Smoke control system Escape windows from sleeping rooms Structural Protection Exterior load bearing walls: 1 hour Interior load bearing walls: 1 hour Structural frame: 1 hour Permanent partitions: 1 hour Shaft enclosures: 1 hour Fioor—ceiling: 1 hour Roof —ceiling: 1 hour Exterior openings: N/A Stair enclosure: 1 hour Roof material: Class B LEGEND --------- ONE -HOUR RATED WALL ASSEMBLY . REQUIRED EXIT TO THE EXTERIOR OF THE BUILDING OA 60 - MIN. RATED SELF- LOSING DOOR FIRE DEPARTMENT CONNECTION na'ni ®FIRST FLOOR PLAN SCALE: 1/e'-P—O' UNIT 101 UNIT 102 FIRE PROTECTION FOOTPRINT Date prepared: Last Updated: Dayton Condominiums 550 Dayton Street Occupancies: Rt, U1 Type of construction: V 1—hour 2 stories with basement Total building area: 8,481 sf 1997 UBC, UFC, UPC, WSEC, MAO. State Barrier Free Code Fire Apparatus Access: Paved North and South Active Fire Protection Fire sprinkler system (UBC Standard 9-1) Fire sprinkler controls (Rm. 808) Illuminated exit signs Fire alarm system w/ smoke detectors & pull stations Emergency lighting w/ battery back—up Fire extinguishers Passive Fire Protection Smoke control system Escape windows from sleeping rooms Structural Protection Exterior load bearing walls: 1 hour Interior load bearing walls: 1 hour Structural frame: 1 hour Permanent partitions: 1 hour Shoft enclosures: 1 hour Floor —ceiling: 1 hour Roof —ceiling: i hour Exterior openings: N/A Stair enclosure: 1 hour Roof material: Class B LEGEND ---------+ ONE -HOUR RATED WALL ASSEMELY ' REOUM EbT TO THE EXTERIOR OF THE BUWNG OA 60 - MIN. RATED SELF -CLOSING DOOR FIE DEPARTMENT CONNECTION SECOND FLOOR PLAN SCALE: UNIT 201 UNIT 202 FIRE PROTECTION FOOTPRINT Date prepared: Last Updated: