Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
floor area.pdf
LEVEL 2 REFLECTED CEILING PLAN 1 /4" = 1'-0" N v V) Ln 0 E w PROJECT REFLECTED CEILING PLAN 1. EXISTING CEILINGS TO REMAIN UNLESS NOTED OTHERWISE. 2. CLEAN AND REPAIR EXISTING CEILING GRID AND TILES TO REMAIN WITHIN THE AREA OF WORK. REPLACE DAMAGED CEILING TILES WITH MATCHING BUILDING STANDARD TILES. 64Wr Jt5- 'K-VtO 3. LIGHT GAUGE METAL FRAMING SIZE, GAUGE AND SPACING AT SOFFITS AND CEILINGS TO MEET MANUFACTURER'S PUBLISHED SPAN TABLES, SPECIFIED DEFLECTION CRITERIA, AND TO SUPPORT BOTH GRAVITY AND LATERAL LOADS. 4. FOR TYPICAL ACP SUSPENDED CEILING DETAILS, SEE SHEET A7.00 5. REFLECTED CEILING PLANS SHOW GENERAL TYPE, LOCATION AND ORIENTATION OF LIGHTS, REGISTERS, DIFFUSERS AND OTHER CEILING MOUNTED ITEMS. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR MORE SPECIFIC REQUIREMENTS. 6. CENTER DOWNLIGHTS IN ACOUSTICAL TILE UNLESS NOTED OTHERWISE. 7. NOTE MECHANICAL AND ELECTRICAL DELEGATED DESIGN. 8. PROVIDE HVAC GRILLS, TRIM, SMOKE DETECTORS, COMMUNICATIONS AND ELECTRICAL DEVICES, RECESSED LIGHT FIXTURES AND OTHER CEILING MOUNTED DEVICES IN THE CENTER OF ACOUSTICAL CEILING TILES EXCEPT AS SPECIFICALLY NOTED OR SHOWN. 9. ALIGN HVAC GRILLS, DIFFUSERS, SMOKE DETECTORS, SPEAKERS AND OTHER CEILING MOUNTED DEVICES EXCEPT AS SPECIFICALLY NOTED OR SHOWN. a 10. P V E C UP C EN-- C OS S 0 1 11. IN EACH A EA OT EQU PP D WITH OCCUPAN Y S NSOR ,PROVIDE N TIME SWITCH CONTROLS PER WSEC C405.2.2 pr 12. MAINTAIN CONTINUITY OF RATED ROOF ASSEMBLY, PROVIDE W ADDITIONAL SUPPORT, BIDDER -DESIGNED, AS NECESSARY FOR INSTALLATION OF CEILING, INFRASTRUCTURE, AND LIGHTING. SEE 8/A7.00 FOR ADDITIONAL INFORMATION. REFLECTED CEILING PLAN KEYNOTES 1 CENTER CEILING GRID AND TILES IN ROOM. 2 ALIGN GRID WITH EDGE OF EXISTING SKYLIGHT 3 EXISTING SKYLIGHT, VERIFY SIZE AND LOCATION IN FIELD 4 REUSE EXISTING CEILING GRID, CEILING TILES, AND 2'X2' LIGHT FIXTURES WHERE POSSIBLE THIS SPACE, REPLACE ANY DAMAGED GRID AND TILE, MATCH EXISTING REFLECTED CEILING PLAN SYMBOLS El CONTROL SWITCH SURFACE MOUNTED FLUORESCENT STRIP LIGHT FIXTURE RECESSED CAN LIGHT FIXTURE 6" LED DOWNLIGHT HALO PD6_10_ED010= _PDM6A_835_61 V_H_-_HB128APK WALL MOUNT LINEAR VANITY FIXTURE EUREKA STROKE 3542-24 24", 3500K RECESSED 2'X2' LIGHT FIXTURE FINELITE HPR LED-EP_A_2x4_DCO_S_835_120V_SC_C1 RELOCATED EXISTING 2'X2' LIGHT FIXTURE EXIT LIGHT AC WITH BATTERY BACKUP AND DIRECTIONAL ARROW. UNITS WHERE LINE OF SIGHT TO NEAREST EXIT IS OBSCURED. GYP BOARD CEILING/ SOFFIT 2' X 2' CEILING GRID CERTAINTEED CEILINGS, CASHMERE, CLASS A REVEAL BEVELED PANELS, 15/16" GRID RESU B MAY 18 2010 WLDIW pEpARTMENT crty OF EDMOND6 6054 REGISTERED ARCHITECT '-J DAVEikETkONDO STATE OF WASHINGTON 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 T 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 T 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 T 415.252.7063 © ANKROM MOISAN ARCHITECTS, INC. CD N w D V) V N D W Q w af ~ W —i w N Q Z) C: Ln V Z 00 Q Q Q ILL]W Q � W z U V) Q p ono U G O O J 2 2 Q w W wry N �u..w 2 REVISION DATE REASON FOR ISSUE 1 5/17/18 PERMIT REV REFLECTED CEILING P LA N PERMIT SET DATE PROJECT NUMBER 03/22/18 162270