Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Former Woodway Revisions Memo 2-24-15.pdf
MEMORANDUM Date:February24,2015 To:CityofEdmondsPlanningDivision Copy:MattFinch,EdmondsPublicSchoolDistrict From:RobertHarding,DAHogan Re:FormerWoodwayHighSchoolFieldImprovements BelowisaresponsetothecorrectionsnoticedatedFebruary2,2015fromthePlanningDivision,Fire Marshall.ThecommentsarelistedalongwithresponsesfromtheApplicant. 1.Stripeand/orsignͻbƚParkingΑFire\[ğƓĻͼwhereindicated.PavedEmergencyAccessЋБor greatermayhaveparkingononeside.Provideapprovedemergencyaccessforgatesonsite. SeesheetF1.0.MarkingswereaddedoncurbinthefirelinetoindicateͻbƚtğƩƉźƓŭͼ͵Emergency Accessgateswillbeprovidedonsite. BelowisaresponsetothecorrectionsnoticesreceivedonDecember29,2014fromtheBuildingPlans Examiner.ThecommentsarelistedalongwithresponsesfromtheApplicant. 1.OnSheetF1.0: a.SiteOverviewProvideadetailindicatingtherequireddesignandconstructionperIBC 1604.1forthefieldlightingsupportbasesrepresentedatvariouslocationsaroundboth playfields.Workassociatedwiththeelectricalsystemforthefieldlightingistobe completedunderaseparatepermitobtainedthroughtheWashingtonStateDepartment ofLabor&Industries. RefertoelectricaldrawingsE1.1E2.3.Electricalisbeingsubmittedunderaseparate permit. 2.SheetF1.1,LayoutPlanΑSouthPhase1 a.Indicateontheplansthatthewalkwayrepresentedalongtheeastsideoftheplayfieldis connectedto,orwillprovide,therequiredaccessiblerouteperIBC1103.1. ThishasbeenindicatedonsheetF1.0. b.Indicateontheplansthatthebleachers/portablespectatorseatingrepresentedalongthe northsideandthesoutheastcorneroftheplayfieldcomplywithICC300perIBC1028.1.1. SeeDetail#7onsheetF2.7forthiscallout. c.IndicateontheplansthatanyteamorplayerseatingprovidedintheͷķǒŭƚǒƷƭ representedalongthenortheastandsoutheastcornersoftheplayfieldhaveatleastone wheelchairspacerequiredperIBC1108.2.2.4. SeeDetail#1onsheetF2.7forreferencetothewheelchairspaceprovided. D.A.Hogan&Associates,Inc.(206)2850400Tel 119FirstAve.S.,Suite110(206)2850480Fax Seattle,WA98104 BelowisaresponsetothecorrectionsnoticereceivedonDecember19,2014fromtheEngineering Division.ThecommentsarelistedalongwithresponsesfromtheApplicant. 1.PleaseaddnotetoerosionsedimentcontrolplansheetsF0.2andF0.2Aregardingthewet onpg11oftheAssociatedreport. weatherͻǞƚƩƉƭǒƩŅğĭĻͼrequirementdescribed Anotehasbeenaddedonbothsheetstoindicatethatadditionalinformationisincludedinthe specificationsinregardstoawetweatherͻǞƚƩƉƭǒƩŅğĭĻͼrequirement. 2.PleaseaddnotestodemoandgradingplansheetsstatingthatSpecialInspectionsbythegeotech ofrecordarerequiredfordeterminingsuitablesubgradeandstructuralfillpertheAssociated report. Thisnotehasbeenaddedtobothdemolitionandgradingplans. 3.AddnotetodrainageplansregardingtherequirementofSpecialInspectionfordrainage aggregatetestingasstatedintheAssociatedreport. Thisnotehasbeenaddedtothedrainageplanandindicatesreferencingboththespecification section334623forFieldPermeableAggregateaswellastheGeotechnicalReport. 4.AttachedisaSpecialInspectionsreportagreement.Pleasecompleteandreturnpriortopermit issuance. andsubmittedpriortopermitissuance. Thisreportagreementwillbecompleted 5.CB#5,shownonsheetF1.2,appearstobelocatedexactlywherethephase3Field House/Concessionsbuildingwillbeconstructed.Pleasereviselocationkeepinginmindthatthe futurebuildingdownspoutswillneedtoconnecttothestormsystem. Seerevisedstormdrainagedocument.Thisareawillbemodifiedwhenfuturebuildingplansare confirmed.Norevisionsarerequiredatthistime. 6.OnsheetF1.3,pleasedeterminetheoutletconnectionattheswcornerofthefieldandaddto plans. ThecatchbasinsanddrainlinespreviouslyshownaroundtheSWcornerofthefieldhavebeen replacedwithaFrenchdrainalongthesouthandsouthwesternedgeofthetrack.TheFrenchdrain isnowconnectedtothecatchbasinatthesouthendofthesyntheticturffield,atthestartofthe maincollectorlineforthefieldunderdrainsystem.Flowfromtheadjacentgrassareasintothe Frenchdrainwasnotconsideredinthestormwatermodelastheseareasareconsidereddisturbed perviouswithcompostamendedsoilsanddonothavetobemitigatedbyflowcontrol. StormwaterEngineerComments: StormwaterSitePlan Section4,page4Αalltheminimumrequirementshouldapplytotheconvertedpervioussurface asshowninthefigure.TheESCSTable44hasatypo.Disturbedpervioussurfacesshouldhave compostamendedsoils(asdescribedonpage6,minimumrequirement#5). beenupdatedintheStormwaterSitePlan.TheareaspreviouslynotedasͻķźƭƷǒƩĬĻķ Thishas ƦĻƩǝźƚǒƭͼarea(50%ofthefield,track,&perviouspavement)isnownotedasͻĭƚƓǝĻƩƷĻķƦĻƩǝźƚǒƭͼ area.ThegrassareaswithcompostamendedsoilsarereferredtoasͻķźƭƷǒƩĬĻķƦĻƩǝźƚǒƭͼsurfaces. Section4,page5ΑMinimumRequirement#2ΑTheproposedprojectdisturbsover1acre.A ConstructionStormwaterGeneralPermitfromtheDept.ofEcologyisrequired.Pleaseprovide theNoticeofIntent(NOI)forthispermit. TheNoticeofIntenthasbeencompletedandhasbeensubmittedwiththeresubmittalofthe reviseddrawingsandStormwaterSitePlan.TheNOIhasnotyetbeensenttotheDepartmentof EcologyaswearewaitingforthefinalSEPAdecision. Section4,page6ΑMinimumRequirement#8ΑTheCityacknowledgesthatunderthe2005 EcologyStormwaterManagementManualforWesternWashington(SWMMWW)turffieldssuch astheonesproposedforthisprojectarenotcalledoutaspollutiongeneratingimpervious surfaces(PGIS).Asyouknow,the2012versionoftheSWMMWWdoesclassifysyntheticturf fieldsasPGIS.Whilethesciencetosupportthisunclear,theCitydoeshavepotentialliability fromzinccontainingrunoffenteringitsstormwatersystem.Especiallyinthisparticularsituation wherethedischargefromthe/źƷǤƭstormwatersystemwilldischargeintoDeerCreek,adrinking watersourceforOlympicViewWater&SewerDistrict.UnderthesecircumstancestheCitywill requiretreatmentofthedischargefromtheproposedfieldpriortodischargingtothe/źƷǤƭ stormwatersystem. Section3.4,VolumeVofthe2005SWMMWW,providesamenuoftreatmentoptionfor dissolvedmetals.AsyoupointoutinyourNovember12,2014memorandum(fromNicole Hernandez,PEtoJerryShusterPE),abasicsandfiltervaultfollowedbyamediafilterwillmeet the2005SWMMWWrequirements.TheCitywouldapproveasystemthatjusthasasandfilter somedegreeofliabilitycoveragewithout vaultwithoutthemediafilter.Itwouldprovideuswith burdeningtheprojectwithexcessivecapitalorongoingmaintenancecosts. PeremailcorrespondencebetweenNicoleHernandezatLPDandJerryShusterattheCityof Edmonds,anStormFilterwithZPGmediaisproposedinsteadofthesandfilterassuggestedbythe StormFilterwillallowmoreflexibilityinfuturetreatmentoptionswithachangeinmedia City.The type,hasasmallerfootprint,andrequireslesselevationdropacrossthefilterallowingthe downstreamdrainagesystemtoremainshallower. Inaddition,correspondencebetweenNicoleHernandezandSteveDunphyatOlympicViewWater andSewerDistrict,confirmedthataslongash{5ƭdrinkingwaterintakeonDeerCreekisabove thedrainagedischargepoint(whichitisbelievedtobeandisbeingconfirmedbySteveDunphy), OVWSDdoesnothaveanyconcernsaboutprovidingwaterqualitytreatmentforthesyntheticturf field. PlanSheets SheetF1.1andF1.3ΑDoestheunderdrainsystemcapturerainfallthatinfiltratesthroughthe rubberizedtrack?Itshardtotellfromthedrawings,althoughithasbeenincludedinthe modelingcalculations. Yes,thetrackispermeableandthedrainagesystemextendsbelowthetrackareas. SheetF1.3ΑThereisnewpipingandcatchbasinsproposedfortheareassoutheastand southwestoftheproposedfields.Wheretotheseareasdischargeandhowweretheyaccounted forinthemodeling?Isthispartofthebypass? ThecatchbasinsanddrainlinespreviouslyshownaroundtheSWcornerofthefieldhavebeen replacedwithaFrenchdrainalongthesouthandsouthwesternedgeofthetrack.TheFrenchdrain isnowconnectedtothecatchbasinatthesouthendofthesyntheticturffield,atthestartofthe maincollectorlineforthefieldunderdrainsystem.Flowfromtheadjacentgrassareasintothe Frenchdrainwasnotconsideredinthestormwatermodelastheseareasareconsidereddisturbed perviouswithcompostamendedsoilsanddonothavetobemitigatedbyflowcontrol. SheetF2.1,Detail4,SeededSiteSoilRestorationΑReplacethenoteforͻͶƦƌğƓƷźƓŭƭƚźƌͼwith compostamendedsoilperEcologyBMPT5.13. Thenotehasbeenreplaced. SheetF2.1,Details5and8,RubberizedsurfacesectionandPerviousConcretePavingΑThe subgradeshouldNOTbecompactedunderporousasphaltorpreviousconcrete.Also,providea calloutforthetypeofrockthatwillbeusedinthepermeableaggregatebase.Whatisthe porosityoftherubberizedsurfacing? Aggregatebelowpavingisalsothepermeableaggregateandmustbecompactedforstability. Informationonpermeableaggregateisprovidedinspecificationsection334623.Theporosityof rubberizedsurfacingisindicatedasfollows.ForчͼofRubberizedsurfacinginfiltrationis approximatelyЋЉͼperhour. SheetF2.2,Detail4,FlowControlStructure(FCS)ΑThecitynolongeracceptssheargates.Please standarddetailE5.4foratheFCS(.dwgfileavailableat: useCity http://www.edmondswa.gov/services/permitsdevelopment/handoutsforms/servicespermits stddetailsmainpagemenu/servicesstddetailsstormdrainagesection5menu.html).Note thatthevnotchweirontopoftheriseinthedetailisnotrequired.Changeasneeded. inDetail4,themodelingusesariserheightof3.55feet.Detail4has3.45feetbetween Alsoin theoutletinvertandtherisertop.Pleasereconcile. ThedetailhasbeenupdatedtoreflectstandarddetailE5.4.Thesheargatehasbeentakenoff.The discrepancyinriserheightwasatypowithinthedetail.Ithasbeenupdatedtoariserheightof3.55 feet. Pleaseletmeknowifyouneedanyfurtherinformation. RobertHarding,Principal DAHogan&Associates,Inc. 2062850400p