Loading...
GEOTECH RESPONSE.pdf- muwww wu ",low N1111111011 SEP P. 2 2015 uRYW 1 1-bnGFj@ 0 C 0 0P 0 0 A T 0 0 Geotechnical & Earthquake Engineering Consultants April 27, 2015 File No. 13-063-100 Mr. Nicholas Echelbarger Salish Landing LLC PO BOX 1088 Edmonds, WA 98020 Subject: Response to Structural Review Comments Salish Pavilion — BLD2015-0294 150 Sunset Ave S Edmonds, WA Dear Mr. Echelbarger, This letter responds to review comments contained in the April 7, 2015, Correction Notice from the City of Edmonds, regarding the building plan set submitted for the proposed construction. Specific geotechnical responses to the Correction Notice are summarized below, with the numbering corresponding to that of the Correction Notice: Geotechnical 1. Geotechnical Report In response to the reviewer's request, PanGEO has prepared the attached geotechnical report for the proposed Pavilion Building dated April 27, 2015, which, as discussed below, addresses the requests for information by the City's reviewer. a) Seismic Lateral Earth Pressures The proposed building does not include a basement. Hence, there are no incremental seismic pressures acting on basement walls. 3213 Eastlake Avenue East Suite B Seattle, WA 98102-7127 Tel:(206) 262-0370 Fax:(206) 262-0374 Mr. Nicholas Echelbarger Response to Correction Notice 1 - Soils 150 Sunset Ave S — BLDG2015-0291 April 27, 2015 b) Potential for Liquefaction The site is underlain by compressible peat as well as loose to medium dense sand layers within the peat. The sand layers have a moderate susceptibility to liquefaction. c) Consequences of Liquefaction Static settlement of the peat as well as potential liquefaction induced settlement of the loose sand seams within the peat may result in several inches of differential settlement to structures supported on the ground surface. Consequently, pile foundations were recommended in the geotechnical report for the support of the building shell and associated interior and exterior floor slabs. d) Discussion of mitigation measures See response to c) above. e) IBC Section 1803.6 The April 27, 2015, geotechnical report addresses items identified in section 1803.6 of the IBC. f) Faults Although not mentioned by the reviewer, there are no known mapped faults located within 5 km of the site (see attached report). 2. Plan Review a) Plan Review We reviewed the January 30, 2015, structural plan set for the project and found that the drawings conform to the analysis and recommendations contained in PanGEO's report dated April 27, 2015. b) Summary Letter of Review See item 2 a) above. 13-063-100 150 Sunset Ave S CN1 Soils.doc 2 PanGEO, Inc. Mr. Nicholas Echelbarger Response to Correction Notice 1 - Soils 150 Sunset Ave S — BLDG2015-0291 April 27, 2015 We trust that the information outlined in this letter meets your need at this time. Please call if you have any questions. Sincerely, W. Paul Grant, P.E. Principal Geotechnical Engineer Encl. Appendix A — Geotechnical Report, Salish Pavilion — BLDG2015-0291, 150 Sunset Ave. S., Edmonds WA (PanGEO report dated April 27, 2015) 13-063-100 150 Sunset Ave S CN1 Soils.doc 3 PanGEO, Inc. APPENDIX A GEOTECHNICAL REPORT