Loading...
Gravity Bar Health Dist Approval Letter.pdfSNOHOMISH HEALTH DISTRICT WWW.SNOHD.ORG Environmental Health Division December 28, 2017 Elyssa Bo rd 22530 915 Avenue West Edmonds, WA 98026 Subject: Proposed Gravity Bar, 610 5th Avenue South #B, Edmonds Dear Ms. Boyd: Your plans have been reviewed with the Rules and Regulations of the State Board of Health, and with the policies of the Snohomish Health District. With the addition of the following conditions, the plans are approved. 1. The conditional approval of the plans for Gravity Bar was based upon the plans and menu submitted December 27, 2017 and HACCP submitted October 11, 2017. Any changes to these items will void this approval. 2. The Health District operating permit application process must be completed prior to opening for business. This facility will be classified as a medium risk food establishment with 13-50 seats. 3. Three -compartment sinks must be NSF or equivalent listed with rounded corners and integral drainboards at both ends. The basins of the three -compartment sink must be large enough to fit the largest item needing to be washed. 4. An indirect waste drain (an air gap) is required for the food preparation sink, sanitizer basin of the three -compartment sink, ice machine, and any equipment in which food is placed. Please note that a direct drain to a grease trap is not considered an indirect drain even if the grease trap is indirectly drained. 5. Food preparation sinks must be NSF or equivalent listed with at least one integral drainboard. 6. A horizontal separation of at least 16 inches or a vertical partition 16 inches in height is required between the handwash sink and all food preparation areas. 7. Water heaters must be of sufficient size to provide hot water to dishwasher and/or scullery sinks and at the same time provide hot water to all handwash sinks. 8. Hot water must be available to all handwash sinks within 15 seconds. The hot water for the facility must not be used, at any plumbing fixture, for a minimum of 6 hours prior to the preoperational inspection. This is required so that proper testing of the 15-second time requirement for hot water availability can be completed. 9. All food service equipment, both new and used, must be listed by the National Sanitation Foundation (NSF) or equivalent for its intended use. Used and new refrigeration must be capable of holding food at temperature of 41 OF or below. 10. Used equipment is subject to onsite inspection to determine acceptability for use in the proposed food service establishment. Used equipment must be clean, in proper operating condition, and in good repair. Used refrigeration must be capable of holding at a temperature of 41OF or below. 11. All food service equipment must be listed by the National Sanitation Foundation (NSF) or equivalent for its intended use. The Blendtec blender, model #Classic 560, the ALD bubble waffle maker, model #FY-6, the Miracle juicer, model #MJ445, the Miracle Pro Green juicer, model #MJ 575, and the Champions juicer, model #G5-PG710, were not found in the current NSF or equivalent listings. This equipment must be replaced with NSF or equivalent listed equipment or documentation must be submitted which demonstrates NSF equivalency. Manufacturer names and model numbers 3020 Rucker Avenue, Suite 104 ■ Everett, WA 98201-3900 0 tel: 425.339.5250 ■ fax: 425.339.5254 for replacement equipment or equipment documentation must be submitted prior to the request for a preoperational inspection. Originally submitted manufacturer names and model numbers should be rechecked to assure the information submitted is accurate. Please note that subsidiary manufacturers are often not found in the NSF and equivalent listings. The manufacturer name should be verified and submit the parent company name if one is found. 12. No manufacturer name or model number was submitted for the soup warmer or the shave ice machine. The manufacturer name and model number for this equipment must be submitted prior to the request for a preoperational inspection. 13. This facility has a limited amount of refrigeration equipment. If during routine inspections it is found that the current amount of refrigeration is inadequate for the refrigerated storage needs of the facility then the number of menu items must be reduced to a level acceptable for the facility's amount of refrigeration. The menu item reduction will remain in effect until such tirne as additional refrigeration is installed and approved by the Health District. 14. Extra wall protection is required on walls behind all sinks, including restroom handwash sinks, and food preparation counters and tables. Sinks in corners must also have wall protection on the side walls. A 16-inch high backsplash of plastic larninate, fiberglass -reinforced plastic or equal is acceptable. A backsplash higher than 16 inches is required on the wall behind counter top equipment taller than 16 inches. Wall protection behind mop sinks must cover the entire splash zone. Plastic coated hardboard is not acceptable. 15. All floors in the kitchen, food preparation, food service, food storage, and dishwashing areas must be surfaced with a durable, nonabsorbent, easily cleanable material. Expansion joints, seams, saw cuts and the like in all areas, including customer seating areas, must be filled and sealed so as to provide a smooth and cleanable surface. 16. The ceiling above the food preparation areas must be non -perforated, nonabsorbent, smooth and easily cleanable. 17. Cabinet shelving must be nonabsorbent, smooth and easily cleanable. (Self stick vinyl or other type surfaces are not acceptable) 18. All light fixtures in food preparation and storage areas must be provided with covers and shatterproof bulbs. 19. Plumbing must meet state and local codes. 20. It cannot be determined from the floor plan or information submitted whether or not a chemical dispensing system will be installed at the mop sink. Please note that the use of screw -on type 'wye' adaptors at the mop sink faucet for use with chemical dispensing systerns is prohibited. Additionally chemical dispensers cannot be connected to the mop sink faucet. The chemical dispenser must have a separate water connection. A 'sidekick' adaptor at the mop sink faucet is acceptable. 21. It is unclear as to the amount of dry storage area that will be provided. A dry storage area of sufficient size must be provided. The amount of dry storage area must be determined by one of the following methods and will be verified for amount at the preoperational inspection; a.) a floor space (and wall shelf) area equivalent to 25% of all the kitchen space, or b.) one square foot of space per customer seat. Public access to the dry storage area needs to be restricted. Subject: Proposed Gravity Bar, 610 5th Avenue South #B, Edmonds December 29, 2017 A preoperational inspection is required prior to operating permit issuance and approval to open for business. At the time of inspection the construction of the food service establishment must be complete and all equipment must be in place and in proper operating condition. Incomplete construction or equipment operation will result in a $185.00 re -inspection fee. Contact the Food Program office a minimum of one week in advance to schedule an appointment for the preoperational inspection. The preoperational inspection will ensure compliance with the Rules and Regulations of the State Board of Health for Food Service Sanitation. Changes or additions to the approved plans or equipment require pre -approval from the Snohomish Health District prior to implementation of the changes. Please contact me if you have any questions. My office number is 425.339.8742 and my email address is ehaaedorn(asnolid. ora. Sincerely, Elaine Hagedorn, RS Environmental Health Specialist Food Establishment Plan Review EH/kkc Enclosure: cc: City of Edmonds Building Department WA State Liquor Control Board Retta Taffesse RS, Environmental Health Specialist