Health District Approval Letter.pdfRobert Ho
321 Main Street
Edrnonds, WA 98020
Subject* Proposed Remodel Salt and Iron, 321 Main Street, Edmonds
Dear Mr. H'o:
Environmental Health Division
Your plans have been reviewed with the Rules and Regulations of the State Board of Health, and with the
policies of the Snohomish Health District. With the addition of the following conditions, the plans are
approved.
1. The conditional approval of the plans for Salt and Iron was based upon the plans submitted May
19, 2016, menu submitted June 11, 2016 and HACCP submitted June 10, 2015. Any changes to
the plans submitted May 19, 2016, menu submitted June 11, 2016 and HACCP submitted June 10,
2016 will void this approval.
2. It is understood that the scope of this remodel is for the expansion of Salt and Iron into the space
previously occupied by a retail meat establishment. Additional dining room space and a prep
kitchen, which will be used for low volume dessert preparation and as server station during over
flow periods, will result. The total seat count for Salt and Iron LLC wIJI increase to 51-150 seats.
The fee difference in seat count from 13-50 to 51-160 seats must be submitted prior to approval
to open.
3. Three -compartment sinks must be NSF or equivalent listed with integral drainboards at both ends. The
basins of the three -compartment sink must be large enough to fit the largest item needing to be washed.
4. An indirect waste drain (an air gap) is required for the food preparation sink, three -compartment sink,
ice machine, and any equipment in which food is placed. Please note that a direct drain to a grease trap
is not considered an indirect drain even if the grease trap is indirectly drained.
5. Each food preparation sink must be NSF or equivalent listed with at least one integral drainboard.
& Only one food preparation sink is indicated on the floor plan. Because of this only fruit/vegetable/ready-
to-eat
ruit/vegetable/ready-
to-eat food preparation will be allowed at this sink. No rinsing or thawing under running water of raw
meat, poultry, and/or seafood will be allowed without the installation of an additional and separate food
preparation sink. If installed, the location of any additional food preparation sink must be approved prior
to installation. The sink must be NSF listed or equivalent and have at least one integral drainboard.
7. A horizontal separation of at least 16 inches or a vertical partition 16 inches in height is required
between the handwash sink and all food preparation areas.
8. A horizontal separation of at least 16 inches or a vertical partition 16 inches in height is required
between the handwash sink and the food preparation sink and between the food preparation sink and
the three compartment sink.
9. Water heaters must be of sufficient size to provide hot water to dishwasher and/or scullery sinks and at
the same time provide hot water to all handwash sinks.
10. Hot water must be available to all handwash sinks within 15 seconds. The hot water for the facility must
not be used, at any plumbing fixture, for a minimum of 6 hours prior to the preoperational inspection.
This is required so that proper testing of the 15 -second time requirement for hot water availability can be
completed.
3020 Rucker Avenue, Suite 104 N Everett, WA 98201-3900 11 tel: 425.339.5250 M fax: 425.339.5254
Subject: Proposed Remodel Salt and Iron, 321 Main Street, Edmonds
June 12, 2015
Page 2
11. All food service equipment, both new and' used, must be listed by the National Sanitation Foundation
((TSF) or equivalent for its intended use. Used and new refrigeration must be capable of holding food: at
temperature of 41°F or below.
12. Used equipment is subject to onsite inspection to determine acceptability for use in the proposed food
service establishment. Used equipment must be clean, in proper operating condition, and in good repair.
Used refrigeration must be capable of holding at a temperature of 41 OF or below.
11 No manufacturer and/or model number was provided for the reach -in refrigeration and freezer units.
Prior to the request for the preoperational inspection, a manufacturer name and model number for the
reach -in refrigeration and freezer units must be submitted. The manufacturer and model number must
be found to be certified by NSF or equivalent. If verification of NSF or equivalent certification for the
reach -in refrigeration and freezer units cannot be given by the time of the request for a preoperational
inspection these units may not be approved for use in the proposed food establishment.
14. Extra wall protection is required on walls behind all sinks, including restroom handwash sinks, and food
preparation counters and tables. A 16 -inch high backsplash; of plastic laminate, fiberglass -reinforced
plastic or equal is acceptable. A backsplash higher than 16 inches is required on the wall behind counter
top equipment taller than 16 inches, Plastic coated hardboard is not acceptable.
15. All floors in the kitchen, food preparation, food service, food storage, and dishwashing areas must be
surfaced with a durable, nonabsorbent, easily cleanable material. Expansion joints, seams, saw cuts and
the like in concrete floors in all areas, including customer seating areas, must be filled and sealed so as
to provide a smooth and cleanable surface.
16. The ceiling above the food preparation areas must be non -perforated, nonabsorbent, smooth and easily
cleanable.
17. Cabinet shelving must be nonabsorbent, smooth and easily cleanable. (Self stick vinyl or other type
surfaces are not acceptable)
18. All light fixtures in food preparation and storage areas must be provided with covers and shatterproof
bulbs. Hot hold unit heat lamps must be provided with shatterproof bulbs.
19. If the establishment continues to be in operation during the remodel, dust barriers must be installed to
ensure that food protection and safety is not compromised. The establishment will be required to
discontinue operations if any disruption in water, electrical, or sewer service occurs, due to the remodel.
Proper handwash stations must be kept accessible and functional during all hours of food service
establishment operation.
20. Plumbing must meet state and local codes.
21. The ventilation system shall be installed and operated to meet applicable building,, mechanical, and fire
codes.
22. It is unclear as to the amount of dry storage area that will be provided. A dry storage area of sufficient
size must be provided. The amount of dry storage area must be determined by one of the following
methods and will be verified for amount at the preoperational inspection: a floor space (and wall shelf)
area equivalent to 25% of all the kitchen space, or one square, foot of space per customer seat.
A preoperational inspection is required prior to operating permit issuance and approval to open for
business. At the time of inspection the construction of the food service establishment must be complete and
all equipment must be in place and in proper operating condition. Incomplete construction or equipment
operation will result in a $168.00 re -inspection fee. Contact the Food Program office a minimum of one
week in advance to schedule an appointment for the preoperational inspection. The preoperational
inspection will ensure compliance with the Rules and Regulations of the State Board of Health for Food
Service Sanitation.
Subject: Proposed Remodel Salt and Iron, 321 Main Street, Edmonds
June 12, 2015
Page 3
Changes or additions to the approved plans or equipment require pre -approval from the Snohomish Health
District prior to implementation of the changes.
Please contact me if you have any questions. My office number is 425.339.8742 and my email address is
eha-gedorn@snohd.org,
Sincerely,.
o
El' Vine Hagedorn, RS
Environmental Health Specialist
Food Establishment Plan Review
EH/mem
Enclosure: Annual Food Establishment Permit Application, Fee Schedule
cc: City of Edmonds Building Department
WA State Liquor Control Board.