Hegyi1.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: October 5, 2007 TO: Atilla Hegyi st 19620 81 Place W Edmonds, WA 98026 FROM: Ann Bullis, Assistant Building Official RE: Plan Check # 2007-0795 Project: Hegyi Remodel/Addition st Project Address: 19620 81 Place W During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Provide written responses to each comment and where changes can be found on the plans. Please resubmit to Theresa Umbaugh, Permit Coordinator. 1.The structural calculations submitted with your 9/21/07 resubmittal must be stamped and signed by a State licensed Professional Engineer (IRC 106.1) and contain minimum design information per IBC Chapter 16. 2.As discussed at our meeting, please dimension the framing plan for the north half of the roof. Dimension the spans of all beams/headers and rafters, as well as the exterior walls (perimeter) of the building. Without this information the loads cannot be verified. Also, note the scale of the plan such as ¼” = 1 foot or 3/16” = 1 foot (currently it does not appear to be a recognized scale). This is required in the City’s Addition/Remodel handout previously provided to you. 3.Kitchen addition (see attached handout): a.As noted in the Building Official’s letter to you dated September 24, 2007, provide complete plans of the kitchen addition, including foundation, floor framing, elevation views, (roof framing already provided), and cross reference the building sections that you have drawn on the framing plans. Examples of plans and details can be found in the enclosed handout. b.Based on the section submitted for the Kitchen West Wall Load Path, the roof framing is non-conventional construction and does not meet the conventional provisions of IRC 802.3. Plans and structural calculations must be stamped and signed by a State licensed Professional Engineer. c.Complete the enclosed Energy Worksheets for the kitchen addition and note all insulation R-values and window U-values on the plans. If the addition cannot meet current energy code requirements, construction must be revised to accommodate the minimum insulation values, or energy calculations using the Component Performance approach (WSEC Chapter 5) must be provided. For example, 2x6 floor joists cannot hold R-30 batt insulation (minimum would be 2x10), however you may see if rigid insulation will meet this requirement. d.Based on the floor plan, walls do not minimum bracing requirements of IRC 602.10 (also see State Amendments). Lateral calculations must be stamped and signed by a State Licensed Professional Engineer. e.½” Anchor bolts must be spaced no more than 6’ o.c., located 12” of each end of each plate with minimum 7” embedment and 3”x3” washers. f.Specify thickness of wall and roof sheathing, as well as nail spacing. g.Note the kitchen addition on the site plan. h.Provide deck plans, including the roof cover over the deck. This must be included in this permit as well. See enclosed deck handout for minimum plans and details. 4.Specify post and beam connections. 5.All wood in contact with concrete must be pressure treated or naturally resistant to decay (such as foundation redwood). Revise plans to show this where ever new members are being added. IRC 319.1 Page 2 of 2