Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
HORTON AH SPEC SHEET.pdf
Submittal Variable Speed Convertible Air Handler 2 Ton TE M6AOB24H21 S Note: The TEM6 series air handler is designed for installation in a closet, utility room, alcove, basement, crawlspace or attic. These versatile units are applicable to air conditioning and heat pump applications. Several models are available to meet the specific requirements of the outdoor equipment. Field installed electric resistance heaters are available. TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. August 2015 TEM6A0B24-SUB-1A-EN CR)Jngersoll Rand Outline Drawing MINIMUM UNIT CLEARANCE TABLE TO COMBUSTIBLE SERVICE MATERIAL CLEARANCE f REOUIREDI (RECOMMENDED) SIDES 0" 2' FRONT 0" 21' BACK 0" 0' INLET DUCT 0" 1' OUTLET DUCT I'. N/A PRODUCT DIMENSIONS Air Handler Model A B C D E F H Flow Control Gas Line Braze TEM6AOB24H21SA 46.77 18.50 1 16.50 16.75 4.68 7.33 20.09 TXV 3/4 All dimensions are in inches TEM6A0B24-SUB-1A-EN Product Specifications MODEL TEM6AOB24H21SA RATED VOLTS/PH/HZ 208-230/1/60 RATINGS(a) See O.D. Specifications INDOOR COIL — Type Plate Fin Rows — F. P.I. 4 - 14 Face Area (sq. ft.) 3.44 Tube Size (in.) 3/8 Refrigerant Control TXV Drain Conn. Size (in.)(b) 3/4 NPT DUCT CONNECTIONS See Outline Drawing INDOOR FAN — Type Centrifugal Diameter -Width (In.) 10 X 8 No. Used 1 Drive - No. Speeds Direct - 16 CFM vs. in. w.g. See Fan Performance Table No. Motors — H.P. 1-1/3 Motor Speed R.P.M. Variable Volts/Ph/Hz 208-230/1/60 F.L. Amps 2.8 FILTER Filter Furnished? (c) No REFRIGERANT R-410A Ref. Line Connections Brazed Coupling or Conn. Size — in. Gas 3/4 Coupling or Conn. Size — in. Liq. 3/8 DIMENSIONS H x W x D Crated (In.) 48-1/4 x 22-1/2 x 25-1/2 Uncrated 46-3/4 x 18-1/2 x 21-1/8 WEIGHT Shipping (Lbs.) / Net (Lbs.) 126/117 (a) These Air Handlers are A.H.R.I certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data. (b) 3/4" Male Plastic Pipe (Ref: ASTM 1785-76) (U Remote filter required. TEM6A0B24-SUB-1 A -EN Minimum Airflow CFM TEM6AOB24H21S Heater Minimum Heater Airflow CFM With Heat Pump Without Heat Pump BAYHTR1504BRKC,BAYHTR1504LUGB BAYHTR1505BRKC,BAYHTR1505LUGB 550 600 BAYHTR1508BRKC,BAYHTR1508LUGB 800 600 BAYHTR1510BRKC,BAYHTR1510LUGB 825 700 BAYHTR1516BRKA 1050 850 BAYHTR351OLUGC 800 600 BAYHTR3515LUGC 900 850 TEM6AOB24H21 Airflow Performance with Auxiliary Heat Airflow Settings Dip Switch Settings Nominal Airflow See following tables for heater application: Switch 7 Switch 8 Low ON ON 601 - Pressure Drop for Electrical Heters Med-Lo OFF ON 723 - Minimum Heating 11 Med-Hi ON OFF 851 Airflow Matrix (on unit nameplates) High OFF OFF 973 TE M 6A0B24-SUB-1 A-E N Heater Pressure Drop Table Airflow CFM Number of Racks Heater Racks 1 2 3 4 Heater Model No. of Racks Air Pressure Drop - Inches W.G. BAYHTR1504 1 1800 0.02 0.04 0.06 0.14 BAYHTR1505 1 1700 0.02 0.04 0.06 0.14 BAYHTR1508 2 1600 0.02 0.04 0.06 0.13 BAYHTR1510 2 1500 0.02 0.04 0.06 0.12 BAYHTR1516 3 1400 0.02 0.04 0.06 0.12 BAYHTR3510 3 1300 0.02 0.04 0.05 0.11 BAYHTR3515 3 1200 0.01 0.04 0.05 0.10 BAYHTR1522 4 1100 0.01 0.03 0.05 0.09 BAYHTR1525 4 1000 0.01 0.03 0.04 0.09 900 0.01 0.03 0.04 0.08 800 0.01 0.03 700 0.01 0.02 600 0.01 0.02 Subcooling Adjustment System Matched with: Indoor Unit Model No. Outdoor Model No. Subcooling 16 SEER HP - 2 ton TEM6AOC36H31 4TWR60241-11000A 13 Degrees 4TWX6024HI000A 4A6H6024H1000A 15 SEER HP - 2 ton TEM6AOB24H21 4TWR5024GIO00A 14 Degrees TEM6AOB30H21 4A6H5024G1000A 15 SEER HP - 3 ton TEM6AOB301-121 4TWR5036G1000A 14 Degrees TEM6AOC36H31 4A6H5036G1000A TEM6AOC42H41 All other matches must be charged per the nameplate charging instructions TE M6A0 B24-SUB-1 A-E N Performance and Electrical Data Table 1. Air Flow Performance TEM6AOB24, TEM6AOB30 COOLING AIRFLOW PERFORMANCE, WET COIL, NO FILTER, NO HEATER OUTDOOR DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SPEED AIRFLOW AIRFLOW (TONS) SETTING SETTING SW1 SW2 SW3 SW4 POWER 0.1 0.3 0.5 0.7 0.9 LOW 353 CFM/ ON ON OFF ON CFM 533 497 461 425 390 ton Watts 52 78 104 130 157 1.5 NORMAL 401CFM/ ON ON OFF OFF CFM 611 580 548 517 486 ton Watts 65 95 125 155 185 HIGH 451CFM/ ON ON ON OFF CFM 684 668 644 611 570 ton Watts 81 115 148 182 215 LOW 343 CFM/ OFF ON OFF ON CFM 687 672 648 614 571 ton Watts 82 115 149 182 215 2 NORMAL 390 CFM/ OFF ON OFF OFF CFM 789 798 780 735 663 ton Watts 104 145 183 216 246 HIGH 439 CFM/ OFF ON ON OFF CFM 884 887 882 845 751 ton Watts 135 177 230 274 290 LOW 300 CFM/ ON OFF OFF ON CFM 752 749 729 691 636 ton Watts 92 123 167 211 241 2.5 NORMAL 340 CFM/ ON OFF OFF OFF CFM 859 861 863 830 727 ton Watts 128 172 211 242 268 HIGH 383 CFM/ ON OFF ON OFF CFM 963 973 995 967 844 ton Watts 172 223 263 291 308 LOW 323 CFM/ OFF OFF OFF ON CFM 959 962 974 940 816 ton Watts 169 217 263 297 311 3 NORMAL 367 CFM/ OFF OFF OFF OFF CFM 1097 1100 1100 1034 858 ton Watts 240 296 343 363 341 HIGH 413 CFM/ OFF OFF ON OFF I CFM 1192 1150 1115 1031 856 ton Watts 304 331 354 361 339 Table 2. Air Flow Performance TEM6AOB24, TEM6AOB30 HEATING AIRFLOW PERFORMANCE, NO FILTER, NO HEATER OUTDOOR DIP SWITCH SETTING EXTERNAL STATIC PRESSURE UNIT SIZE SPEED AIRFLOW AIRFLOW (TONS) SETTING SETTING SW1 SW2 SW3 SW4 POWER 0.1 0.3 0.5 0.7 0.9 LOW 394 CFM/ ON ON OFF ON CFM 599 571 539 502 462 ton Watts 58 88 117 146 175 NORMAL 448 CFM/ ON ON OFF OFF CFM 680 665 641 610 572 1.5 ton Watts 72 109 145 178 209 HIGH 493 CFM/ ON ON ON OFF CFM 748 746 682 545 326 ton Watts 89 118 163 208 240 LOW 393 CFM/ OFF ON OFF ON CFM 785 790 773 735 674 ton Watts 97 128 175 223 253 NORMAL 446 CFM/ OFF ON OFF OFF CFM 904 902 912 894 809 2 ton Watts 131 179 219 253 281 HIGH 491CFM/ OFF ON ON OFF CFM 980 972 990 974 863 ton Watts 167 216 268 308 324 LOW 350 CFM/ ON OFF OFF ON CFM 866 870 866 833 750 ton Watts 125 162 215 263 286 2.5 NORMAL 398 CFM/ ON OFF OFF OFF CFM 995 988 1005 986 872 ton Watts 171 222 271 309 325 HIGH 437 CFM/ ON OFF ON OFF CFM 1099 1086 1098 1065 918 ton Watts 220 274 328 362 353 LOW 338 CFM/ OFF OFF OFF ON CFM 1010 1001 1018 1000 888 ton Watts 174 224 275 315 331 3 NORMAL 384 CFM/ OFF OFF OFF OFF CFM 1154 1151 1135 1066 905 ton Watts 246 312 350 361 345 HIGH 422 CFM/ OFF OFF ON OFF CFM 1245 1167 1127 1067 927 ton Watts 305 322 346 361 352 TEM6A0B24-SUB-1 A -EN Performance and Electrical Data 1. See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters. 2. Heater model numbers may have additional suffix digits. Table 3. Electrical Data TEM6AOB24,TEM6AOB30 HEATER DATA 240 Volt 208 Volt No. of Capacity Heater Minimum Maximum Capacity Heater Minimum Maximum Heater Model No. Circuits/ Phases Amps per Circuit Overload Amps per Circuit Overload kW BTUH Circuit Ampacity Protection kW BTUH Circuit Ampacity Protection No Heater 2.8 * 4 15 2.8 * 4 15 BAYHTR1504BRKC 1/1 3.84 13100 16.0 24 25 2.88 9800 13.8 21 25 BAYHTR1504LUGB BAYHTR1505BRKC 1/1 4.80 16400 20.0 29 30 3.60 12300 17.3 25 25 BAYHTR1505LUGB BAYHTR1508BRKC 1/1 7.68 26200 32.0 44 45 5.76 19700 27.7 38 40 BAYHTR1508LUGB BAYHTR1510BRKC 1/1 9.60 32800 40.0 54 60 7.20 24600 34.6 47 50 BAYHTR1510LUGB BAYHBRKA 1 ((aa) ) Circuit it 1 2/1 9.60 32800 40.0 54 60 7.20 24600 34.6 47 50 BAYHTR1516BRKA Circuit 2 4.80 16400 20.0 25 25 3.60 12300 17.3 22 25 BAYHTR351OLUG 1/3 9.60 32800 23.1 32 35 7.20 24600 20.0 28 30 BAYHTR3515LUG 1/3 1 14.40 49100 34.6 1 46 50 1 10.80 36900 1 30.0 1 41 45 * = Motor Amps A MCA and MOP for circuit 1 contains the motor amps TE M6A0 B24-SUB-1 A-E N Features and Benefits • Painted metal cabinet with captured foil face insulation • 2% or less air leakage • R-4.2 Insulating Value • Multi -Position UP/Down Flow, Horizontal Left /Right • ALL Aluminum Coil with Enhanced Patented Coil Fin • Electric Heaters with polarized plug connections (sold as accessory) • R-410AThermal Expansion Valve ETA us [ISTEO Intertek • Variable Speed ECM Motor • Low Voltage Pigtail Connections • Draw Through Design • Horizontal Drain Pan • Single Color • Fused 24V Power • 1 year warranty • 10-year warranty registered • Optional extended warranty available The manufacturer optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, the manufacturer offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.IRCO.com. Them an ufacturer has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2014 Trane TEM SUB-1A-EN Aug 2015 Ingersoll Rand Supersedesrsedes TEM6A0624-SUB-1-EN (December2014) `i